Catalog HY15-3502/US
Parker Hannifin Corporation
Hydraulic Cartridge Systems
23
Pressure Comp. Proportional Poppet Valve
Series FAPC101N
Load Pressure
140
2000
70
1000
Bar
PSI
0
210
3000
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
0
3
15 57.0
34.0
45.4
22.7
11.4
Flow
9
12
GPM LPM
6
Pressure Compensation of Regulated Flow
Input Current (%) 100 Hz PWM
40
60 70
20
0
80
0
6
3
34.0
22.7
11.4
9
15 57.0
45.412
GPM LPM
Flow
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
Flow vs. Input Current
Note: Always connect Port (3)
to Port (1) through .031″ orifice.
For FAPC101 only.
Check
Valves
Shuttle
Valves
Load/Motor
Controls
Flow
Controls
Pressure
Controls
Logic
Elements
Directional
Controls
Manual
Valves
Solenoid
Valves
Proportional
Valves
Coils &
Electronics
Bodies &
Cavities
Technical
Data
SH
CV
LM
FC
PC
LE
DC
MV
SV
PV
CE
BC
TD
Technical Information
Rated Flow 38 LPM (10 GPM)
De-Energized
at ∆P 34.5 Bar
(500 PSI)
Maximum Input 210 Bar (3000 PSI)
Pressure at
Port 2
Minimum Pressure 34 Bar (500 PSI)
Differential
Maximum Internal 5 drops/min. (.33 cc/min.)
Leakage @ 210 Bar (3000 PSI)
Hysteresis @ <10%
100 Hz PWM NOTE: Current regulated
PWM recommended
Cartridge Material All operating parts
hardened steel.
Operating Temp. -45°C to +93.3°C (“D”-Ring)
Range/Seals (-50°F to +200°F)
-34°C to +121°C (Nitrile)
(-30°F to +250°F)
-26°C to +204°C (Fluorocarbon)
(-15°F to +400°F)
Fluid Mineral-based or synthetic with
Compatibility/ lubricating properties at viscosities
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
Filtration ISO Code 18/16/13,
SAE Class 4
Approx. Weight .24 kg (.53 lbs.)
Cavity 3X
(See BC Section for more details)
General Description
2 Way, Normally Open, Proportional Poppet Valve with
Pressure Compensation. For additional information
see Technical Tips on pages PV1-PV6.
Features
•
Low leakage poppet design with no dynamic seal to wear
out on the compensator
•
Adjusted at factory for low variation
•
Coil: Waterproof, hermetically sealed, requires no
O’Rings; Symmetrical coil can be reversed without
affecting performance.
•
External surfaces plated
•
Excellent low flow metering capability
Performance Curves
Specifications
All performance data with CAS coil.
Maximum current, 70% recommended.
Hydraulic oil 150 SSU @ 40°C (32 cSt)