196
Measuring critical
system parameters
is essential
Reliable and continuous
control of the filter in all
applications
The FMU range of filter condition
indicators are designed for use on
a wide range of Parker filters and
competitive interchange filters.
Maximum pressure 420 bar.
A comprehensive range of high quality
indicators for mobile, industrial and
marine applications.
Product Features:
• TheFMUrangeoffilterconditionindicators,designedforuse
on a wide range of Parker filters.
• Accuratevisual,electronicorelectricalfiltercondition
feedback.
• Maximumpressure420bar.
• Mobile,industrialandmarineapplications.
Indicators Series
FMU Dp-Indicators and Pressure Indicators
Max 420 bar
Contact Information:
Parker Hannifin
Hydraulic Filter Division Europe
European Product
Information Centre
Freephone: 00800 27 27 5374
(from AT, BE, CH, CZ, DE, EE, ES,
FI, FR, IE, IT, PT, SE, SK, UK)
filtrationinfo@parker.com
www.parker.com/hfde
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK/FMU
196 197
Indicators Series
FMU Dp-Indicators and Pressure Indicators
Typical Applications
Industrial equipment
Mobile equipment
Marine/offshore applications
The Parker FMU Series
Differential Pressure Indicators
The FMU range of filter condition indicators, are
designed for use on a wide range of Parker filters
and suitable for competitive interchange (consult
Parker Filtration for details).
Ideal for giving accurate visual, electronic or
electrical feedback of filter element condition, in
order to facilitate effective maintenance and ensuring
hydraulic systems, marine/mobile or industrial are
protected from particulate contamination.
Features & Benefits
Features
Indicators fatigue tested to full
pressure rating
Cartridge screw-in type indicators
Visual, electrical and electronic
indicators available
Several indication settings
Visual indicators
Electrical indicator with
change-over switch
Electrical indicator with 4 LEDs
Programmable and ATEX certified
indicators available
Advantages
Reliable indicators for heavy duty applications
Easy mounting
Check element condition at a glance
Right style for the application
Optimized for each bypass setting
Local monitoring of the element condition
Option of Normally Open (N.0.) and Normally
Closed (N.C.) function
Thermal lock-out
Visual early warning with yellow LED
Pre-alarm with yellow LED and wired output
Alarm with red LED and wired output
Right indicators for special applications
Benefits
Reliable and continuous control of the
filter in all applications
Reliable sealing, no leakage
Optimises element life, prevents bypassing
Match your system’s electrical connections
Right indicator for application
Reliable low cost indicator
Approved for low voltage and high
voltage use including machine control
systems and PLC’s
No false alarm because of low
temperature oil
Allows time to schedule element change
Indicates upcoming element change
Clear indication for element change
Improved machine surveillance
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK/FMU
198
Specification
Maximum operating pressure:
420 bar (250 bar for aluminium).
Maximum differential pressure:
210 bar.
Working temperature range:
-20˚C to +85˚C with fluoroelastomer seals, -40°C to +85°C with nitrile
and EPDM seals.
Material of housing:
Brass, aluminium or stainless steel.
Seals:
Fluoroelastomer, Nitrile or EPDM.
Mounting torque:
max. 75 Nm
(max. 50 Nm for aluminium indicator body & filter housing)
The differential pressure values of
standard indicator models:
1.2 bar ± 0.2
1.5 bar ± 0.2
2.5 bar ± 0.3
5.0 bar ± 0.5
7.0 bar ± 0.5
8.5 bar ± 0.5
(Indicators for other differential pressure values are optional).
FMU Dp – Indicators are typically used with the following filters:
1.0 and 1.5 bar
2.5 bar
7.0 bar
1.2 and 2.5 bar
2.5 and 5.0 bar
U12H
U12H
U12H
U14M
U14H
Heavy duty filters: GS, SF1040, DF2035, DF2050, DFH2060, DF2070, DF2089, DF2110
Note: FMU-Block is required to connect indicator to filter.
Medium pressure filters series: 45M.
High pressure filters series: 70L, 70T, 70B, 5000, 7100 and 7200.
Heavy duty filter series: 130M, DF2145.
High pressure filters without bypass valve: 70L, 70T, 70B, 7100 and 7200.
Medium and low pressure filter series;
Note for PD Range only 2.5 bar indicators are available: 15CN, 40CN, 80CN, 22PD, 32PD, 15P,
30P, 40RF, 50RF, IL8, 12M, 22M, 16P, 26P, 36P. Also heavy duty filter DF40.
High pressure filters 18P, 28P, 38P, FDA, FDB
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK/FMU
198 199
Indicators Series
FMU Dp-Indicators and Pressure Indicators
FMUT Electrical
Operation
U14M model U14H model
U12H model
Low pressure
High pressure
ø24
55.5
27.5
3
/4-16 UNF-2A
Red colour
visible when
indicator on
Red colour
visible when
indicator on
Low pressure
High pressure
7
/8 - 14UNF - 2A
60
32
ø19.78 0.06
+
-
ø18.83 0.06
+
-
Note: Only FPUM3
visual auto reset available
for models U14M and
U14H. FMUM1 not
available.
7
/8 - 14UNF - 2A
Operation
M1-type push
here for reset
FMUM3 Visual Auto Reset/FMUM1 Visual Manual Reset
Contact configuration
Rated
voltage
Non-inductive load (A) Inductive load (A)
Inrush
current (A)
Resistive load Lamp load Inductive load Motor load
N.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O.
125VAC 5 1.5 0.7 3 2.5 1.3
20
max.
10
max.
250VAC 3 1.0 0.5 2 1.5 0.8
8VDC 5 2 5 4 3
14VDC 5 2 4 4 3
30VDC 4 2 3 3 3
125VDC 0.4 0.05 0.4 0.4 0.05
250VDC 0.2 0.03 0.2 0.2 0.03
Enclosure class IP65
Electrical connector DIN 43650
Overvoltage category II (EN61010-1)
P1-P2
No
connect
COM
Indication (N.O)
Normally closed (N.C)
Rotating part 360°
P1 high pressure
P2 low pressure
Fixed part
¾-16 UNF-2A
27.5 75
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK/FMU
200
FMUF Electronic
Contact configuration
NPN
Load
Load
max 300 mA
3
1
2
4
+V
0V
+10...36 Vdc
FMU F
NPN
Rotating part 360°
Green LED
Yellow LED’s
Red LED
High pressure
Low pressure
C
Fixed part
A
B
Note: Do not connect output terminals 1 or 2 directly (without load) to power
supply terminals, because this will damage the equipment.
Thermal lock-out (standard setting +20°C)
Indicator operates only when temperature is above setting.
Green LED is blinking if temperature is lower. (not in U12H)
U12H U14M U14H
A 98 105 105
B 27.5 32 32
C Ø16.2 Ø19.78 Ø18.83
±0.05 ± 0.06 ± 0.06
D
3
/4-16
7
/8-14
7
/8-14
UNF-2A UNF-2A UNF-2A
Load
Load
max 300 mA
3
1
2
4
+V
0V
FMU F
PNP
+10...36 Vdc
PNP
Low pressure
U14M model U14H model
High pressure
B
C
D
C
D
U12H model
Enclosure class IP65
Electrical connector DIN 43650, cable connection PG9 or optinally M12 4-pin
Input supply voltage +10 to 36 Vdc
*Indication output max. 300 mA/36 Vdc
Output type: N.O. or N.C./NPN or PNP
D
Programmable Dp-indicator
All settings adjustable (settings made via PC) Connections cable and software
available from Parker
• 4LEDsgivingvisualindication:
• Green(G):PowerON
• Yellow1(Y1):Pre-alarm1(presetting50%)
• Yellow2(Y2):Pre-alarm2(presetting75%)
• Red(R):Indication(presetting100%)
• twoindependentlyprogrammableindicationoutputs
• canbesetindependentlyfromeachotherandLEDsetting
• outputtype:NPNorPNP
• switchingtype:N.O.orN.C.
• settingrange:0,5...10bar
• thermallock-outrange:0...100°C
• includesamicrochipwithmemorylogs
• numberofalarms:max65535
• timeindicationon(output1):max1092hours
• timepoweron(runninghours):max7
1
/2 years
• uploadandresetviaPC
Safety feature: The 250 bar U14M indicator does not fit into the U14H cavity,
which is used in 420 bar filters
Dimensions: see FMUF electronic Dp-indicator
FMUL1 Programmable
Ind. press.
setting
LED status Output
G Y1 Y2 R
< 50 % -
50 % -
75 % active
100 % active
2
1
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK/FMU
200 201
Indicators Series
FMU Dp-Indicators and Pressure Indicators
Ordering Information
FMUX Indicator Information (see left)
Indicator type X1: ATEX Dp-indicator
Electronic indicator accordant with ATEX 94/9/EC directive:
(Ex) II 2 GD Eex mII T6.
Degree of protection IP66. X1 refers to PNP, N.O.
Other output options X2, X3 and X4 are available by request.
(Refer to electronic F Type).
L1 Indicator Information (see previous page)
Connection cable + software for programmable indicator L1
Connection cable for PC serial connection and software for indicator
settings and utilising memory logs.
Ordering Code: 905075030
General Information
Seal kits (fluoroelastomer) Ordering code
Indicators with thread connection U12H (former -F6) + S08 911045078
Indicators with thread connection U14M (former -W3) 911045086
Indicators with thread connection U14H (former -W6) 911045087
Product configurator
Box 1
Code
M1*
M3
T1
F1
F2
F3
F4
L1
X1
Differential pressure indicator
Visual manual reset
Visual autoreset
Electrical
Electronic 4 LED, PNP, N.O.
Electronic 4 LED, NPN, N.O.
Electronic 4 LED, PNP, N.C.
Electronic 4 LED, NPN, N.C.
Programmable with memory logs
Ex version
Filter type
Box 2
FMU
Box 2
M3
Box 3
K
Box 4
V
Box 5
M
Box 6
U14
Box 7
H
Box 8
Box 3
Code
B
V
E
N
Seal material
Nitrile
Fluorelastomer
EPDM
Neopren
Seal type
Box 4
Thread connection
3
/4" - 16UNF-2A
7
/8" - 14UNF-2A
SAE 8
Thread connection
Code
U12
U14
SO8
Box 6Box 5
Code
A
M
R
Indicator body
Aluminium (Box 7, code M)
Brass (Box 7, code M and H)
Stainless steel
Indicator body
Code
FMU
Indicator series
Filter monitoring unit
Code
Box 1
Standard settings:
a: U14M, former -W3
b: U14H, former -W6
c: U12H, former -F6
*Available only with U12 thread
Code
F
G
H
K
M
N
P
Indicator setting
1.0 bar (14 psi)
1.2 bar (17 psi)
1.5 bar (21 psi)
2.5 bar (35 psi)
5.0 bar (70 psi)
7.0 bar (98 psi)
8.5 bar (125 psi)
Indicator setting
Standard
c
a
c
a, b, c
b
c
Max pressure
CN, 15/30P & 22/32 PD Series
45M, 130M, 70P & 18/28/38P
EPF, EMDPF
Max Pressure
Code
M
H
Omit
Box 7
Options
Standard
Other options
Options
Code
omit
factory supplied
Box 8
Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection.
Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability.
Note: F and L type indicators. Non-standard thermal
lockout settings shown here.
A - class products
FMUX ATEX Approved Electronic
Specification:
• Equipmentcategory2(for
zone 1): Ex II 2 GD Eex m II T6
• Maxtemperature85°C
• SupplyVoltage:10–36Vdc
• Current300mA(max)
• I
kmax
: 1A
•Halogenfreecable
Cable 10 meter
Ø 32
57
HEX 24 (Ø 26.5 mm)
Available for all
thread connections
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK/FMU
202
Pressure Indicators for Low Pressure Filters
250 VAC electrical indicator 1.0 bar48 Vdc electrical indicator 1.0 barVisual pressure indicator
ETF Filter
Elec.rating
Thread connection
Elec.connection
Protection
Switch type
Code
42V / 2A
G
1
/
8
AMP terminal 6.3x0.8
IP65 (terminal IP00)
NO or NC
FMUS2EBMG02L (NO switch)
FMUS3EBMG02L (NC switch)
Specifications
G
1
/8 (BSP)
Ø
28
9
Protective cover
24 A/F
55
74
Indicator PS NO or NC pressure switch
Normally open contacts
Normally closed contacts
Visual indicator 1.2 bar
G
1
/8: code FMUG2EBPG02L
G
1
/8
67
(2.64)
31
(1.22)
10
(0.39)
HEX 27
(1.06)
30 (1.18) x30 (1.18)
74
(2.91)
38
(1.49)
10 (0.39)
56
(2.20)
44 (1.73)
40
(1.57)
32
(1.26)
Rotating
part 360°
Fixed part
G
1
/8K
HEX 24
(0.94)
G
1
/8K
C3
2 NO
1 NC
Code G2
mm (inches)
Code S2/S3
mm (inches)
Code S4
mm (inches)
N/A
Select either normally open (NO)
or normally closed (NC)
FMUG2EBPG02L
FMUS2FBMG02L
(NO switch)
or
FMUS3FBMG02L
(NC switch)
FMUS4FFAG02L
Option Description Connection/Voltage Wiring Part number
G2
S2/S3
S4
Visual indicator
1.0 bar
Electrical indicator
1.0 bar
Electrical indicator
1.0 bar
N/A
42 Vdc
max
250 Vac
max
1 NC
2 NO
3 C
Normally open contacts
Normally closed contacts
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK/FMU