436 437
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK/icountPD
Diagnostic Self Check Start-up Time:
Customerselectable5-900seconds
Measurement Period:
5to180seconds
Reporting interval through RS232:
0 to 3600 seconds
Digital -/LED display update time:
Every second
Limit Relay Output:
Changesoccur+/-1ISOcodeatsetlimit(HysteresisON)orcustomer
set (Hysteresis OFF)
Particle / % RH Output Signal:
Continuous
Principle of operation:
Laser diode optical detection of actual particulates
International Codes:
ISO7–22,NAS0–12
Calibration:
By recognised online methods confirmed by the relevant ISO proce-
dures
MTD–ViaacertiedprimaryISO11171automaticparticledetector
usingISO11943principles,withparticledistributionreportingtoISO
4406:1996
ACFTD–ConformingtoISO4402principleswithparticledistribution
reportingtoISO4406:1996
Recalibration:
ContactParkerHannin
Performance:
+/-1ISOCode(Dependantonstabilityofow)
Reproducibility / Repeatability:
Betterthan1ISOCode
Power Requirement:
Regulated9to40Vdc
Current Rating:
Typically120mA
Hydraulic Connection:
MineralM16x2testPoints
Aggressive:5/8”BSFtestPoints
Fuel:NotestPoints1/8BSP(Female)Ports(Plugged)
Required Flow Range through the icountPD:
40to140ml/min(OptimumFlow=60ml/min)
Online Flow Range via System 20 Inline Sensors (Hydraulic
systems only):
Size0=6to25l/min-(OptimumFlow=15l/min)
Size1=24to100l/min-(OptimumFlow=70l/min)
Size2=170to380l/min-(OptimumFlow=250l/min)
Required Differential Pressure across Inline Sensors:
0.4 bar (Minimum)
Viscosity Range:
1-500cSt
Temperature:
Ambientstoragetemperature -20°Cto+40°C(-4°Fto+104°F)
Environmentoperatingtemperature +5°Cto+60°C(+41°Fto+140°F)
Fluidoperatingtemperature +5°Cto+80°C(+41°Fto+176°F)
Working pressure:
2to420bar(30-6000PSI)
Moisture sensor calibration (Not offered with the fuel version):
±5%RH(overcompensatedtemperaturerangeof+10°Cto+80°C)
(+50°Fto+176°F)
Operating humidity range:
5%RHto100%RH
Moisture sensor stability:
±0.2%RHtypicalat50%RHinoneyear
Certification:
IP66rated.RefertotheECDeclarationofConformity.
EMC/RFI – EN61000-6-2:2001
EN61000-6-3:2001
Materials:
User friendly Abs construction.
Stainless Steel hydraulic block.
Dimensions:
182mmx155mmx86mm(7.2”x6.1”x3.4”)
Weight:
1.3kg(2.9lb)
Seals:
Mineral: Fluorocarbon. Aggressive: EPDM. Fuel: Fluorocarbon.
Computer Compability:
Parkerrecommendstheuseofa9-wayD-typeconnector.Thiscanbe
connectedtoaUSBportusingaUSB-serialadaptor.Notethatthese
connectors/adaptorsareNOT supplied with icountPD units: contact
Parker Hannifin for advice.
icountPD
Online Particle Detector
Features & Benefits
icountPD for use with aviation fuels
Field Data - Major International Airport
First 3 measurements represent fuel
from a previous cargo followed by a
regular clean delivery, thus demonstrating
the range of fuel cleanliness being
experienced at this particular location.
>4µ >6µ >14µ >21µ
Test 1 81058.3 62126.1 17817.6 6066.2
Test 2 87834.5 74763.0 35454.1 18044.4
Test 3 51383.4 32796.9 4424.8 1213.4
Test 4 1593.3 422.7 9.6 1.7
>4µ >6µ >14µ >21µ
Test 5 1226.1 261.5 2.4 0.4
Test 6 1085.7 210.9 1.3 0.1
Test 7 1037.9 198.7 1.3 0.1
icountPD for use with aviation fuels