3-38
4DP02V-03-06_UK.INDD CM
Pilot Operated Proportional DC Valves
Series 4DP02V, 4DP03, 4DP06 (Denison)
Catalogue HY11-3500/UK
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
3
Technical Data
General
Design Pilot operated DC Valve
Actuation Proportional solenoid
Size
4DP02V
NG10
(CETOP 05)
4DP03
NG16
(CETOP 07)
4DP06
NG25
(CETOP 08)
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -20...+50
Weight [kg] 7.6 (1 sol.) 8.1 (2 sol.) 10.5 (1 sol.) 10.9 (2 sol.) 18.7 (1 sol.) 19.1 (2 sol.)
Hydraulic
Max. operating pressure [bar] Ports P, A, B, X max. 350 bar, T max. 15 bar
(350 at external drain) Y max. 15 bar
Fluid Hydraulic oil as per DIN 51524...535, other on request
Fluid temperature [°C] -20...+80
Viscosity
permitted [cSt] /
recommended [cSt] /
[mm
2
/s]
[mm
2
/s]
10...650
30
Filtration ISO 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
Flow nominal at ∆P=5 bar
per control edge * [l/min] 90/120 200 400
Leakage at 100 bar [ml/min] 100 200 600
Pilot supply pressure [bar] 20-350 (optimal dynamics at 50)
Pilot flow at 100bar [l/min] <1.2
Pilot flow, step response [l/min] 0.8 1.7 3.8
Static / Dynamic
Step response at 100% step [ms] 60 75 100
Hysteresis [%] <5
Electrical characteristics
Duty ratio [%] 100
Protection class IP65 in accordance with EN 60529 (plugged and mounted)
Solenoid Code G12
Supply voltage [V] 12
Current max. [A] 2.2
Resistance [Ohm] 3.7
Coil insulation class F (155 °C)
Solenoid connection Connector as per EN 175301-803
Wiring min. [mm²] 3x1.5 (AWG 16) overall braid shield
Wiring lenght max. [m] 50
* Flow rate for different ∆p per control edge: Q
x
= Q
Nom.
·
√
∆p
x
∆p
Nom.