10
10-8
Pilot Operated Pressure Reducing Valve
Series R4R
R4R UK.indd CM 03.03.16
Catalogue HY11-3500/UK
Parker Hanniļ¬n Corporation
Hydraulics Group
Characteristics
Pilot operated pressure reducing valves for in-line mount-
ing series R4R have a similar design to the subplate
mounted R4R series. For single functions ā€“ where no
manifold blocks are used ā€“ the valves can be directly
placed in the pipework.
The valves are available with 2 ports (L-body) or with 3
ports (T-body).
Features
ā€¢ī€€ Pilot operated with manual adjustment
ā€¢ī€€ Normally closed to avoid undesired motion
ā€¢ī€€ 2 interfaces
- L-body (R4R06-GĀ¾", R4R10-G1Ā¼")
- T-body (R4R03-GĀ½", R4R06-G1")
ā€¢ī€€ 3 pressure stages
ā€¢ī€€ 3 adjustment modes
- Hand knob
- Acorn nut with lead seal
- Cylinder lock
ā€¢ī€€ With optional vent function
R4R10 L-body
R4R06 L-body
R4R
5
2
B
10
10-9
Pilot Operated Pressure Reducing Valve
Series R4R
R4R UK.indd CM 03.03.16
Catalogue HY11-3500/UK
Parker Hanniļ¬n Corporation
Hydraulics Group
Drain line
ext. from
pilot head
(Y1)
Ordering Code
Code Seal
1 NBR
5 FPM
Code Nominal size
03 NG10 (GĀ½")
06
NG25
(G1" - T-body,
GĀ¾" - L-body)
10 NG32 (G1Ā¼")
Max.
pressure
350 bar
Pressure
stages
Pressure
reducing
valve
Design
series
Seal OptionsNominal
size
Body
Code Body
6
R4R03 T-body
R4R06 T-body
D
R4R06 L-body
R4R10 L-body
Code Pressure stages
1 up to 105 bar
3 up to 210 bar
5 up to 350 bar
Adjust-
ment
Switching
type
Solenoid
voltage
Code Adjustment
1 Hand knob
3
Acorn nut
with lead seal
4 Cylinder lock
Code Solenoid voltage
omit
Standard w/o
vent function
G0R 12 V=
G0Q 24 V=
GAR
1)
98 V=
GAG
1)
205 V=
W30
110 V / 50 Hz
120 V / 60 Hz
W31
230 V / 50 Hz
240 V / 60 Hz
1)
To be used in combination with rectiļ¬er plugs at 120 VAC / 230 VAC power supply.
Code Switching type
omit Standard w/o vent function
09
Solenoid not activated,
pressure reducer non-active
11
Solenoid activated
pressure reducer non-active
10
10-10
Pilot Operated Pressure Reducing Valve
Series R4R
R4R UK.indd CM 03.03.16
Catalogue HY11-3500/UK
Parker Hanniļ¬n Corporation
Hydraulics Group
General
Design
T-body L-body
Size
03 (Ā½") 06 (Ā¾") 06 (1") 10 (1Ā¼")
Mounting Threaded body
Mounting position unrestricted
Ambient temperature [Ā°C] -20...+60
MTTF
D
value [years] 75
Weight [kg] 4.9 5.0 7.3 8.3
Hydraulic
Max. operating pressure [bar] Ports A and X up to 350; Ports B and Y depressurized
Pressure stages [bar] 105, 210, 350
Nominal ļ¬‚ow [l/min] 60 200 200 450
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [Ā°C] -20...+70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm
2
/s] 20...400
Viscosity recommended [cSt] / [mm
2
/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Electrical (solenoid)
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 Ā°C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code
G0R G0Q GAR GAG W30 W31
12 V = 24 V = 98 V = 205 V =
110 at 50 Hz
120 at 60 Hz
230 at 50 Hz
240 at 60 Hz
Ā±10 Ā±10 Ā±10 Ā±10 Ā±5 Ā±5
2.72 1.29 0.33 0.13 0.6 / 0.55 0.3 / 0.27
2.72 1.29 0.33 0.13 2.5 / 2.4 1.25 / 1.2
32.7 31 31.9 28.2 70 / 70 VA 70 / 70 VA
32.7 31 31.9 28.2 280 / 290 VA 280 / 290 VA
Supply voltage
[V]
[V]
Tolerance supply voltage [%]
Current consumption hold [A]
in rush [A]
Power consumption hold [W]
in rush [W]
Solenoid connection Connector as per EN175301-803, solenoid identiļ¬cation as per ISO 9461
Wiring min. [mm
2
] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
Technical Data
R4R
R4R with vent function
General
Design
T-body L-body
Size
03 (Ā½") 06 (1") 06 (Ā¾") 10 (1Ā¼")
Mounting Threaded body
Mounting position unrestricted
Ambient temperature [Ā°C] -20...+60
MTTF
D
value [years] 75
Weight [kg] 3.2 3.3 5.6 6.6
Hydraulic
Max. operating pressure [bar] Ports A, B and X: 350; Port Y depressurized
Pressure stages [bar] 105, 210, 350
Nominal ļ¬‚ow [l/min] 60 200 200 450
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [Ā°C] -20...+70 (NBR: -25...+70)
Viscosity permitted [cSt]/[mm
2
/s] 20...400
Viscosity recommended [cSt]/[mm
2
/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
10
10-11
Pilot Operated Pressure Reducing Valve
Series R4R
R4R UK.indd CM 03.03.16
Catalogue HY11-3500/UK
Parker Hanniļ¬n Corporation
Hydraulics Group
Characteristic Curves
Reduced pressure pA versus ļ¬‚ow Q
R4R03
1)
Reduced pressure pA versus ļ¬‚ow Q
R4R06
1)
Reduced pressure pA versus ļ¬‚ow Q
R4R10
1)
Minimum pressure curve
1)
Measured at 350 bar primary pressure pB.
Minimum pressure curve
Minimum pressure curve
Pressure p [bar]
5
0
10
15
20
25
30
10050 150
Flow Q [l/min]
5
0
15
10
25
20
30
25015050 100 200 300 350
Flow Q [l/min]
Pressure p [bar]
Pressure p [bar]
10
0
20
30
40
50
60
100 200 300 400 500
Flow Q [l/min]
70
80
All characteristic curves measured with HLP46 at 50 Ā°C.
10
10-12
Pilot Operated Pressure Reducing Valve
Series R4R
R4R UK.indd CM 03.03.16
Catalogue HY11-3500/UK
Parker Hanniļ¬n Corporation
Hydraulics Group
Dimensions
NG Body B1 B2 B3 B4 H1 H2 H3 H4 H5 H6 L1 L2 L3
03 T-body 85 ā€“ ā€“ ā€“ 27.5 59.5 97.5 ā€“ ā€“ ā€“ 53 92 ā€“
06 T-body 136 ā€“ ā€“ ā€“ 38 93 131 ā€“ ā€“ ā€“ 66.5 117.5 ā€“
06 L-body ā€“ 81 76 43 ā€“ ā€“ ā€“ 51 81 119 ā€“ ā€“ 49
10 L-body ā€“ 120.7 85.8 77.8 ā€“ ā€“ ā€“ 50.8 96 134 ā€“ ā€“ 49.8
Ports Function
Port size
R4V03 T-body R4V06 L-body R4V06 T-body R4V10 L-body
B pressure (inlet) GĀ½ " GĀ¾ " G1 " G1Ā¼ "
A pressure (outlet) GĀ½ " GĀ¾ " G1 " G1Ā¼ "
X1 external remote control or vent connection GĀ¼ " GĀ¼ " GĀ¼ " GĀ¼ "
Y1 external drain GĀ¼ " GĀ¼ " GĀ¼ " GĀ¼ "
T-body L-body
Seal kits
NG NBR FPM
03 S26-58507-0 S26-58507-5
06 S26-58475-0 S26-58475-5
10 S26-58508-0 S26-58508-5
10
10-13
Pilot Operated Pressure Reducing Valve
Series R4R
R4R UK.indd CM 03.03.16
Catalogue HY11-3500/UK
Parker Hanniļ¬n Corporation
Hydraulics Group
51.8
70
15
Y1X1
Y1
143 max.
60.3
85
47
Vent valve
Main valve
Pilot valve
X1
38.6
R4R with vent function
Dimensions
Code External drain
11
B
A
X
Y1
Z
XY
09
B
A
X
Y1
Z
XY
Seal kits
NBR FPM
DC solenoid
S56-40609-0 S56-40609-5
AC solenoid
S26-35237-0 S26-35237-5