Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
8-110
TEA UK.INDD CM 09.11.15
2-Way Prop. Throttle Valve with Shut-Off Valve
Series TEACharacteristics
Example accumulator system in a die casting machine
Y
A
B
X
Accumulator discharge valves series TEA are preferably
used in hydraulic systems where high flow rates are
discharged from hydraulic accumulators over a short
operating period (in the range of milliseconds). Typical ap-
plications are injection molding and die casting machines
as well as hydraulic presses.
Basically the function of an accumulator discharge valve
corresponds to the function of a TDA throttle valve. In ad-
dition a directional valve is integrated in the pilot circuit
to meet the relevant safety regulations.
The directional valve provides the safety function. When
the solenoid is deenergized and the spring is in end posi-
tion, pilot pressure from X presses the control piston into
lower end position and the main poppet is closed. As a
result the flow from B to A or from the reservoir system
to the machine is blocked.
Characteristic curve
Characteristic curve measured with HLP46 at 50 °C.
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
8-111
2-Way Prop. Throttle Valve with Shut-Off Valve
Series TEA
TEA UK.INDD CM 09.11.15
General
Design 2-way proportional throttle valve, slip-in cartridge according to ISO 7368
Nominal size
NG25 NG32 NG40 NG50 NG63 NG80 NG100
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTF
D
value [years] 75
Weight [kg] 7.5 9 13 22 38 62 85
Extracting tools See accessories
Hydraulics
Max. operating pressure [bar] Ports A, B and X up to 350, port Y max. 10
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Viscosity, permitted
recommended
[cSt]/[mm
2
/s]
[cSt]/[mm
2
/s]
20...400
30...80
Filtration ISO 4406 (1999); 18/16/13
Nominal flow p = 10 bar [l/min] 500 950 1400 2300 4000 6000 9500
Pilot pressure, min. [bar] > 25 % of system pressure
Pilot oil supply Depending on flow direction A or B using X or external X
Pilot oil at p = 100 bar [l/min] Port X Y <1.5
Opening point At 30 % of nominal current
Manufacturing tolerance [%] ±5 of Qnom
Static/dynamic
Response time at px = 50 bar [ms] 25 30 35 45 55 65 80
Hysteresis [%] < 3
Repeatability [%] < 1
Electrical (proportional solenoid)
Duty ratio 100 % ED
Protection class IP65 according to EN 60529 (with correctly mounted plug-in connector)
Solenoid Code L X
at size 16-50 63-100 16-50 63-100
Solenoid voltage [V] 6 16
Nominal current (100 % ED) [A] 2.6 1.05
Nominal resistance [Ohm] 2.2 2.5 11.3 14
Power amplifier, recommended PCD 00A-400, Connector as per EN 175301-803
Pilot valve 4/2 flow control valve
Type D1VW (NG25-NG50), Type D3DW (NG63-NG100)
Ordering Code / Technical Data
Ordering code
Technical data
Nominal
size
2-way Prop.
throttle
valve with
shut-off
function
Cartridge
valve
ISO 7368
Flow
code
Spool
form
Plug
socket
without
plug
Flow
direction
Solenoid
voltage
Design
Seals
Pilot oil
guide
Design
series
(not required
for ordering)
Code Nominal size
025 NG25
032 NG32
040 NG40
050 NG50
063 NG63
080 NG80
100 NG100
Code Seal
N NBR
V FPM
Code Flow direction
A A to B
B B to A
Prop.
solenoid
voltage
Code
Proportional
solenoid voltage
L 6 VDC
X 16 VDC
E
TEA
W90W 2
Code Solenoid
J 24 V= / 1.25 A
U
1)
98 V= / 0.31 A
G
1)
205 V= / 0.15 A
1)
To be used in combination with rectifier plugs at 120 VAC / 230 VAC power supply.
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
8-112
TEA UK.INDD CM 09.11.15
2-Way Prop. Throttle Valve with Shut-Off Valve
Series TEADimensions
TEA NG25...50
TEA NG63...100
Size 25 32 40 50 63 80 100
H 239 250 260 270 312 337 352
b1 85 102 125 140 180 Ø 250 Ø 300
d1
H7
45 60 75 90 120 145 180
d2
H7
34 45 55 68 90 110 135
t2
+0.1
72 85 105 122 155 205 245
B2
total
98 106 118 125 158 193 218
B3
total
208 205 216 224 255 290 315
NG Kit
ISO 4762-12.9
NBR FPM
25 BK391 4x M12x50 108 Nm SK-TEAN10E25 SK-TEAN10E25V
32 BK415 4x M16x55 264 Nm SK-TEAN10E32 SK-TEAN10E32V
40 BK416 4x M20x70 517 Nm SK-TEAN10E40 SK-TEAN10E40V
50 BK417 4x M20x75 517 Nm SK-TEAN10E50 SK-TEAN10E50V
63 BK418 4x M30x100 1775 Nm SK-TEAN10E63 SK-TEAN10E63V
80 BK419 8x M24x120 890 Nm SK-TEAN10E80 SK-TEAN10E80V
100 BK420 8x M30x140 1775 Nm SK-TEAN10E100 SK-TEAN10E100V