436
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK/icountPD
Independent
monitoring of system
contamination trends
The icountPD Particle Detector
from Parker represents the most
up to date technology in particle
detection. The design dynamics,
attention to detail and moulding
compactness of the permanently
mounted, on-line particle detector
module, combined with on-board,
laser based, leading-edge
technology, brings to all industries a
truly revolutionary, particle detector
as a remarkable cost effective
market solution to fluid management
and contamination control.
icountPD
Online Particle Detector
For mineral oil, aggressive fluids or fuels
(ATEX approved version available. See page 476)
Contact Information:
Parker Hannifin
Hydraulic Filter Division Europe
European Product
Information Centre
Freephone: 00800 27 27 5374
(from AT, BE, CH, CZ, DE, EE, ES,
FI, FR, IE, IT, PT, SE, SK, UK)
filtrationinfo@parker.com
www.parker.com/hfde
Product Features:
• Independent monitoring of
system contamination trends.
• Warning LED or digital display
indicators for Low, Medium
and High contamination levels.
• Visual indicators with power
and alarm output warnings.
• Moisture%RHindicator
(optional).
• Costeffectivesolutionto
prolong fluid life and reduce
machine downtime.
• MI28pinorDeutsch
Connectoroptions.
• Continuousperformancefor
prolonged analysis.
• Fuel, Hydraulic and phosphate
Ester fluid compatible
construction.
• Self diagnostic software.
• FullPC/PLCintegration
technologysuchas:-RS232
and0-5Volt,4-20mA,
CAN(J1939)(ContactParker
for other options).
• Set up and Data logging
support software included.
icountPD for mineral oil applications
436 437
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK/icountPD
Diagnostic Self Check Start-up Time:
Customerselectable5-900seconds
Measurement Period:
5to180seconds
Reporting interval through RS232:
0 to 3600 seconds
Digital -/LED display update time:
Every second
Limit Relay Output:
Changesoccur+/-1ISOcodeatsetlimit(HysteresisON)orcustomer
set (Hysteresis OFF)
Particle / % RH Output Signal:
Continuous
Principle of operation:
Laser diode optical detection of actual particulates
International Codes:
ISO7–22,NAS0–12
Calibration:
By recognised online methods confirmed by the relevant ISO proce-
dures
MTD–ViaacertiedprimaryISO11171automaticparticledetector
usingISO11943principles,withparticledistributionreportingtoISO
4406:1996
ACFTD–ConformingtoISO4402principleswithparticledistribution
reportingtoISO4406:1996
Recalibration:
ContactParkerHannin
Performance:
+/-1ISOCode(Dependantonstabilityofow)
Reproducibility / Repeatability:
Betterthan1ISOCode
Power Requirement:
Regulated9to40Vdc
Current Rating:
Typically120mA
Hydraulic Connection:
MineralM16x2testPoints
Aggressive:5/8”BSFtestPoints
Fuel:NotestPoints1/8BSP(Female)Ports(Plugged)
Required Flow Range through the icountPD:
40to140ml/min(OptimumFlow=60ml/min)
Online Flow Range via System 20 Inline Sensors (Hydraulic
systems only):
Size0=6to25l/min-(OptimumFlow=15l/min)
Size1=24to100l/min-(OptimumFlow=70l/min)
Size2=170to380l/min-(OptimumFlow=250l/min)
Required Differential Pressure across Inline Sensors:
0.4 bar (Minimum)
Viscosity Range:
1-500cSt
Temperature:
Ambientstoragetemperature -20°Cto+40°C(-4°Fto+104°F)
Environmentoperatingtemperature +5°Cto+60°C(+41°Fto+140°F)
Fluidoperatingtemperature +5°Cto+80°C(+41°Fto+176°F)
Working pressure:
2to420bar(30-6000PSI)
Moisture sensor calibration (Not offered with the fuel version):
±5%RH(overcompensatedtemperaturerangeof+10°Cto+80°C)
(+50°Fto+176°F)
Operating humidity range:
5%RHto100%RH
Moisture sensor stability:
±0.2%RHtypicalat50%RHinoneyear
Certification:
IP66rated.RefertotheECDeclarationofConformity.
EMC/RFI – EN61000-6-2:2001
EN61000-6-3:2001
Materials:
User friendly Abs construction.
Stainless Steel hydraulic block.
Dimensions:
182mmx155mmx86mm(7.2”x6.1”x3.4”)
Weight:
1.3kg(2.9lb)
Seals:
Mineral: Fluorocarbon. Aggressive: EPDM. Fuel: Fluorocarbon.
Computer Compability:
Parkerrecommendstheuseofa9-wayD-typeconnector.Thiscanbe
connectedtoaUSBportusingaUSB-serialadaptor.Notethatthese
connectors/adaptorsareNOT supplied with icountPD units: contact
Parker Hannifin for advice.
icountPD
Online Particle Detector
Features & Benefits
icountPD for use with aviation fuels
Field Data - Major International Airport
First 3 measurements represent fuel
from a previous cargo followed by a
regular clean delivery, thus demonstrating
the range of fuel cleanliness being
experienced at this particular location.
>4µ >6µ >14µ >21µ
Test 1 81058.3 62126.1 17817.6 6066.2
Test 2 87834.5 74763.0 35454.1 18044.4
Test 3 51383.4 32796.9 4424.8 1213.4
Test 4 1593.3 422.7 9.6 1.7
>4µ >6µ >14µ >21µ
Test 5 1226.1 261.5 2.4 0.4
Test 6 1085.7 210.9 1.3 0.1
Test 7 1037.9 198.7 1.3 0.1
icountPD for use with aviation fuels
438
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK/icountPD
Dimensions / Installation Details
Typical Applications
Mobile Equipment
o Earth Moving Machinery
o Harvesting
o Forestry
o Agriculture
Monitoring of the hydraulics, enabling the vehicles
to function to their best capability under load
conditions through pistons, servo valves, control
rams and gear pumps.
Industrial Equipment
o Production Plants
o Fluid Transfers
o Pulp & Paper
oRefineries
To monitor the cleanliness of the equipment
throughout the production line, from the machine
tool controlled hydraulics through to contamination
of fluid transfer. Ensuring the integrity of the fluid is
maintained throughout the refining process.
Power Generation
o Wind Turbines
oGearboxes
o Lubrication Systems
With continuous monitoring the optimum level is
achieved in the least amount of time.
Maintenance
oTestRigs
o Flushing Stands
To increase efficiency of your equipment by
continuously monitoring the cleanliness level of the
hydraulic fluid.
Fuel Contamination Detection
o Fuel Storage Tanks
o Vehicle fuel tanks
o Uploading fuel into an aircraft
24/7detectionofparticulatelevelsinmostfuels
includingaviationfuel-JetA-1fuelspecification.
Maximum Torque 5Nm
438 439
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK/icountPD
Variable mA output settings
4-20mA output settings
ISO Setting
mAcurrent=(ISOCode/2)+4 eg.10mA=(ISO12/2)+4
or
ISOCode=(mAcurrent-4)*2 eg.ISO12=(10mA-4)*2
NAS Setting
mAcurrent=NASCode+5 eg.15mA=NAS10+5
or
NASCode=mAcurrent-5 eg.NAS10=15mA–5
The following table can be used to equate the analogue
outputtoanISOorNASCode.
ExampleISOcode12isequalto10mA
4.0
4.5
5.0
5.5
6.0
6.5
7.0
7.5
8.0
8.5
9.0
9.5
10.0
10.5
11.0
11.5
12.0
12.5
13.0
13.5
14.0
14.5
15.0
15.5
16.0
16.5
17.0
17.5
18.0
18.5
19.0
19.5
20.0
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
**
**
**
**
**
**
**
**
OVERRANGE
OVERRANGE
ERROR
mA ISO
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
00
0
1
2
3
4
5
6
7
8
9
10
11
12
**
**
ERROR
mA NAS
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
20 19 18 17 16 15 14 13 12 11 5 6 7 8 9 10 4 3 2 1 0 21
ISO CODE
Milliamp
O
utput
ISO V Output mA
0
2
4
6
8
10
12
14
16
18
20
13 12 11 5 6 7 8 9 10 4 3 2 1 0
NAS CODE
Milliamp
O
utput
NAS V Output mA
The following table can be used to equate the
analogueoutputtoanISOorNASCode.
ExampleISOcode12isequalto10mA
Variable voltage output settings
The variable voltage output option has the capability of two different voltage ranges: a 0–5Vdc range as
standard, and a user-selectable 0–3Vdc range. The ‘Full list of commands’ on how to change the voltage
output, are available from Parker.
ThefollowingtablescanbeusedtorelatetheanalogueouptuttoanISOorNAScode.
Forexample,ina0–5Vdcrange,ISOcode16isequaltoanoutputof3.5Vdc.Ina0–3Vdcrange,ISOcode8
isequaltoanoutputof1.0Vdc.
ISO Err
0–5Vdc
0–3Vdc
<0.2
<0.15
0
0.3
0.2
1
0.5
0.3
2
0.7
0.4
3
0.9
0.5
4
1.1
0.6
5
1.3
0.7
6
1.5
0.8
7
1.7
0.9
8
1.9
1.0
9
2.1
1.1
10
2.3
1.2
11 >
2.5
1.3
Table relating ISO codes to Voltage output
cont.
ISO 12
0–5Vdc
0–3Vdc
2.7
1.4
13
2.9
1.5
14
3.1
1.6
15
3.3
1.7
16
3.5
1.8
17
3.7
1.9
18
3.9
2.0
19
4.1
2.1
20
4.3
2.2
21
4.5
2.3
22
4.7
2.4
Err
>4.8
>2.45
NAS Err
0–5Vdc
0–3Vdc
<0.4
<0.2
00 0
0.6
N.S.
1
0.9
0.3
2
1.2
0.5
3
1.5
0.7
4
1.8
0.9
5
2.1
1.1
6
2.4
1.3
7
2.7
1.5
8
3.0
1.7
9
3.3
1.9
10
3.6
2.1
11 12 Err
3.9
2.3
4.2
2.5
4.5
2.7
>4.6
>2.8
Table relating NAS codes to Voltage output
440
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK/icountPD
Digital display parameters (ISO 4406/NAS 1638)
Digital display indication
The digital display will show the actual measured codes, the channel (µ) size and the user definable limits.
Notethatthechannelsizeandlimitsaredisplayedalternately.
TheMoistureSensorreading(%RH)willalsobeshown–iftheMoistureSensoroptionisfitted.
The order of trigger for both the codes and Moisture Sensor option is:
• Soliddigit(s)=code(s)thatareatorbelowthesetpoint(limit)
• Flashingdigit(s)=code(s)thatareabovethesetpoint(limit)
ThedisplayforISO4406andNAS1638areidentical.
Error detection:
In the unlikely event of a error occurring, the digital display on the icountPD will simply display the actual
errorcodeonly–i.e.ERROR13(AfulllistoferrorcodesaredetailedintheicountPDUserManual).
Channelsizes/Limits
Automatic light sensor
(c) MTD calibrated
Measured ISO codes
%RHMoisturesensorreading
Saturation 4–20mA 0–3Vdc 0–5Vdc
4.8
8
12
16
20
0.15
0.75
1.50
2.25
3.00
0.25
1.25
2.50
3.75
5.00
Start up
1. OncetheicountPDhasbeenconnectedtoaregulatedpowersupply,theproductlogoisdisplayedfor
approximatelyfivesecondsastheicountPDperformsaselfsystemdiagnosticcheck.
2. TheicountPDthenautomaticallystartsmonitoringusingfactorydefaulttestparameters.
Moisture sensor output settings
The Moisture Sensor is an option that can be included when ordering the icountPD.
The Moisture Sensor reports on the saturation levels of the fluid passing through the icountPD sensing cell.
Theoutputisalinearscale,reportingwithintherangeof5%saturationto100%saturation.
Table relating Saturation levels in the sensing cell to icountPD outputs
icountPD
Online Particle Detector
5%
25%
50%
75%
100%
Notes:ISO17/16/14and
MS=43%RHiffitted
440 441
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK/icountPD
Flow control ACC6NN019
A pressure compensated, flow control device
(ParkerHannifinpartnumberACC6NN019)
has been develop to give the icount PD greater
flexibility.
The flow control device enables testing where flow
ranges are out side the icountPD specification i.e.
(40–140ml/min),orwherepipediametersdonot
allow the icountPD to be installed.
The flow control device fits onto the downstream
(outlet)sideoftheicountPD.A06LEO24deg
cone and hydraulic adaptor is supplied which
enables connection directly to the icountPD.
Alternatively the flow control device can be fitted
further down stream.
The compact design requires no setting up or
further user intervention as long as the system
conditions remain within the recommended
pressure and viscosity ranges as below.
icountOS – Oil Sampler (IOS)
• Newandunderdevelopmentinthedetectionof
contaminates distribution in various Aviation fuels.
• Portable monitoring tool providing fluid
qualificationtoISO4406:1999standards.
• SupplementstheicountLCM20andACM20
product portfolio.
• Quick, simple to use monitoring tool for sampling
fluids from containers, fuel bunkers and holding
tanks.
• Field solution to Laboratory methods for the
detection of solid contamination and free water
inference.
P/NACC6NN019
Working pressure range 10to300bar
Differential pressure range 10to300bar
Working viscosity range 10to150Cst
442
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK/icountPD
Hydraulic Connection Diagram Dimensions
Flow Control Actuator Specification (P/N S840074)
Operation Manual flow rate adjustable via control knob
Mounting Type 4 off mounting holes to suit M6 screws (not supplied)
Mounting position Any
Weight 1.7kg(3.7lb)
Fluid Temperature 5°Cto+80°C(+41°Fto176°F)
Ambient storage temperature -20°Cto+40°C(-4°Fto+104°F)
Viscosity range 20cStto500cSt(Iflowerthan20cStcontactParker)
Differential pressure range 5to315bar
Maximum pressure 315bar
Flow direction ‘IN’to‘OUT’flowcontrolfunction
Port thread detail 1/8”BSPP(testpointsnotsupplied)
Internal Seals Fluoroelastomer
2 bar check valve
To Atmosphere
icountPD
P1P2
High Pressure
Line Side
Low Pressure
ReturnSide
OutIn
Actuator
90.0
20.0
78.2
113.2
58.2
78.2
46.5
50.0
G1/8portseitherside
of mounting block
“In”
4 holes 6.60 Thro’
“Out”
38.0Ctrs
62.0
80.0Ctrs
49.2
icountPD
Online Particle Detector
This application shows uploading
fuel into an aircraft with the
icountPD in use to monitor as a
‘go/nogo’device.
442 443
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK/icountPD
Communication Protocol
Communication Options
The icountPD may be configured using the icountPD Setup Utility. For more direct control of the device using its
communications protocol, you may also use the Microsoft Windows
®
HyperTerminal program, but note that this
program is not currently supplied with the Windows Vista
operating system. These two ways of communicating
with icountPD are described in the following section.
TheCommunicationprotocolfortheserial
communication link is to be used with Microsoft
Windows HyperTerminal. The settings are as follows:
Baudrate 9600
Databits 8
Parity None
Stopbits 1
Flowcontrol None
The commands used with this product are made up
ofRead,SetandStart/Stopcommands.
• Setcommandsallowthevalueorvaluesof
parameters to be set
• Readcommandsallowthevalueorvaluesor
parameters to be read
• Start/Stopallowstheusertostartandstoptests.
Example:
[SDFdd/mm/yy]-setsthedateformat.
[RDF]-readstheproductdateformat.
AllcommandsaresentinASCIIcharacters,and
the protocol accepts both upper and lower case
charactersastheexamplesbelow:
SDF
SdF
Note:Afulllistofcommandsaredetailedintheuser
manual
icountPD Setup Utility software (supplied)
444
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK/icountPD
No
Ordering Information
Part number Fluid type Calibration Display Limit relay Communication Moisture
Cable connector kit
IPD12222130
IPD12222230
IPD12223130
IPD12223230
IPD12322130
IPD12322230
IPD12323130
IPD12323230
Mineral
Mineral
Mineral
Mineral
Mineral
Mineral
Mineral
Mineral
MTD
MTD
MTD
MTD
MTD
MTD
MTD
MTD
LED
LED
LED
LED
Digital
Digital
Digital
Digital
YES
YES
YES
YES
YES
YES
YES
YES
RS232/4-20mA
RS232/4-20mA
RS232/0-5V
RS232/0-5V
RS232/4-20mA
RS232/4-20mA
RS232/0-5V
RS232/0-5V
NO
YES
NO
YES
NO
YES
NO
YES
M12,8pinplugconnector
M12,8pinplugconnector
M12,8pinplugconnector
M12,8pinplugconnector
M12,8pinplugconnector
M12,8pinplugconnector
M12,8pinplugconnector
M12,8pinplugconnector
Standard Products Table
Key Fluid type
Calibration Display Communication
Cable connector kit
MoistureLimit relay
ProductConfigurator
IPD 1
2
3
Mineral
Phosphate ester
Aviation fuel
(4 channel)
2 MTD
LED
Digital
2 Yes
2 RS232 / 4-20mA
3
5
RS232 / 0-5V
RS232/CAN-bus
(J1939)
10
Yes
Deutsch12-pinDTSeriesconnector
M12, 8 pin plug connector
icountPD
Online Particle Detector
2
3
1
2
30
1metrehoselength
2metrehoselength
5 metre hose length
1
/4”BSPfitting
1
/8”BSPfitting
1
/8”BNPTfitting
Single point sampler
Flow control device
Flow control valve
12voltregulatedpowersupply
2 x 5 m e t r e M 1 2 - 8 p i n c a b l e k i t * 
DeutschConnectorKit
RS232ToUSBcablekit
M12-8pintoRS232engineerstool
Description
Part number
Mineral fluids
ACC6NE003
ACC6NN003
ACC6NN005
ACC6NN007
ACC6NN009
ACC6NN011
SPS2021
S840074
ACC6NN019
ACC6NN013
ContactParkerACC6NN014
ACC6NN016
ACC6NN017
ACC6NN018
Aggressive fluids
ACC6NN002
ACC6NN004
ACC6NN006
ACC6NN008
ACC6NN010
ACC6NN012
SPS2061
ContactParker
ContactParker
*M12Cablekitconsistsoftwo5metrecablestoenablealloutputoptions
(CommunicationscableandRelay/PowerSupplycable)
**Notethattheaggressivefluidhosesareprovidedasasinglehose,notinpairs.
Note:FordetailsontheicountPDZ2ATEXapprovedparticledetectorseepage457.
Accessories
Part number Supersedes Size Flow range l/min
STI0144100
STI1144100
STI2144100
STI0148100
STI1148100
STI2148100
STS5117210
STS5217210
0
1
2
0
1
2
1
2
6-25
20-100
80-380
6-25
20-100
80-380
20-100
80-380
Fluid type
Mineral
Mineral
Mineral
Aggressive
Aggressive
Aggressive
Mineral
Mineral
3
/8
3
/4
1
1
/4
3
/8
3
/4
1
1
/4
3
/4
1
1
/4
STI.0144.100
STI.1144.100
STI.2144.100
STI.0148.100
STI.1148.100
STI.2148.100
STS.5117.210
STS.5217.210
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Port threads
Reverse Flow
capability
Note-AviationFueloptioncanalsobeusedforDieselfluids
Note-RS485option-communicationupto5000Meters-ContactParker
Note-Wirelesscommunication(GPRS-LAN-WiFi-Sat)-ContactParker