General
Design Directional spool valve, sandwich type
Actuation Solenoid
Size DIN NG06 / CETOP 03 / NFPA D03
Mounting interface DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -20...+60
MTTF
D
value [years] 150
Weight [kg]
[kg]
1.8 (1 solenoid), 2.3 (2 solenoids) w/o position control
2 with position control
Hydraulic
Max. operating pressure [bar] P, A B: 350 ; T: 210
Fluid Hydraulic oil in accordance with DIN 51524
Fluid temperature [°C] -20…+70 (NBR: -25…+70)
Viscosity, permitted [cSt] / [mm²/s] 20...400
recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow max. [l/min] 50
Leakage at 50 bar [ml/min] Up to 10 per flow path, depending on spool
Static / Dynamic
Step response at 95 % [ms] Energized: 32 ; De-energized: 40
Electrical characteristics
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Max. switching frequency [1/h] 15000
Protection class IP 65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code K J U G
Supply voltage [V] 12 V = 24 V = 98 V = 205 V =
Tolerance supply voltage [%] ±10 ±10 ±10 ±10
Current consumption [A] 2.72 1.29 0.33 0.13
Power consumption [W] 32.7 31 31.9 28.2
Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461.
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
Technical Data