Catalog HY15-3502/US
Parker Hannifin Corporation
Hydraulic Cartridge Systems
13
Proportional Poppet Valve
Series FAP121N
Flow (Q)
56.3
15
75.7
20
93.8
25
18.8
5
37.8
10
LPM
GPM
0
113.6
30
0
200
100
20.7
13.8
6.89
300
500 34.5
27.6400
PSI Bar
Pressure Drop ( P)
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
Pressure Drop vs. Flow (Through cartridge only)
De-Energized
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
0
10
60 227
114
151
189
75.7
37.9
Flow
30
40
50
GPM LPM
20
Current (%)
6020 40
0
80
Flow vs. Input Current
At Various
Differential Pressures
250 PSI
500 PSI
1500 PSI
3000 PSI
Check
Valves
Shuttle
Valves
Load/Motor
Controls
Flow
Controls
Pressure
Controls
Logic
Elements
Directional
Controls
Manual
Valves
Solenoid
Valves
Proportional
Valves
Coils &
Electronics
Bodies &
Cavities
Technical
Data
SH
CV
LM
FC
PC
LE
DC
MV
SV
PV
CE
BC
TD
Technical Information
Rated Flow 98.5 LPM (26 GPM)
De-Energized
at ∆P 34.5 Bar
(500 PSI)
Maximum Input 210 Bar (3000 PSI)
Pressure at
Port 2
Minimum Pressure 21 Bar (300 PSI)
Differential
Maximum Internal 5 drops/min. (.33 cc/min.)
Leakage @ 210 Bar (3000 PSI)
Hysteresis @ <15%
100 Hz PWM NOTE: Current regulated
PWM recommended
Cartridge Material All operating parts
hardened steel.
Operating Temp. -34°C to +121°C (Nitrile)
Range/Seals (-30°F to +250°F)
-26°C to +204°C (Fluorocarbon)
(-15°F to +400°F)
Fluid Mineral-based or synthetic with
Compatibility/ lubricating properties at viscosities
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
Filtration ISO Code 18/16/13,
SAE Class 4
Approx. Weight .31 kg (.68 lbs.)
Cavity C12-2F
(See BC Section for more details)
General Description
2 Way, Normally Open, Proportional Poppet Valve.
For additional information see Technical Tips on
pages PV1-PV6.
Features
•
Adjusted at factory for low variation
•
Coil: Waterproof, hermetically sealed, requires no
O’Rings; Symmetrical coil can be reversed without
affecting performance.
•
Industry common cavity
•
External surfaces plated
•
Excellent low flow metering capability
Performance Curves
Specifications
All performance data with CAS coil.
Maximum current, 70% recommended.
Hydraulic oil 150 SSU @ 40°C (32 cSt)