Catalog HY15-3502/US
Parker Hannifin Corporation
Hydraulic Cartridge Systems
23
Pressure Comp. Proportional Poppet Valve
Series FAPC101N
Load Pressure
140
2000
70
1000
Bar
PSI
0
210
3000
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
0
3
15 57.0
34.0
45.4
22.7
11.4
Flow
9
12
GPM LPM
6
Pressure Compensation of Regulated Flow
Input Current (%) 100 Hz PWM
40
60 70
20
0
80
0
6
3
34.0
22.7
11.4
9
15 57.0
45.412
GPM LPM
Flow
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
Flow vs. Input Current
(3)
(2)
(1)
(2)
(3)
Note: Always connect Port (3)
to Port (1) through .031 orifice.
For FAPC101 only.
Check
Valves
Shuttle
Valves
Load/Motor
Controls
Flow
Controls
Pressure
Controls
Logic
Elements
Directional
Controls
Manual
Valves
Solenoid
Valves
Proportional
Valves
Coils &
Electronics
Bodies &
Cavities
Technical
Data
SH
CV
LM
FC
PC
LE
DC
MV
SV
PV
CE
BC
TD
Technical Information
Rated Flow 38 LPM (10 GPM)
De-Energized
at P 34.5 Bar
(500 PSI)
Maximum Input 210 Bar (3000 PSI)
Pressure at
Port 2
Minimum Pressure 34 Bar (500 PSI)
Differential
Maximum Internal 5 drops/min. (.33 cc/min.)
Leakage @ 210 Bar (3000 PSI)
Hysteresis @ <10%
100 Hz PWM NOTE: Current regulated
PWM recommended
Cartridge Material All operating parts
hardened steel.
Operating Temp. -45°C to +93.3°C (“D”-Ring)
Range/Seals (-50°F to +200°F)
-34°C to +121°C (Nitrile)
(-30°F to +250°F)
-26°C to +204°C (Fluorocarbon)
(-15°F to +400°F)
Fluid Mineral-based or synthetic with
Compatibility/ lubricating properties at viscosities
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
Filtration ISO Code 18/16/13,
SAE Class 4
Approx. Weight .24 kg (.53 lbs.)
Cavity 3X
(See BC Section for more details)
General Description
2 Way, Normally Open, Proportional Poppet Valve with
Pressure Compensation. For additional information
see Technical Tips on pages PV1-PV6.
Features
Low leakage poppet design with no dynamic seal to wear
out on the compensator
Adjusted at factory for low variation
Coil: Waterproof, hermetically sealed, requires no
O’Rings; Symmetrical coil can be reversed without
affecting performance.
External surfaces plated
Excellent low flow metering capability
Performance Curves
Specifications
All performance data with CAS coil.
Maximum current, 70% recommended.
Hydraulic oil 150 SSU @ 40°C (32 cSt)
Catalog HY15-3502/US
Parker Hannifin Corporation
Hydraulic Cartridge Systems
Pressure Comp. Proportional Poppet Valve
Series FAPC101N
24
22.0
(0.86)
36.0
(1.43)
66.5
(2.62)
XXVDC XXW
CAX XXX H
PAT.XXXXXXX
MADEINU.S.A.
53.3
(2.10)
69.6
(2.74)
145.1
(5.71)
50.0
(1.97)
25.4
(1.00)
12.0
(.47)
(1)
(3)
(2)
7/8-14UNF-2A
Thread
1" Hex.
34 Nm (25 lb. ft.)
Torque
See Super Coil
5/8" I.D.
Information For
Te rminal Connectors
NOTE: Requires 3X Cavity
Always connect Port (3) to Port (1)
through .031 orifice.
Check
Valves
Shuttle
Valves
Load/Motor
Controls
Flow
Controls
Pressure
Controls
Logic
Elements
Directional
Controls
Manual
Valves
Proportional
Valves
Coils &
Electronics
Technical
Data
SH
CV
LM
FC
PC
LE
DC
MV
SV
PV
CE
BC
TD
Bodies &
Cavities
Solenoid
Valves
Technical Information
Coil
Type
Coil
Termination
Coil
Voltage
FAPC101
10 Size
Proportional
Valve
Style
Code Style
N Normally Open
Dimensions
Millimeters (Inches)
Ordering Information
Code Seals / Kit No.
Omit “D”-Ring / (SK10-3S)
N Nitrile / Buna-N (Std.)
(SK10-3XN)
V Fluorocarbon /
(SK10-3XV)
Seals
N
Body
Material
Port
Size
Code Port Size Body Part No.
Omit Cartridge Only
8T SAE-8 (B10-3X-*8T)
Code Body Material
Omit Steel
A Aluminum
Code Coil Voltage
Omit Without Coil
D012 12 VDC
D024 24 VDC
Code Coil Termination
Omit Without Coil
D DIN Plug Face
A Amp Jr. Timer*
S Dual Spade*
W Dual Screw*
L Dual Lead Wire*
H Molded Deutsch*
PF Dual Lead Wire with
Packard Female Weather
Pack Connector
1201 5792*
PM Dual Lead Wire with
Packard Male Weather
Pack Connector
1201 0973*
See Super Coil 5/8 I.D.
*DC Only
Code Coil Type
Omit Without Coil
SS Super Coil - 18 Watts
* Add “A” for aluminum, omit for steel.
Body includes orifice and port