Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
8-111
2-Way Prop. Throttle Valve with Shut-Off Valve
Series TEA
TEA UK.INDD CM 09.11.15
General
Design 2-way proportional throttle valve, slip-in cartridge according to ISO 7368
Nominal size
NG25 NG32 NG40 NG50 NG63 NG80 NG100
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTF
D
value [years] 75
Weight [kg] 7.5 9 13 22 38 62 85
Extracting tools See accessories
Hydraulics
Max. operating pressure [bar] Ports A, B and X up to 350, port Y max. 10
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted
recommended
[cSt]/[mm
2
/s]
[cSt]/[mm
2
/s]
20...400
30...80
Filtration ISO 4406 (1999); 18/16/13
Nominal flow ∆p = 10 bar [l/min] 500 950 1400 2300 4000 6000 9500
Pilot pressure, min. [bar] > 25 % of system pressure
Pilot oil supply Depending on flow direction A or B using X or external X
Pilot oil at p = 100 bar [l/min] Port X → Y <1.5
Opening point At 30 % of nominal current
Manufacturing tolerance [%] ±5 of Qnom
Static/dynamic
Response time at px = 50 bar [ms] 25 30 35 45 55 65 80
Hysteresis [%] < 3
Repeatability [%] < 1
Electrical (proportional solenoid)
Duty ratio 100 % ED
Protection class IP65 according to EN 60529 (with correctly mounted plug-in connector)
Solenoid Code L X
at size 16-50 63-100 16-50 63-100
Solenoid voltage [V] 6 16
Nominal current (100 % ED) [A] 2.6 1.05
Nominal resistance [Ohm] 2.2 2.5 11.3 14
Power amplifier, recommended PCD 00A-400, Connector as per EN 175301-803
Pilot valve 4/2 flow control valve
Type D1VW (NG25-NG50), Type D3DW (NG63-NG100)
Ordering Code / Technical Data
Ordering code
Technical data
Nominal
size
2-way Prop.
throttle
valve with
shut-off
function
Cartridge
valve
ISO 7368
Flow
code
Spool
form
Plug
socket
without
plug
Flow
direction
Solenoid
voltage
Design
Seals
Pilot oil
guide
Design
series
(not required
for ordering)
Code Nominal size
025 NG25
032 NG32
040 NG40
050 NG50
063 NG63
080 NG80
100 NG100
Code Seal
N NBR
V FPM
Code Flow direction
A A to B
B B to A
Prop.
solenoid
voltage
Code
Proportional
solenoid voltage
L 6 VDC
X 16 VDC
E
TEA
W90W 2
Code Solenoid
J 24 V= / 1.25 A
U
1)
98 V= / 0.31 A
G
1)
205 V= / 0.15 A
1)