Directional Control Valve
Series D1MW
2-33
D1MW UK.indd 25.03.24
Catalogue MSG11-3500/UK
Parker Hannin Corporation
2
Characteristics
General
Design Directional spool valve
Actuation Solenoid
Size DIN NG06 / CETOP 03 / NFPA D03
Mounting interface DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03
Mounting position Unrestricted, preferably horizontal
Ambient temperature [°C] -25...+60
MTTF
D
value [years] 150
Weight [kg] 1.5 (1 solenoid), 2.1 (2 solenoids)
Vibration resistance [g]
10 Sinus 5...2000 Hz acc. IEC 68-2-6
30 Random noise 20...2000 Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27
Hydraulic
Max. operating pressure [bar] P, A B: 350; T: 210
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20 ... +70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406; 18/16/13
Flow max. [l/min] 80 (see shift limits)
Leakage at 50 bar [ml/min] Up to 10 per ow path, depending on spool
Static / Dynamic
Step response at 95 % [ms]
Energized: 32
De-energized: 40
Electrical characteristics
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Max. switching frequency [1/h] 15000
Protection class
Standard (as per EN175301-803) IP65 acc. EN60529 (w. corr. mount. plug-in connector)
AMP Junior Timer IP67 in acc. with EN60529 (with correctly mounted plug-in connector)
DT04-2P “Deutsch” IP69K (with correctly mounted plug-in connector)
Code K J
Supply voltage [V] 12 V = 24 V =
Tolerance supply voltage [%] ±10 ±10
Current consumption hold [A] 2.72 1.29
Power consumption hold [W] 32.7 31
Solenoid connection
Connector as per EN 175301-803 (code W), AMP Junior Timer (code A),
DT04-2P “Deutsch“ connector (code J). Solenoid identication as per ISO 9461.
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
Technical data
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
With AMP Junior Timer
The D1MW is based on the D1VW series of directional
control valves size NG06, but oers additional corrosion
protection of the valve body, the solenoid coil and the
anchor tube as well as the typical solenoid con nections
for the mobile market such as AMP Junior Timer and
DT04-2P “Deutsch”.
Technical features
• High corrosion protection (optional)
• Solenoid connection:
- Standard (as per EN175301-803)
- AMP Junior Timer
- DT04-2P “Deutsch”
• Robust design for rough applications
• Extended manual override with rubber cover (optional)
Connector DT04-2P “Deutsch”