PCL4
Remote Control
Hydraulic Proportional Remote Control Valve
Remote Controls – Hydraulic
PCL4
2
Catalogue HY17-8357/UK
Parker Hannifin
Mobile Controls Division Europe
Borås, Sweden
Catalogue layout
This catalogue has been designed to give an overview of the
PCL4 series of valves and to make it easy for you to study and
choose from the different valve functions available, so that we
may customize your valve in accordance with your wishes.
General information and technical data is given first, followed
by descriptions of the various options that can be specified and,
finally, by dimensional drawings for the respective valves.
Each function is given as a subheading, e.g. Levers, followed
by a brief description. This is followed by a series of alphanu-
meric codes, e.g. H1, H2, E4, together with a brief description of
what each code represents.
How to order your valve
The next step is to complete our so-called “Customer Specifica-
tion Form”, which enables detailed specification of the optional
functions and port-specific control-pressure characteristics you
wish to be incorporated into your valve. However, if you require
only a simple, basic valve, in which all control-pressure ports
have the same configuration, you can specify your valve by
determining an ordering code in accordance with the information
given on page 5. It is simply a matter of entering the codes for
the desired options into the boxes in the ordering code, as shown
in the example.
For assistance in configuring your valve, completing the
Customer Specification Form or determining the ordering code,
please do not hesitate to contact your nearest Parker representa-
tive.
The information in your Customer Specification Form will
be entered into our computerized valve specification program,
which generates a unique ID number that will be stamped into
the data plate on your valve. (If you order your valve by means of
an ordering code, the code will be stamped into the data plate on
your valve.) Your valve specifications will then be stored on our
database to facilitate accurate identification of the product in the
event of re-ordering or service-related question s.
Conversion factors
1 kg = 2.2046 lb
1 N = 0.22481 lbf
1 bar = 14.504 psi
1 l = 0.21997 UK gallon
1 l = 0.26417 US gallon
1 cm
3
= 0.061024 in
3
1 m = 3.2808 feet
1 mm = 0.03937 in
9/5 °C + 32 = °F
Catalogue Information
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS
CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide
product or system options for further investigation by users having technical expertise.
The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components
and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The
user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning
the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized
distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or
specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and
sufficient for all applications and reasonably foreseeable uses of the components or systems.
Offer of Sale
Please contact your Parker representation for a detailed ”Offer of Sale”.
WARNING – USER RESPONSIBILITY
Early consultation with Parker saves
time and money
Our experienced applications engineers have in-depth knowl-
edge of different hydraulic systems and the ways in which they
work. They are at your disposal to offer expert advice on the
desired combination of functions, control characteristics and
economic demands.
By consulting Parker early in the project planning stage, you
are assured of a comprehensive hydraulic system that gives your
machine the best possible operating and control performance.
Subject to alteration without prior notice. The diagrams in the
catalogue show typical curves only. While the contents of the
catalogue are updated continuously, the validity of the informa-
tion given should always be confirmed. Technical information in
the catalogue is applicable at an oil viscosity of 30 mm
2
/s and
temperature of 50 °C. For more detailed information, please
contact Parker.
Remote Controls – Hydraulic
PCL4
3
Catalogue HY17-8357/UK
Parker Hannifin
Mobile Controls Division Europe
Borås, Sweden
Index
Contents Page
Catalogue Information ....................................................................................................2
General Information ........................................................................................................4
Ordering Code ................................................................................................................5
Technical Data ................................................................................................................6
Lever forces ....................................................................................................................7
Electrical data ................................................................................................................7
Connections ....................................................................................................................7
Weight ............................................................................................................................7
Valve type .......................................................................................................................8
Control pressure ports ....................................................................................................8
Connections ....................................................................................................................8
Location of connections ..................................................................................................8
Control pressure .............................................................................................................8
Mounting plate ................................................................................................................9
Extra centring springs .....................................................................................................9
Lever E1 .........................................................................................................................9
Levers E2, E3, E4 ...........................................................................................................9
Activating devices .........................................................................................................10
Lever N2T .....................................................................................................................10
Lever N4T .....................................................................................................................10
Lever detents for PCL402 .............................................................................................11
Friction brake for PCL402 .............................................................................................11
Shuttle valve for signal on activation of valve ...............................................................11
PCL401 levers ..............................................................................................................12
Dimensional Drawings ............................................................................................ 12-17
Remote Controls – Hydraulic
PCL4
4
Catalogue HY17-8357/UK
Parker Hannifin
Mobile Controls Division Europe
Borås, Sweden
The PCL4 is a stackable hydraulic
control-pressure valve intended for the
proportional, hydraulic remote control of
directional valves, pumps with variable
displacement, positioning cylinders, etc. It
can be obtained with a co-ordinate lever
(joystick), linear lever or foot pedal as the
activating device.
Freedom in machine design
Good machine design is heavily
dependent on the availability of versa-
tile components and systems that can
be combined in different ways to give
optimum operating and control character-
istics. Parker control systems give you the
freedom to design your machines the way
you want them, since they enable compo-
nents such as directional valves and other
control devices to be located ideally on
the machine. This also gives advantages
in production, since it greatly facilitates
the building of machine sub-assemblies
at different sites prior to collation for final
assembly.
Parker supplies a wide range of
pneumatic, hydraulic and electric control
devices that enable optimum ergonomic
design of the machine-control station.
(Please see separate brochures for
information on our hydraulic and electric
remote-control systems.)
Safety
The robust and simple construction of the
PCL4 remote control valve makes it very
reliable and greatly facilitates training and
servicing. This, together with consistently
predictable control properties, gives a high
level of operational safety for many years.
Design
The valve is made up of sections, each
of which contains two 3-way pressure
reducing valves (one per signal port). Up
to 6 sections can be stacked into one
and the same valve to give a total of 12
signal ports. Valves with four signal ports
can be equipped with a coordinate lever
(joystick). The cast-iron valve housing and
reducer-valve spools of hardened, preci-
sion-ground steel ensure a long service
life with minimal internal leakage. Special
low-friction seals give effective protection
against external leakage.
The PCL4 is designed to give minimal
hysteresis and very good long-term control
characteristics.
Levers are of corrosion-resistant steel
and can be fitted with plastic handles,
balls or window knobs. Pedals can be of
corrosion-resistant, pressed steel plate,
aluminium or rubber-coated steel.
Essential characteristics
Small dimensions enable simple,
compact installation.
Robust, simple design gives great
reliability and easy servicing.
Low, well-adapted lever forces and
short lever strokes give good operating
comfort.
Lever forces can be specified per
control-pressure port to give function-
specific actuational resistance.
Low hysteresis gives consistent
machine -function response to valve
actuation.
Good metering properties enable
gentle, proportional control.
Very wide range of control-pressure
characteristics enables control of
machine functions to be application-
optimized.
Wide range of control devices and
accessories gives great flexibility in
system design.
Valve can be installed in arm rests of
operator’s seat and fitted with site-
suited lever to give very ergonomic
control station.
Quality materials and great precision in
manufacturing, assembly and testing
assure a quality product with low
internal leakage and long service life.
Total compatibility with Parker direc-
tional valves gives predictable and
harmonious system characteristics.
General Information
Remote Controls – Hydraulic
PCL4
5
Catalogue HY17-8357/UK
Parker Hannifin
Mobile Controls Division Europe
Borås, Sweden
See pages 8 - 11 for more information about the different options available.
How to order your valve
The best way to order your valve is to fill in one of our “Customer
Specification Forms”, in which you can specify all the optional
functions you wish to be incorporated into your valve. However, if
you need only a simple, basic valve, in which all control-pressure
ports have the same configuration, you may use an ordering
code similar to the one shown above. Simply select the desired
options from the tables above and enter the appropriate codes
into the boxes in the ordering code above.
Ordering Code
Number of control-
pressure ports
2
4
6
8
10
12
Code Connection
S Pump and tank
connections on
side of valve
B Pump and tank
connections on
underside of valve
Code Thread connections
G G1/4
U 9/16-18 UNF-2B
M M14x1.5
Code Characteristic
No Breakaway Final Broken Overtr.
pressure pressure stroke
1 1.0 11.1
2 2.0 5.4
3 2.0 10.5
4 5.0 15.6
5 5.0 17.7
6 5.0 20.9
7 5.0 24.9
8 5.5 15.6
9 5.6 21.5
10 6.0 27.2
11 4.0 22.6 yes
12 5.0 27.0 yes
13 6.0 27.5 yes
14 5.0 16.5 yes yes
Code Mounting plate
M1 Mounting plate for PCL401
M2 Mounting plate for PCL402 with
four control-pressure ports
M3 Mounting plate for PCL402
M4 Mounting plate for PCL402 with
two control-pressure ports
M5 Mounting plate for PCL402
M6 Mounting plate for PCL402
M9G Mounting plate for PCL402 for
Gresen replacement
M10C Mounting plate for PCL402 for
Commercial replacement
A102 Mounting plate for PCL401,
rectangular bellows (for PCL401
with N-type levers only)
Code Valve type
01 For coordinate
lever
02 For linear lever(s)
or pedal
Code Lever unit
X Without lever and boot
H1 Coordinate lever
H3 Straight linear lever
HF Bent linear lever for in-
creased spacing in case
of several levers
E1 Linear or coordinate lever
2-position thumb switch
E2 Linear or coordinate lever
3-position toggle switch
E3 Linear or coordinate lever
3-position toggle switch
1 detent position
E4 Linear or coordinate lever
3-position toggle switch
2 detent positions
N0 Coordinate lever without
thumb switch
N2 Coordinate lever with
2 thumb switches
N2T Coordinate lever with
3 thumb switches
N4 Coordinate lever with
4 thumb switches
N4T Coordinate lever with
5 thumb switches
F Pedal, pressed steel
A36 Pedal, cast aluminium
A95 Pedal, rubber coated steel
plate
Code Lever type
/ Without option, when
X as lever unit
S Straight*
L Bent to the left*
R Bent to the right*
B Ball**
W Window**
* Type N levers only
** Type H levers only
PCL4
Valve
type
Thread
connection
Pump and
tank connec-
tion
Mounting
plate
Lever unit Lever
type
Charac-
teristics
Control
pressure
ports
Remote Controls – Hydraulic
PCL4
6
Catalogue HY17-8357/UK
Parker Hannifin
Mobile Controls Division Europe
Borås, Sweden
General
The data given is applicable at an oil temperature of 50 °C
(122 °F) and viscosity of 30 mm
2
/s (cSt) using mineral base oil
according to DIN 51524.
Pressures
Supply pressure (pump pressure) max. 100 bar (1450 psi)
Recommended supply pressure 15 bar (218 psi)
higher than max.
control pressure
Control pressure max. 75 bar 1090 psi)
Breakaway pressure min. 1 bar, (14,5 psi)
max. 16 bar (232 psi)
Return-line pressure max. 3 bar (44 psi)
Flow rate
Control flow max. 15 l/min (4 USgpm)
Hysteresis
Hysteresis max. 0.5 bar (7,3 psi)
Hydraulic fluids
Best performance is obtained using mineral-base oil of high
quality and cleanness in the hydraulic system.
HLP hydraulic fluids (DIN 51524), automatic-gearbox oil type
A and API CD engine oils can be used.
Viscosity range 10-380 mm
2
/s (cSt)
Performance efficency will be reduced if outside the ideal values.
These extreme conditions must be evaluated by the user to
establish suitability of the products performance.
Filtration
Filtration should be arranged so that the Target Contamination
Class 18/16/13 according to ISO 4406 is not exceeded.
Warning
If the filtration demands are not met, the valve poppets
can jam in the open position, with the result that the valve
remains actuated. It is not possible to force back jammed
poppets mechanically.
Technical information in this catalogue is applicable at an
oil viscosity of 30 mm
2
/s and temperature of 50 °C using
nitrile rubber seals.
Temperature
Min. ambient temperature –40 °C (-40 °F)
Max. ambient temperature +60 °C (140 °F)
Min. oil temperature –20 °C (-4 °F)
Max. oil temperature +70 °C (166 °F)
Temperature change max. 100 °C/s.
max. 212 °F/s
Product operating limits are broadly within the above range,
but satisfactory operation within the specification may not be
accomplished. Leakage and response will be affected when used
at temperature extremes and it is up to the user to determine
acceptability at these levels.
Leakage
From pump connection to tank
connection with the spool in max. 20 cm
3
/min
neutral position and a supply (1.22 in
3
)per
pressure of 40 bar (580 psi) control-pressure port
Technical Data
Lever unit
(activating
device)
Bellows
Lever detent
MD2
Signal ports
Regulator
Spool
Pump
connection
Tank
connection
Mounting plate
Extra
centring
spring
Remote Controls – Hydraulic
PCL4
7
Catalogue HY17-8357/UK
Parker Hannifin
Mobile Controls Division Europe
Borås, Sweden
Lever forces
All lever forces stated are applicable at a control pressure of 15
bar (valve not fitted with an extra centring spring). Pedal forces are
applicable when the C2 centring spring is used
(see page 9).
Normal force for linear lever, fully actuated 1.2 Nm
Normal force for coordinate lever (joystick)
one function fully actuated 1.8 Nm
two functions fully actuated 2.4 Nm
Normal force for pedal, fully actuated 5.7 Nm
Electrical data
(applies to switch in E- and N-type levers)
The data given below is what is needed to obtain the maximum
service life. The values can be exceeded with retained function,
but will result in a reduction in service life.
In the event of inductive loading, a protective diode must be fitted.
Breaking capacity
DC, resistive loading 2A/24V
DC or AC, inductive loading 1A/24V
Connections
Three different types of connection thread are available:
G1/4 for flat seal (type Tredo) according to ISO 228/1 (G version)
9/16-18 UNF-2B (for O-ring) according to SAE J1926/1 (U version)
M14 x 1.5 (metric ISO thread) for flat seal (M version)
Weight
The weight of the unit varies with its configuration. A few
examples are given below.
Valve with linear lever approx. 1.6 kg/section
Valve with coordinate lever approx. 3.2 kg
Valve with pedal (F) approx. 3.0 kg
Circuit diagram showing two-section PCL4 with two linear levers
controlling one hydraulic directional valve containing two spool
sections.
Circuit diagram showing two-section PCL4 with one coordinate
lever (joystick) controlling one hydraulic directional valve
containing two spool sections.
Technical Information
Remote Controls – Hydraulic
PCL4
8
Catalogue HY17-8357/UK
Parker Hannifin
Mobile Controls Division Europe
Borås, Sweden
Valve type
PCL401 Valve with coordinate lever (joystick)
PCL402 Valve with linear lever(s) or pedal
Control pressure ports
2-12 4 in PCL401
2, 4, 6, 8, 10 or 12 in PCL402
Connections
G Connections with G1/4 thread
U Connections with 9/16-18 UNF-2B thread
M Connections with M14 x 1.5 thread
Location of connections
All control-pressure ports are located on the underside of the
valve. The pump and tank connections can be located on the
underside or side of the valve. See dimensional drawings.
S Pump and tank connections fitted on the side of the
valve.
B Pump and tank connections fitted on the underside of
the valve.
Control pressure
Control pressure characteristics can be obtained in an almost
infinite number of versions. They are classified into four different
groups.
Straight characteristic
Straight characteristic with overtravel stroke
Broken characteristic
Broken characteristic with overtravel stroke
With the straight characteristic, the control pressure changes
proportionally with the lever stroke. With the broken characteristic,
the control pressure changes proportionally with the lever stroke
up to a pre-determined breakpoint, after which the characteristic
continues to change proportionally, but with a steeper character-
istic. This is useful when there is a big difference between brea-
kout pressure and final pressure and a need to fine-regulate the
beginning of the stroke.
With the overtravel stroke, the control pressure becomes
equal to the supply pressure. This is recommended primarily for
directional valves that have a free flow gallery (CFO). The over-
travel stroke serves to ensure full actuation regardless of any
return-spring tolerances in the spool actuator of the directional
valve.
To calculate a suitable control-pressure characteristic, the
following information is needed:
Breakout pressure:
The pressure at which the valve just begins to open.
Selectable between 1 and 16 bar.
Final pressure:
Max. control pressure (fully actuated activating device)
or, in case of overtravel stroke, the pressure level
obtained on reaching the overtravel stroke. Selectable
between 5.5 and 75 bar.
Breakpoint:
The lever stroke and pressure at which the broken char-
acteristic changes characteristic.
Overtravel stroke:
The part of the activating-device stroke that constitutes
overtravel.
For assistance in calculating the most suitable control-pressure
characteristic, please contact your nearest Parker representative.
Every valve is customized. The following options are used to configure a valve.
Control pressure in bar
20 40 60 80 100
0
10
15
20
25
5
0
20 40 60 80 100
0
10
15
20
25
5
0
20 40 60 80 100
0
10
15
20
25
5
0
20 40 60 80 100
0
10
15
20
25
5
0
Lever stroke in %
Diagram shows an example of a straight characteristic.
Control pressure in bar
Lever stroke in %
Diagram shows an example of a straight characteristic with over-
travel stroke that gives full supply pressure.
Control pressure in bar
Lever stroke in %
Diagram shows an example of a broken characteristic.
Control pressure in bar
Lever stroke in %
Diagram shows an example of a broken characteristic with over-
travel stroke that gives full supply pressure.
Final pressure
Breakaway pressure
Breakpoint
Final pressure
Full supply pressure
Breakaway pressure
Breakaway pressure
Breakaway pressure
Breakpoint
Full supply pressure
Final pressure
Final pressure
Technical Information
Remote Controls – Hydraulic
PCL4
9
Catalogue HY17-8357/UK
Parker Hannifin
Mobile Controls Division Europe
Borås, Sweden
Mounting plate
A number of different mounting plates for fitting the valve to the
machine are available (see dimensional drawings).
M1 Mounting plate for PCL401
M2 Mounting plate for PCL402 with four control pressure
ports
M3 Mounting plate for PCL402
M3S Same as M3 but in Stainless steel
M4 Mounting plate for PCL402 with two control pressure
ports
M5 Mounting plate for PCL402
M6 Mounting plate for PCL402
M9G Mounting plate for PCL402 for Gresen replacement
M10C Mounting plate for PCL402 for Commercial replacement
A102 Mounting plate for PCL401, rectangular bellows
(for PCL401 with type N levers only)
Extra centring springs
Any control-pressure port can be fitted with an extra centring
spring, which serves primarily to ensure centralization of the
lever unit. (Heavier lever units need stronger centring springs.)
Also, by fitting different springs at different ports, a coordinate
lever (for instance) can be given different actuational resi stances
for different functions. A list of the different springs available
is given in the table below, together with their respective force
increases on the push rod. These force values should not be
confused with the inherent lever forces, since the various acti-
vating devices have different ratios.
F1 is the force transmission on the activating device when the
spool is in the neutral position.
F2 is the force transmission on a fully actuated activating device.
F1 F2
C7 5 N 8 N
C0 19 N 33 N
C1 25 N 45 N
C5 35 N 71 N
C2 49 N 71 N
C3 51 N 92 N
C4 65 N 169 N
C6 100 N 214 N
C8 130 N 243 N
Black cable
Grey cable
Red cable
Breaker symbol
Grey cable
Black cable
Red cable
Breaker symbol
Lever E1
Thumb switch
Levers E2, E3, E4
Thumb switch
(toggle type)
The detent position
on lever E3 results in
a connection between
the red and black
cables.
Extra centring spring
Technical Information
Remote Controls – Hydraulic
PCL4
10
Catalogue HY17-8357/UK
Parker Hannifin
Mobile Controls Division Europe
Borås, Sweden
Activating devices
Several different types of activating device are available:
Straight lever with ball
Straight lever with window knob for insertion of functional
symbol
Straight lever with thicker plastic handle
(can be equipped with different switches)
Ergonomic multi-function lever that can be equipped
with up to 5 thumb-switches
• Pedal
See also dimensional drawings.
H1 Coordinate lever (joystick) with ball or window knob
H3 Straight linear lever with ball or window knob
H3S Lever H3 in stainless steel
H4-H7 Bent linear lever with ball or window knob
E0 Linear or coordinate lever without thumb switch
E1 Linear or coordinate lever with 2-position thumb switch
E2 Linear or coordinate lever with 3-position, spring-
centred toggle switch
E3 Linear or coordinate lever with 3-position toggle switch
with detent at one end position
E4 Linear or coordinate lever with 3-position toggle switch
with detents at both end positions
N0 Coordinate lever without thumb switch
N2 Coordinate lever with 2 instantaneous switches
(Nos. 1 and 2)
N2T Coordinate lever with 3 instantaneous switches
(Nos. 1, 2 and 5)
N4 Coordinate lever with 4 instantaneous switches
(Nos. 1-4)
N4T Coordinate lever with 5 instantaneous switches
(Nos. 1-5)
F Pedal of pressed steel plate
A36 Pedal of cast aluminium
A95 Pedal of rubber coated steel
Lever N2T
right-hand
version
Push buttons
Lever N4T
left-hand version
1234
5
Breaker symbol (colours of output cables)
Push button
White Green Brown Pink Grey Green/
yellow
Right-hand version of lever, i.e. intended for mounting in right-
hand arm rest.
Left-hand version of lever, i.e. intended for mounting in left-hand
arm rest.
1
2
34
5
Technical Information
Remote Controls – Hydraulic
PCL4
11
Catalogue HY17-8357/UK
Parker Hannifin
Mobile Controls Division Europe
Borås, Sweden
Lever detents for PCL402
Linear levers can be equipped with a detent that locks the lever
in the fully actuated position (for one or both control-pressure
ports).
MD2 Mechanical end-position detent. Released by pulling
the lever out of its detented position. It can be used with
signal pressures of up to 30 bar inclusive.
See figure on page 6.
ED2 Electric end-position detent. A solenoid locks the lever
in its fully actuated position. By means of a force index,
a greater resistance to lever actuation is felt by the
operator just before the lever enters the detented posi-
tion, i.e. after approx. 75% of the lever stroke. The lever
is released from the detented position by breaking the
current to the solenoid. In emergencies, the lever can
be pulled out of the detented position manually. Since
sections equipped with the ED2 do not have protec-
tive bellows, it is important that they are installed in the
machine in such a way as to prevent the ingress of dirt
(which would impair the function of the valve).
At a signal pressure of 35 bar, the holding force is
min. 19 N.
Electrical data:
Solenoid voltage: 24 VDC max. 3.2 W 100% ED
ED2 - electric end-position detent.
S2 - friction brake with centre-position indication.
Friction brake for PCL402
S2 Friction brake with centre-position indication. Movement
is braked so that the lever remains in any position in
which it is put. The centre position is index-marked for
reliable positioning into neutral. Due to the size of fric-
tion brake, a 35 mm spacer block is fitted between the
sections in valves containing more than one section.
See dimensional drawing.
Index that gives
increased resist-
ance to lever
actuation just before
the solenoid locks
the lever into the
detented position.
Electric holding
solenoid
Index that indicates
when lever is in
neutral
Brake unit
Shuttle valve for signal on activation of valve
A42 PCL402 with 2 control-pressure ports, and with the
pump and tank connections on the underside of the
valve, can be equipped with a shuttle valve that emits a
signal as soon as the valve is activated.
AS B
Signal obtained in port S on activation of valve.
Technical Information
Remote Controls – Hydraulic
PCL4
12
Catalogue HY17-8357/UK
Parker Hannifin
Mobile Controls Division Europe
Borås, Sweden
a) Applies to max. actuation of one function
b) Applies to max. actuation of two functions
PCL401 levers
22
200 c)
Ø40 d)
18° a) 25° b)
18° a) 25° b)
70
(2.76)
(7.87)
(0.87)
(Ø1.57)
85
22
235
18˚ a)
25˚ b)
18˚ a)
25˚ b)
(3.75)
(9.25)
(0.87)
22
235
220
18˚ a)
25˚ b)
18˚ a)
25˚ b)
115
55
56
(9.25)
(8.66)
(0.87)
(4.53)
(2.20)
(2.17)
Lever N0 - N4T
Straight version
Lever N0 - N4T
Right-hand version and A102 mounting plate
Lever E0 - E4 Lever H1 with ball
c) 210 with window knob
d) Ø27 with window knob
(inch)
Dimensional Drawings
Remote Controls – Hydraulic
PCL4
13
Catalogue HY17-8357/UK
Parker Hannifin
Mobile Controls Division Europe
Borås, Sweden
40
15
15
10
7
66
95
15
15
40
54
108
54
108
(4.25)
(2.13)
(1.57)
(0.59)
(0.59)
(0.39)
(3.74)
(2.60)
(0.28)
(0.59)
(0.59)
(1.57)
(2.135)
(4.25)
PCL401 valve housing
Control-pressure port 1
Pump
connection
Ø125
Ø100
30
15
15
30
20
70
7
(0.28)
(0.59)
(0.79)
(1.18)
(4.25)
(2.76)
(0.59)
(1.18)
(Ø3.94)
(Ø4.92)
4
96
(3.78)
(0.16)
31 (1.22)
32 (1.26)
4 (0.16)
96 (3.78)
Control-pressure
port 2
Control-
pressure
port 3
Control-pressure
port 4
Mounting hole, min. Ø85 mm
(3.35 inch)
Mounting hole, min Ø90 mm (3.54inch)
Tank
connection
Tank
connection
Pump
connection
Mounting screws out of
sight (under bellows)
PCL401 with all connections in the underside of the valve and
with A102 mounting plate.
PCL401 with tank and pump connections on the side of the valve
and with M1 mounting plate.
(inch)
Dimensional Drawings
Remote Controls – Hydraulic
PCL4
14
Catalogue HY17-8357/UK
Parker Hannifin
Mobile Controls Division Europe
Borås, Sweden
Ø25 (0.98)
50 (1.97)
50 (1.97) 50 (1.97) 50 (1.97) 50 (1.97)
15 (0.59)
30 (1.18)
45 (1.77)
190 (7.48)
200
26
25°
25°
83
27
(7.87)
1.06)
(3.27)
(1.02)
PCL402 Levers with ball
Lever H4
mounting position 4
Lever H3 Lever H4
mounting position 2
Lever H5 Lever H6
70 (2.76)
PCL402 with S2 friction brake on two sections PCL402 with H3 lever and window knob
Spacer block
Sections with S2
Lever H5
(inch)
Dimensional Drawings
Remote Controls – Hydraulic
PCL4
15
Catalogue HY17-8357/UK
Parker Hannifin
Mobile Controls Division Europe
Borås, Sweden
53
11
1
28,5
24,5
4
17,5
35 7
41
30 41
28
86
125
(0.96)
(0.16)
(0.69)
(2.59)
(0.43)
(0.04)
(1.12)
(1.38)
(Ø0.28)
(3.39)
(1.10)
(4.92)
(1.61)
(1.61)
(1.18)
80 (3.15)
63 (2.48)
40 (1.57)
20
L
4* (0.16)
31
32
96 (3.78)
(0.79)
(1.22)
(1.26)
100
70
35
15
17,5
50
125
100
86
15
43
50
55
40
125
110
86
2,5
22,5
30
7
7
7
28
40
47,5
69
55
125
110
86
2
27,5
35
28
40
47,5
(4.92)
(3.39)
(Ø0.28)
(1.10)
(1.57)
(1.87)
(4.33)
(0.08)
(1.08)
(1.38)
(2.72)
(2.17)
(1.57)
(4.92)
(3.39)
(1.18)
(0.89)
(0.10)
(2.17)
(1.57)
(Ø0.28)
(1.10)
(1.87)
(4.33)
(Ø4.92)
(3.94)
(3.94)
(3.39)
(2.76)
(1.38)
(0.59)
(0.59)
(0.69)
(1.97)
(1.97)
(0.28)
(1.69)
PCL402 Housing and mounting plates
M2 mounting plate M4 mounting plate M6 mounting plate
Number of sections L mm L inch
1 35 1.38
2 70 2.76
3 105 4.13
4 140 5.51
5 175 6.89
6 210 8.27
Section 1 Section 6 * Applies to M2, M3, M4 and M6
Valve housing with bottom
connection of pump and tank
Valve housing with side
connection of pump and tank
Control pres-
sure port B
Control
pressure
port A
M3 mounting plate
Pump connection
Tank connection
Ø6.5 mm (0.26 inch) hole
for cable passage
Tank
connection
Pump
connection
Ø6.5 mm (0.26 inch)
hole for cable passage
Ø6.5 mm (0.26 inch)
hole for cable passage
Mounting hole, min
Ø92 mm (3.62 inch)
Ø6.5 mm (0.26 inch)
hole for cable passage
(inch)
Dimensional Drawings
Remote Controls – Hydraulic
PCL4
16
Catalogue HY17-8357/UK
Parker Hannifin
Mobile Controls Division Europe
Borås, Sweden
11˚
155˚
74 (2.91)
56 (2.20)
23
24
11˚
29
31,5
102 (4.02)
30
81 (3.19)
M16-6H*
130 (5.12)
290 (11.42)
56 (2.20)
71 (2.80)
44,5 (1.75)
D101811C
(0.94)
(0.91)
(1.18)
(1.14)
(1.24)
90 (3.54)
90 (3.54)
80 (3.15) 80 (3.15)
Ø9 (Ø0.35)
32 (1.26)32 (1.26)
20 (0.79)
20 (0.79)
71 (2.80)
130 (5.12)
130 (5.12)
72 (2.83)
52 (2.05)
30 (1.18)
4
11°
23
24
11°
(091)
(0.94)
(0.16)
PCL402 Pedal F and M5 mounting plate
For housing dimensions, see page 15
mounting hole
M5 mounting plate
Port A Port B
PCL402 Pedal A36
* Bracket for lever attachment (if
required)
Port A Port B
(inch)
Dimensional Drawings
Remote Controls – Hydraulic
PCL4
17
Catalogue HY17-8357/UK
Parker Hannifin
Mobile Controls Division Europe
Borås, Sweden
(290) [11.42]
160 (6.30)
110 (4.33)
3 (0.12)
55 (2.17)
110 (4.33)
55 (2.17)
80 (3.15)
3
19,5
39 (1.54)
37 (1.46)
41 (1.61)
55 (2.17)
82 (3.23)
163 (6.42)
140 (5.51)
112 (4.41)
11°
11°
Ø10
Ø10 (Ø0.39)
30
12
10
52°
98°
49 (1.93)
22 (0.87)
6 (0.24)
R15 (R0.59)
9 (0.35)
9 (0.39)
113 (4.45)
150 (5.91)
50 (1.97)
30 (1.18)
15 (0.59)
4
150 (5.91)
(0.12)
(0.77)
(1.18)
(0.47)
(0.39)
(Ø0.39)
(0.16)
PCL402 Pedal A95
For housing dimensions, see page 15
M10x22 screw for mounting
of valve in cab
Space intended for floor mat,
thickness 12-15 mm
Gas damper fitted here
(if required)
Bellows
Port APort B
Lever fitted here
(if required)
(inch)
Dimensional Drawings
Remote Controls – Hydraulic
PCL4
18
Catalogue HY17-8357/UK
Parker Hannifin
Mobile Controls Division Europe
Borås, Sweden
Notes
Remote Controls – Hydraulic
PCL4
19
Catalogue HY17-8357/UK
Parker Hannifin
Mobile Controls Division Europe
Borås, Sweden
Your local authorized Parker distributor
Ed. 2015-04-21
EMEA Product Information Centre
Free phone: 00 800 27 27 5374
(from AT, BE, CH, CZ, DE, DK, EE, ES, FI, FR, IE, IL,
IS, IT, LU, MT, NL, NO, PL, PT, RU, SE, SK, UK, ZA)
US Product Information Centre
Toll-free number: 1-800-27 27 537
www.parker.com
Parker Worldwide
Europe, Middle East, Africa
AE – United Arab Emirates,
Dubai
Tel: +971 4 8127100
parker.me@parker.com
AT – Austria, Wiener Neustadt
Tel: +43 (0)2622 23501-0
parker.austria@parker.com
AT – Eastern Europe, Wiener
Neustadt
Tel: +43 (0)2622 23501 900
parker.easteurope@parker.com
AZ – Azerbaijan, Baku
Tel: +994 50 22 33 458
parker.azerbaijan@parker.com
BE/LU – Belgium, Nivelles
Tel: +32 (0)67 280 900
parker.belgium@parker.com
BG – Bulgaria, Soa
Tel: +359 2 980 1344
parker.bulgaria@parker.com
BY – Belarus, Minsk
Tel: +48 (0)22 573 24 00
parker.poland@parker.com
CH – Switzerland, Etoy
Tel: +41 (0)21 821 87 00
parker.switzerland@parker.com
CZ – Czech Republic, Klecany
Tel: +420 284 083 111
parker.czechrepublic@parker.com
DE – Germany, Kaarst
Tel: +49 (0)2131 4016 0
parker.germany@parker.com
DK – Denmark, Ballerup
Tel: +45 43 56 04 00
parker.denmark@parker.com
ES – Spain, Madrid
Tel: +34 902 330 001
parker.spain@parker.com
FI – Finland, Vantaa
Tel: +358 (0)20 753 2500
parker.nland@parker.com
FR – France, Contamine s/Arve
Tel: +33 (0)4 50 25 80 25
parker.france@parker.com
GR – Greece, Athens
Tel: +30 210 933 6450
parker.greece@parker.com
HU – Hungary, Budaoers
Tel: +36 23 885 470
parker.hungary@parker.com
IE – Ireland, Dublin
Tel: +353 (0)1 466 6370
parker.ireland@parker.com
IT – Italy, Corsico (MI)
Tel: +39 02 45 19 21
parker.italy@parker.com
KZ – Kazakhstan, Almaty
Tel: +7 7273 561 000
parker.easteurope@parker.com
NL – The Netherlands, Oldenzaal
Tel: +31 (0)541 585 000
parker.nl@parker.com
NO – Norway, Asker
Tel: +47 66 75 34 00
parker.norway@parker.com
PL – Poland, Warsaw
Tel: +48 (0)22 573 24 00
parker.poland@parker.com
PT – Portugal, Leca da Palmeira
Tel: +351 22 999 7360
parker.portugal@parker.com
RO – Romania, Bucharest
Tel: +40 21 252 1382
parker.romania@parker.com
RU – Russia, Moscow
Tel: +7 495 645-2156
parker.russia@parker.com
SE – Sweden, Spånga
Tel: +46 (0)8 59 79 50 00
parker.sweden@parker.com
SK – Slovakia, Banská Bystrica
Tel: +421 484 162 252
parker.slovakia@parker.com
SL – Slovenia, Novo Mesto
Tel: +386 7 337 6650
parker.slovenia@parker.com
TR – Turkey, Istanbul
Tel: +90 216 4997081
parker.turkey@parker.com
UA – Ukraine, Kiev
Tel: +48 (0)22 573 24 00
parker.poland@parker.com
UK – United Kingdom, Warwick
Tel: +44 (0)1926 317 878
parker.uk@parker.com
ZA – South Africa, Kempton Park
Tel: +27 (0)11 961 0700
parker.southafrica@parker.com
North America
CA – Canada, Milton, Ontario
Tel: +1 905 693 3000
US – USA, Cleveland
(industrial)
Tel: +1 216 896 3000
US – USA, Elk Grove Village
(mobile)
Tel: +1 847 258 6200
Asia Pacific
AU – Australia, Castle Hill
Tel: +61 (0)2-9634 7777
CN – China, Shanghai
Tel: +86 21 2899 5000
HK – Hong Kong
Tel: +852 2428 8008
ID – Indonesia, Tangerang
Tel: +62 21 7588 1906
IN – India, Mumbai
Tel: +91 22 6513 7081-85
JP – Japan, Fujisawa
Tel: +81 (0)4 6635 3050
KR – South Korea, Seoul
Tel: +82 2 559 0400
MY – Malaysia, Shah Alam
Tel: +60 3 7849 0800
NZ – New Zealand, Mt Wellington
Tel: +64 9 574 1744
SG – Singapore
Tel: +65 6887 6300
TH – Thailand, Bangkok
Tel: +662 186 7000
TW – Taiwan, New Taipei City
Tel: +886 2 2298 8987
VN – Vietnam, Ho Chi Minh City
Tel: +84 8 3999 1600
South America
AR – Argentina, Buenos Aires
Tel: +54 3327 44 4129
BR – Brazil, Cachoeirinha RS
Tel: +55 51 3470 9144
CL – Chile, Santiago
Tel: +56 2 623 1216
MX – Mexico, Toluca
Tel: +52 72 2275 4200
Catalogue HY17-8357/UK, POD, 12/2015, ZZ© 2015 Parker Hannin Corporation. All rights reserved.