Direct Operated Proportional DC Valve
Series D3FB
D3FB UK.indd 27.07.22
3-14
Catalogue MSG11-3500/UK
Parker Hannin Corporation
3
Characteristics
D3FB OBE
D3FB OBE
D3FB
D3FB
D3FB*0 OBE
Spool/sleeve design
D3FB*3 OBE
Spool/body design
Parametrizing connection
The proportional directional valves D3FB (NG10) are
available with and without onboard electronics (OBE).
D3FB OBE
The digital onboard electronics is situated in a robust
metal housing, which allows the usage under rough en-
vironmental conditions.
The nominal values are factory set. The cable connection
to a serial RS232 interface is available as accessory.
D3FB for external electronics
The parameters can be saved, changed and duplicated in
combination with the digital power amplier PWD00A-400.
The valve parameters can be edited with the common
ProPxD software for both versions.
The D3FB valves can be ordered with spool/sleeve design
(D3FB*0) for maximum precision as well as spool/body
design (D3FB*3) for high nominal ow - see functional
limit curves for maximum ow capability.
Features
Spool/sleeve and spool/body
3 command options for D3FB OBE:
+/- 10 V, 4…20 mA, +/- 20 mA
High repeatability from valve to valve
Low hysteresis
Manual override
Digital onboard electronics
Main connection
(always on B-side)
Manual
override
Direct Operated Proportional DC Valve
Series D3FB
D3FB UK.indd 27.07.22
3-15
Catalogue MSG11-3500/UK
Parker Hannin Corporation
3
Ordering Code
DC
valve
Size
DIN NG10
CETOP 05
NFPA D05
Propor-
tional
control
Spool
type
Seal NBR
(other seal
compounds
on request)
D3FB*0: Spool/sleeve design
Code Spool type
Flow [l/min]
at Dp 5 bar
per metering edge
Overlap
E01M
E01S
40
60
E02M
E02S
40
60
B31M
B31S
Q
B
= Q
A
/2
40 / 20
60 / 30
B32M
B32S
Q
B
= Q
A
/2
40 / 20
60 / 30
SolenoidSpool
position
Design
D3FB*3: Spool/body design
Code Spool type
Flow [l/min]
at Dp 5 bar
per metering edge
Overlap
E01M
E01S
E01U
40
60
80
E02M
E02S
E02U
40
60
80
B31M
B31S
B31U
Q
B
= Q
A
/2 40 / 20
60 / 30
80 / 40
B32M
B32S
B32U
Q
B
= Q
A
/2 40 / 20
60 / 30
80 / 40
D3FB
Connector
as per EN
175301-803
without plug
1)
Code Design
0
Spool/sleeve
design
3
Spool/body
design
D3FB*0: Spool/sleeve design
Code Solenoid
K 12 V / 2.95 A
D3FB*3: Spool/body design
Code Solenoid
K 12 V / 2.95 A
J 24 V / 1.5 A
Design
series
(not required
for ordering)
D 3 F 0 N WB
1)
Please order connector separately, see chapter 3 accessories.
Code Design
C
E
K
For regenerative and hybrid function refer solution with sandwich and adaptor plates "A10-1664 / A10-1665L / H10-
1662 / H10-1666L" in chapter 12.
Standard
dynamics
standard
repeatability
D3FB UK.indd 27.07.22
3-16
Direct Operated Proportional DC Valve
Series D3FB OBE
Catalogue MSG11-3500/UK
Parker Hannin Corporation
3
Ordering Code
D3FB OBE (with onboard electronics)
Size
DIN NG10
CETOP 05
NFPA D05
Directional
control
valve
Spool
type
Spool
position
Seals NBR
(other seal
compounds
on request)
Options DesignInput
signal
Code Design
0
Spool/sleeve
design
3 Spool/body design
Proportional
control
D3FB*0: Spool/sleeve design
Code Spool type
Flow [l/min]
at Dp 5 bar
per metering edge
Overlap
E01M
E01S
40
60
E02M
E02S
40
60
B31M
B31S
Q
B
= Q
A
/2
40 / 20
60 / 30
B32M
B32S
Q
B
= Q
A
/2
40 / 20
60 / 30
D3FB*3: Spool/body design
Code Spool type
Flow [l/min]
at Dp 5 bar
per metering edge
Overlap
E01M
E01S
E01U
40
60
80
E02M
E02S
E02U
40
60
80
B31M
B31S
B31U
Q
B
= Q
A
/2 40 / 20
60 / 30
80 / 40
B32M
B32S
B32U
Q
B
= Q
A
/2 40 / 20
60 / 30
80 / 40
1)
Single solenoid always 0...+10 V respectively 4...20 mA.
2)
Factory set ±10 V on delivery.
Standard
dynamics
standard
repeatability
Design
series
(not required
for ordering)
D 3 F 0 NB
Code Design
C
E
K
For regenerative and hybrid function refer solution with sandwich and adaptor plates "A10-1664 / A10-1665L / H10-
1662 / H10-1666L" in chapter 12.
Please order connector separately, see chapter 3 accessories.
Parametrizing cable OBE ® RS232: Item no. 40982923
Code Input signal
1)
Function Port Options
F0 0...+/-10 V
0...+10 V > P-A
6 + PE
Potentiometer
supply
G0 0...+/-20 mA
0...+20 mA > P-A
6 + PE
S0 4...20 mA
12...20 mA > P-A
6 + PE
W5
2)
0...+/-10 V
4...20 mA
0...+10 V > P-A
12...20 mA > P-A
11 + PE
Command
channel &
potentiometer
supply
Direct Operated Proportional DC Valve
Series D3FB
D3FB UK.indd 27.07.22
3-17
Catalogue MSG11-3500/UK
Parker Hannin Corporation
3
Technical Data
General
Design Direct operated proportional DC valve
Actuation Proportional solenoid
Size NG10 / CETOP 05 / NFPA D05
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTF
D
value
1)
[years] 150
Weight (OBE) [kg] 6.5 (7.2)
Hydraulic
Max. operating pressure [bar] Ports P, A, B 350, T 210
Max. pressure drop PABT / PBAT [bar] 350
Fluid Hydraulic oil according to DIN 51524 ... 535, other on request
Fluid temperature [°C] -25...+60
Viscosity permitted [cSt] /
recommended [cSt] /
[mm
2
/s]
[mm
2
/s]
20...400
30...80
Filtration ISO 4406; 18/16/13
D3FB*0 (Spool/sleeve) D3FB*3 (Spool/body)
Nominal ow
at Dp=5 bar per control edge
2)
[l/min]
40 / 60 40 / 60 / 80
Leakage at 100 bar [ml/min] <100 <100
Opening point (OBE) [%] see ow characteristics (set to 10 command signal)
Static / Dynamic
Step response at 100 % step [ms] 40
Hysteresis [%] <4 <5
Temperature drift solenoid current [%/K] <0.02
Electrical characteristics
Duty ratio [%] 100 ED; CAUTION: Coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Solenoid Code “K“ Code “J“
Supply voltage [V] 12 24
Current consumption [A] 2.95 1.5
Resistance [Ohm] 3.84 16.25
Solenoid connection Connector as per EN 175301-803
Wiring min. [mm²] 3 x 1.5 recommended
Wiring lenght max. [m] 50 recommended
2)
Flow rate for dierent Dp per control edge: Q
x
= Q
Nom.
·
Dp
x
Dp
Nom.
1)
If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve elec-
tronics voltage supply is to be switched o by a suitable switching element with sucient reliability.
D3FB UK.indd 27.07.22
3-18
Direct Operated Proportional DC Valve
Series D3FB OBE
Catalogue MSG11-3500/UK
Parker Hannin Corporation
3
Technical Data
Electrical characteristics OBE
Vibration resistance [g] 10 Sinus 5...2000 Hz acc. IEC 68-2-6
10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27
Duty ratio [%] 100 ED; CAUTION: coil temperatures up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage/ripple DC [V] 18...30, ripple < 5 % e., surge free
Current consumption max. [A] 3.5
Pre fusing medium lag [A] 4.0
Input signal
Codes F0 & W5 voltage [V] +10...0...-10, ripple < 0.01 % e., surge free, Ri = 100 kOhm, 0...+10 V Þ P -> A
C o d e s S 0 & W 5 c u r r e n t [mA]
4...12...20, ripple < 0.01 % e., surge free, Ri = <250 Ohm, 12...20 mA Þ P -> A
< 3.6 mA = enable o,
> 3.8 mA = enable on (acc. to NAMUR NE43)
Code G0 [mA]
+20...0...-20, ripple < 0.01 % e., surge free, Ri = <250 Ohm, 0...+20 mA Þ P -> A
Dierential input max.
Codes F0, G0 & S0 [V]
30 for terminal D and E against PE (terminal G)
11 for terminal D and E against 0V (terminal B)
Code W5 [V]
30 for terminal 4 and 5 against PE (terminal PE)
11 for terminal 4 and 5 against 0V (terminal 2)
Channel recall signal [V] 0...2.5: o / 5...30: on / Ri = 100 kOhm
Adjustment ranges Min [%] 0...50
Max [%] 50...100
Ramp [s] 0...32.5
Interface RS 232, parametrizing connection 5pole
EMC EN 61000-6-2, EN 61000-6-4
Central connection
Codes F0, G0 & S0
Code W5
6 + PE acc. to EN 175201-804
11 + PE acc. to EN 175201-804
Wiring min.
Codes F0, G0 & S0
Code W5
[mm²]
[mm²]
7 x 1.0 (AWG16) overall braid shield
11 x 1.0 (AWG16) overall braid shield
Wiring length max. 50
Direct Operated Proportional DC Valve
Series D3FB
D3FB UK.indd 27.07.22
3-19
/ D3FB OBE
Catalogue MSG11-3500/UK
Parker Hannin Corporation
3
Characteristic Curves
Flow characteristics
D3FB external electronics
at Dp = 5 bar per metering edge
Spool type E01/02, B31/32
Functional limits
100 % command signal (symmetric ow). At asymmetric ow a reduced ow limit has to be considered.
D3FB*0 D3FB*3
All characteristic curves measured with HLP46 at 50 °C.
D3FB OBE
(set to opening point 10 %)
at Dp = 5 bar per metering edge
Spool type E01/02, B31/32
D3FB UK.indd 27.07.22
3-20
Direct Operated Proportional DC Valve
Series D3FB OBE
Catalogue MSG11-3500/UK
Parker Hannin Corporation
3
PE
-10 V
+10 V
18...30 V=
5
9
10
6
7
8
11
4
1
2
0V
preset
recall
µC
1
2
3
4
5
6
7
8
9
10
11
S1 S2 S3 S4
command
potentiometer-
supply
Reference
supply
voltage
0...+/-10 VW5:
Code F0
6 + PE acc. to EN 175201-804
Code W5
11 + PE acc. to EN 175201-804
Block Diagrams
Code G0, S0
6 + PE acc. to EN 175201-804
PE
-10 V
+10 V
18...30 V=
E
C
F
D
A
B
0V
command
potentiometer-
supply
G
µC
Reference
supply
voltage
0...+/-10 VF0:
PE
G0: 0...
S0: 4...12...20 mA
±20 mA
18...30 V=
E
D
AB
command
supply
voltage
G
µC
0V
Reference
D3FB UK.indd 27.07.22
3-21
Direct Operated Proportional DC Valve
Series D3FB OBE
Catalogue MSG11-3500/UK
Parker Hannin Corporation
3
Interface Program
ProPxD interface program
The ProPxD software permits comfortable parameter
setting for the module electronics. Via the clearly arranged
entry mask the parameters can be noticed and modied.
Storage of complete parameter sets is possible as well
as printout or record as a text le for further documenta-
tion. Stored parameter sets may be loaded anytime and
transmitted to other valves. Inside the electronics a non-
volatile memory stores the data with the option for recall-
ing or modication.
The PC software can be downloaded free of charge at
www.parker.com/isde – see page “Support" or directly at
www.parker.com/propxd.
Features
Comfortable editing of all parameters
Depiction and documentation of parameter sets
Storage and loading of optimized parameter adjust-
ments
Executable with all actual Windows
®
operating
systems from Windows
®
XP upwards
Plain communication between PC and electronics
via serial interface RS232C
The parametrizing cable may be ordered under item
no. 40982923.
Direct Operated Proportional DC Valve
Series D3FB
D3FB UK.indd 27.07.22
3-22
Catalogue MSG11-3500/UK
Parker Hannin Corporation
3
Dimensions
D3FB*C
Surface nish
NBR
BK385
4x M6x40
ISO 4762-12.9
13.2 Nm
±15 %
SK-D3FB
D3FB*KD3FB*E
D3FB UK.indd 27.07.22
3-23
Direct Operated Proportional DC Valve
Series D3FB OBE
Catalogue MSG11-3500/UK
Parker Hannin Corporation
3
Dimensions
D3FB*C OBE
Surface nish
NBR
BK385
4x M6x40
ISO 4762-12.9
13.2 Nm
±15 %
SK-D3FB
D3FB*K OBED3FB*E OBE