Installation and start-up for F1
Drain line
Fixed displacement pumps don’t
need an external drain line as they
are internally drained.
When the pump is mounted in a
Engine-PTO we recommend a drain
line from the bypass valve directly to
oil tank.
Filtration
Filtration should follow ISO standard
4406, code 20/18/13.
To obtain the longest life of fixed dis-
placement pumps, we recommend
an oil cleanliness
of 10 µm (absolute).
Start-up
Make sure the entire hydraulic sys-
tem is clean before filling it with
arecommendedhydraulicuid.
In particular, make sure the pump is
filled (to at least 50%) as the internal
leakage does not provide sufficient
lubrication at start-up.
Fluids
The fixed displacement pumps data
shown in the specifications for each
pump in chapter 1 and 2 are valid
when operating on high quality, min-
eral based hydraulic oil.
Type HLP (according to DIN 51524)
hydraulic oil is suitable as well as
biologicallydegradeableuidslike
natural and synthetic esters and
polyalfaolefins.
Theutilisedhydraulicuidshall
meet one of the following Swedish
standards:
- SS 15 54 34
- SMR Hydraulic Oil Standard 1996-2.
Contact Parker Hannifin for further
information.
NOTE: - ATF (automatic transmis-
sionuid)andAPItype
CD engine oils may also
be useable.
- Seals are made of nitrile
rubber; make sure the
utiliseduidiscompatible
with this material.
Fluid temperature
Main circuit: Max 75 °C 167 °F.
NOTE: - The suction port should
always be above the
pressure port when the
pump is installed above
the reservoir oil level.
- During operation, the
pump must be filled with
oil to at least 50%.
Direction of rotation
The pictures above show direction of
owvs.shaftrotation.
The direction of rotation can be
changed (i. e. from right hand to left
hand) by turning the end cap.
Remove the four cap screws and turn
the end cap about half a turn while
making sure it stays in contact with
the barrel housing.
Re-fit the cap screws and torque to
59-74 lbf ft (80-100 Nm).
Installation
Make sure max torque and bending
moment (due to the weight of the
pump) of the utilised PTO are not
exceeded. (The approx. center of
gravity of the various pump sizes are
shown in the installation drawings).
NOTE: In order to obtain the longest
bearing life, the pump should
be installed according to
the
information shown on
page 20 "Pump bearing life".
Fluid viscosity
Recommended viscosity:
20 to 30 mm
2
/s (cSt).
Operating viscosity limits:
- Min 10 mm
2
/s; max 400 mm
2
/s.
- At start-up, max 4000 mm
2
/s.
Right hand (R.H.;
clockwise) rotating pump.
Left hand (L.H.; counter
clockwise) rotating pump.
Before start-up, the housing must
be filled with hydraulic fluid.
F2_inlet_positions.eps
Leif A./000302
Truck Hydraulics
F1 SAE
Installation and start up