Pilot Operated Directional Control Valves
Series D31DW, D31NW, D*1VW
2-66
D3-D11 UK.indd RH 02.02.2015
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Technical Data
General
Design Directional spool valve
Actuation Solenoid
Series
D31DW D31NW D41VW D81/91VW D111VW
NG10 NG10 NG16 NG25 NG32
6.0 / 6.6 7.6 / 8.1 9.7 / 10.3 17.9 / 18.6 67.4 / 68.0
DIN 24340 A10 DIN 24340 A10 DIN 24340 A16 DIN 24340 A25 DIN 24340 A32
ISO 4401 ISO 4401 ISO 4401 ISO 4401 ISO 4401
NFPA D05 NFPA D05 NFPA D07 NFPA D08 NFPA D10
Size
Weight (1/ 2 solenoids) [kg]
Mounting interface
CETOP RP 121-H
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C]
[°C]
-25...+60 (without inductive position control)
0...+60 (with inductive position control)
MTTF
D
value [years] 75
Hydraulic
Max. operating pressure
[bar]
[bar]
Pilot drain internal: P, A B, X: 350; T, Y: 105
Pilot drain external: P, A B, T, X: 350; Y: 105
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C]
[°C]
-20 ... +70 (NBR: -25...+70), (without inductive position control)
0...+70 (with inductive position control)
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow max. [l/min]
150 170 300 700 2000
up to 100* 72...422* up to 200* up to 800* up to 5000*
n.a. see p/Q diagram see p/Q diagram see p/Q diagram n.a.
5 7 5
Leakage at 350 bar (per flow path) [ml/min]
*depending on spool
Opening pressure integral check valve
[bar]
Minimum pilot supply pressure [bar]
Static / Dynamic
Step response at 95 % [ms] Energized / De-energized
DC solenoids Pilot pressure 50 bar
60 / 40 50 / 60 95 / 65 150 / 170 470 / 390
55 / 40 50 / 60 75 / 65 110 / 170 320 / 390
55 / 40 50 / 50 60 / 65 90 / 170 210 / 390
55 / 40 50 / 50 60 / 65 85 / 170 200 / 390
40 / 30 30 / 50 75 / 55 130 / 155 450 / 375
35 / 30 30 / 50 65 / 55 90 / 155 300 / 375
35 / 30 30 / 50 40 / 55 70 / 155 190 / 375
35 / 30 30 / 50 40 / 55 65 / 155 180 / 375
100 bar
250 bar
350 bar
AC solenoids Pilot pressure 50 bar
100 bar
250 bar
350 bar
Electrical characteristics
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP 65 in accordance with EN 60529
(with correctly mounted plug-in connector)
Code K J U G Y T
Supply voltage / ripple [V] 12 V = 24 V = 98 V = 205 V =
110 V at 50 Hz/ 230 V at 50 Hz/
120 V at 60 Hz 240 V at 60 Hz
Tolerance supply voltage [%] ±10 ±10 ±10 ±10 ±5 ±5
Current consumption hold [A] 2.72 1.29 0.33 0.13 0.58 / 0.49 0.31 / 0.26
Current consumption in rush [A] 2.72 1.29 0.33 0.13 2.1 / 2.0 1.05 / 1.0
Power consumption hold [W] 32.7 31 31.9 28.2 64 / 59 VA 68 / 62 VA
Power consumption in rush [W] 32.7 31 31.9 28.2 231 / 240 VA 231 / 240 VA
Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461.
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.