Proportional Directional Control Valves
Catalog HY14-2550/US
D_1FL.indd, ddp
A70
Parker Hanniļ¬n Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
A
Electrical Speciļ¬cations Series D**FL
Application Guidelines
Supply Voltage V 12 to 28
Maximum Current A 3.5
Motion Proļ¬le Adjustment User set; potentiometers inside electronics enclosure.
Speed 0 to 100% valve opening; two speeds forward, two speeds retract.
Ramps (minimum limited by actual 0.025 to 15 seconds; one acceleration, two deceleration adjustments.
valve step response) Shared both forward/retract.
Test Points Inside electronics enclosure.
V1, V2, V3, V4 0 to 5 volts, corresponding to 0 to 100% valve opening, or speed.
R1, R2, R3 0 to 5 volts, corresponding to 0.025 to 15 seconds ramp time.
Logic Interface
Ordering code ļ¬eld: Electrical variation W T
(options available all valve sizes)
Electrical Isolation DC Optical-Coupled AC Optical-Coupled
Polarity Signal pins A, C & E; referenced to Signal pins A, C & E; referenced to
0V pins B, D & F respectively. AC neutral pins B, D & F respectively.
Input Impedance ohms >2000 >2000
Input Voltage, Absolute Max. V 28 VDC 130 VAC
Logic āonā (1), Min. Voltage V >9.6 VDC >96 VAC
Logic āonā (1), Current mA 3.2 mA 3.2 mA
Logic āoffā (0), Min. Voltage V <6.0 VDC <51 VAC
Logic āoffā (0), Current mA 3.2 mA 3.2 mA
Mating Connectors (order separately)
Power Supply Connector Part # 1210292 (4-pin MS)
Logic Input Connector Part # MS3106E-14S-6S (6-pin MS)
The D**FL series proportional valves accept discrete
on/off logic signals which trigger simple motion proļ¬les
controlling actuator speed, acceleration, and decel-
eration. All motion control potentiometer adjustments
and jumper headers are located inside the electronics
enclosure. Two modes of operation are user select-
able by a jumper setting (JP1): āMotion Proļ¬lerā or āSlow
Shiftā. The āMotion Proļ¬lingā mode provides two-speed
velocity control typically used in rapid traverse and
feed circuits. The āSlow Shiftā provides single velocity
control. Both modes allow individual speed adjustment
for actuator extend and retract. Ramp adjustments for
extend and retract proļ¬les are shared.
Refer to Interface and Motion Proļ¬le diagrams on
the following pages.
Both DC and AC voltage logic interfaces are available.
Refer to ordering code ļ¬eld āElectronic Variationā and
the technical data sheet for more information. Note that
the interface connections are polarity sensitive. Refer
to the block diagram and technical speciļ¬cations.
Refer to the Installation Guide for set-up, conļ¬guration,
and application guidelines (packaged with each valve):
D1FL: Installation Guide Bulletin 2589-M2/USA
D3FL: Installation Guide Bulletin 2589-M3/USA
D41FL,
D91FL: Installation Guide Bulletin 2589-M1/USA