Direct Operated Proportional DC Valve
Series D3FB
D3FB UK.indd 27.07.22
3-17
Catalogue MSG11-3500/UK
Parker Hannin Corporation
3
Technical Data
General
Design Direct operated proportional DC valve
Actuation Proportional solenoid
Size NG10 / CETOP 05 / NFPA D05
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTF
D
value
1)
[years] 150
Weight (OBE) [kg] 6.5 (7.2)
Hydraulic
Max. operating pressure [bar] Ports P, A, B 350, T 210
Max. pressure drop PABT / PBAT [bar] 350
Fluid Hydraulic oil according to DIN 51524 ... 535, other on request
Fluid temperature [°C] -25...+60
Viscosity permitted [cSt] /
recommended [cSt] /
[mm
2
/s]
[mm
2
/s]
20...400
30...80
Filtration ISO 4406; 18/16/13
D3FB*0 (Spool/sleeve) D3FB*3 (Spool/body)
Nominal ow
at Dp=5 bar per control edge
2)
[l/min]
40 / 60 40 / 60 / 80
Leakage at 100 bar [ml/min] <100 <100
Opening point (OBE) [%] see ow characteristics (set to 10 command signal)
Static / Dynamic
Step response at 100 % step [ms] 40
Hysteresis [%] <4 <5
Temperature drift solenoid current [%/K] <0.02
Electrical characteristics
Duty ratio [%] 100 ED; CAUTION: Coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Solenoid Code “K“ Code “J“
Supply voltage [V] 12 24
Current consumption [A] 2.95 1.5
Resistance [Ohm] 3.84 16.25
Solenoid connection Connector as per EN 175301-803
Wiring min. [mm²] 3 x 1.5 recommended
Wiring lenght max. [m] 50 recommended
2)
Flow rate for dierent Dp per control edge: Q
x
= Q
Nom.
·
√
Dp
x
Dp
Nom.
1)
If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve elec-
tronics voltage supply is to be switched o by a suitable switching element with sucient reliability.