Directional Control Valve
Series D3W (Parker), 4D02 (Denison)
2-37
Catalogue HY11-3500/UK
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
D3W stand_UK.INDD CM_21.01.2008.1
2
Characteristics
General
Design Directional spool valve
Actuation Solenoid
Size DIN NG10 / CETOP 05 / NFPA D05
Mounting interface DIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -25...+50
Weight [kg] 4.8 (1 solenoid), 6.3 (2 solenoids)
Hydraulic
Max. operating pressure [bar] P, A B: 350; T: 210 (DC), 105 (AC), 210 (AC Code “H“)
Fluid Hydraulic oil in accordance with DIN 51524 / 51525
Fluid temperature [°C] -25 ... +70
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
Flow max. [l/min] 150 (DC); 115 (AC)
Leakage at 50 bar [ml/min] Up to 20 per flow path, depending on spool
Static / Dynamic
Step response see table response time
Electrical characteristics
Duty ratio 100% ED; CAUTION: coil temperature up to 150 °C possible
Max. switching frequency [1/h] 10000
Protection class IP 65 in accordance with EN 60529 (plugged and mounted)
Code K J U G Y T
Supply voltage / ripple [V] 12 V = 24 V = 98 V = 205 V =
110V at 50Hz/
120V at 60Hz
230V at 50Hz/
240V at 60Hz
Tolerance supply voltage [%] ±10 ±10 ±10 ±10 ±5 ±5
Current consumption hold [A] 3 1.5 0.37 0.18 0.8 / 0.72 0.4 / 0.36
Current consumption in rush [A] 3 1.5 0.37 0.18 3.41 / 3.31 1.75 / 1.7
Power consumption hold [W] 36 36 36 36 88 / 86 88 / 86
Power consumption in rush [W] 36 36 36 36 375 / 397 385 / 408
Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461.
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
Technical data
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
The direct operated directional control valve size NG10
is available with both Parker (series D3W) and Denison
(series 4D02) model codes.
Both series are available with a soft shift option for smooth
operation. An additional orifice in the solenoid anchor
dampens the shifting time for D3W. For the 4D02 the
orifice is located in the valve body.