Pilot Operated Directional Control Valves
Series 4D02V, 4D03, 4D06 (DENISON)
2-77
Catalogue HY11-3500/UK
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
4D_UK.INDD CM
2
Characteristics
The pilot operated directional valves 4D02V (NG10),
4D03 (NG16) and 4D06 (NG25) are offered under Deni-
son brand name. The 4D02V is a high flow version with
a maximum flow up to 170 l/min.
4D03 and 4D06 are based on the Parker D41 and D81
main stage with Denison 4D01 pilot valve.
4D02V
4D03 4D06
4D06
Pilot Operated Directional Control Valves
Series 4D02V, 4D03, 4D06 (DENISON)
2-78
Catalogue HY11-3500/UK
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
4D_UK.INDD CM
2
Ordering Code
4D
Directional
control valve
Spool
type
Body End capSpool
position
Size
Code End cap
03 Standard
09
With stroke adjust-
ment on both sides
3 position spools
Code Spool position
03
3 positions.
Spring centered to “0“.
05
2 positions.
Spring centered to “0“.
Energized to “b“.
06
2 positions.
Spring centered to “0“.
Energized to “a“.
2 position spools
Code Spool position
01
2 positions.
Spring offset to “b“.
Energized to “a“.
02
2 positions.
Spring offset to “a“.
Energized to “b“.
04
2 positions detent.
Operated in “a“ or “b“.
No centre or spring offset position.
Code Control
A 1 solenoid
B 2 solenoids
C
2 solenoids
and 2 pos. detent
pilot valve
Code Size
02 NG10
03 NG16
06 NG25
Code Body
V for 4D02
3 for 4D03/06
3 position spools
Code Spool type
a 0 b
01
02
03
07
08
09
10
13
14
46
55
56
2 position spools
Code Spool type
a b
11
51
Control
Pilot Operated Directional Control Valves
Series 4D02V, 4D03, 4D06 (DENISON)
2-79
Catalogue HY11-3500/UK
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
4D_UK.INDD CM
2
Further spool types, solenoid voltages, position control,
hydraulic and mechanical operation on request.
Ordering Code
Solenoid
voltage
Main stage
accessories
Pilot oil
supply and
drain options
Pilot
accessories
Design
series
Code Accessories
omit Without
1
Shifting time adjustment
(meter-in)
2
Shifting time adjustment
(meter-out)
4 Integral check valve in P
5
Shifting time adjustment
(meter-in)
integral check valve in P
8
Shifting time adjustment
(meter-out)
integral check valve in P
Code Pilot accessories
10 *
1.0 mm orifice
(Standard for 4D02V)
15 *
1.5 mm orifice
(Standard for 4D03/06)
Code Inlet Outlet
1 Internal Internal
2 Internal External
3 External Internal
4 External External
* in P port of pilot valve
Code Solenoid voltage
G0R 12V =
G0Q 24V =
GAR 98V =
GAG 205 =
W06 115V / 50Hz
W07 230V / 50Hz
Seals
Code Design series
A 4D02V
B 4D03, 4D06
Code Seals
1 NBR
5 FPM
Pilot Operated Directional Control Valves
Series 4D02V, 4D03, 4D06 (DENISON)
2-80
Catalogue HY11-3500/UK
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
4D_UK.INDD CM
2
Technical Data
General
Design Directional spool valve
Actuation Solenoid
Series
Size
Weight (1/ 2 solenoids) [kg]
Mounting interface
CETOP RP 121-H
Mounting position Unrestricted, preferably horizontal
Ambient temperature [°C] -20...+50
Hydraulic
Max. operating pressure [bar] Pilot drain internal: P, A B, X: 350; T, Y: 105 (4D02V: P, A, B, X: 315; T, Y: 140)
Pilot drain external: P, A B, T, X: 350; Y: 105 (4D02V: P, A, B: 315; T, X: 315; Y: 140)
Fluid Hydraulic oil in accordance with DIN 51524 / 51525
Fluid temperature [°C] -20 ... +80
Viscosity permitted [cSt] / [mm²/s] 10...650
Viscosity recommended [cSt] / [mm²/s] 30
Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
Flow max. [l/min]
Leakage at 350 bar (per flow path) [ml/min]
*depending on spool
Opening pressure integral check valve [bar]
Minimum pilot supply pressure [bar]
Static / Dynamic
Step response at 95% [ms] Energized / De-energized
DC solenoids Pilot pressure 50 bar
100 bar
250 bar
AC solenoids Pilot pressure 50 bar
100 bar
250 bar
Electrical characteristics
Duty ratio 100% ED; CAUTION: coil temperature up to 180 °C possible
Protection class IP 65 in accordance with EN 60529 (plugged and mounted)
Code G0R G0Q GAR GAG W06 W07
Supply voltage / ripple [V] 12 V = 24 V = 98 V = 205 V = 115V at 50Hz 230V at 50Hz/
Tolerance supply voltage [%] +5...-10 ±10 +5...-10 +5...-10 ±5 ±5
Power consumption hold [W] 31 31 31 31 264 VA 264 VA
Power consumption in rush [W] 31 31 31 31 264 VA 264 VA
Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461.
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
4D02V 4D03 4D06
NG10 NG16 NG25
7.6 / 8.1 9.6 / 9.9 17.8 / 18.2
DIN 24340 A10 DIN 24340 A16 DIN 24340 A25
ISO 4401 ISO 4401 ISO 4401
NFPA D05 NFPA D07 NFPA D08
50 / 60 95 / 65 150 / 170
(150 bar) 50 / 60 75 / 65 110 / 170
50 / 50 60 / 65 90 / 170
30 / 50 75 / 55 130 / 155
(150 bar) 30 / 50 65 / 55 90 / 155
30 / 50 40 / 55 65 / 155
170 300 700
72...422 up to 200* 350...800
n.a. see p/Q diagram see p/Q diagram
12 for spool with open centre position
13 for spool with closed centre position
5 5
Pilot Operated Directional Control Valves
Series 4D02V, 4D03, 4D06 (DENISON)
2-81
Catalogue HY11-3500/UK
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
4D_UK.INDD CM
2
Spool
Code
Curve number
P-A P-B P-T A-T B-T
01 3 3 7 4 3
02 3 3 2 4
03 3 3 2 5
07 4 6 6 4 10
08 2 3 4 4
09 2 2 1 4
10 2 3 4 4
11 5 3 2 5
13 2 4 1 4
14 4 3 2 4
46 8 9 7 9
51 6 4 3 6
55 7 8
56 4 9
4D02V
The flow curve diagram shows the flow versus pressure
drop curves for all spool types. The relevant curve number
for each spool type, operating position and flow direction
is given in the table below.
Flow Curve Diagrams
4D06
Spool
Code
Curve number
P-A P-B P-T A-T B-T
01 2 1 1 3 5
02 3 2 3 5
03 3 2 3 5
07 4 8 9 4 10
08 4 3 3 5
09 3 3 4 5
10 4 2 3 6
11 3 2 3 5
13 1 2 4 5
14 3 3 4 5
46 2 2 4 6
51 6 5 6 8
55 5 10 3
56 10 5 5
4D03
Spool
Code
Curve number
P-A P-B P-T A-T B-T
01 1 2 6 4 6
02 1 1 4 5
03 1 1 4 5
07 2 9 8 7 10
08 1 1 5 5
09 1 2 4 6
10 1 2 5 6
11 2 3 6 7
13 2 2 3 5
14 2 2 3 5
46 1 2 3 6
51 3 5 3 5
55 2 8 2
56 8 2 3
Pilot Operated Directional Control Valves
Series 4D02V, 4D03, 4D06 (DENISON)
2-82
Catalogue HY11-3500/UK
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
4D_UK.INDD CM
2
Integral Check Valve / Pilot Oil Options
Integral check valve in the P port
Mounting an integral check valve in the P port is neces-
sary to build up pilot pressure for valves with P to T con-
nection and internal pilot oil supply. The pressure differ-
ence at the integral check valve (see performance curves)
is to be added to all flow curves of the P port of the main
valve. Directional valves with an integral check valve are
available for the series 4D02V, 4D03 and 4D06.
Flow curve 4D06
Flow curve 4D03
Pilot oil inlet (supply) and outlet (drain)
Series 4D02V
Series 4D03
Series 4D06
Flow curve 4D02V
Pilot Operated Directional Control Valves
Series 4D02V, 4D03, 4D06 (DENISON)
2-83
Catalogue HY11-3500/UK
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
4D_UK.INDD CM
2
Dimensions
4D02V
The space necessary to remove the plug as per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
Surface finish
BK320
4x M10x50
2x M6x55
DIN 912 12.9
63 Nm ±15%
13.2 Nm ±15%
on request
4D03
Surface finish
BK385
4x M6x40
DIN 912 12.9
13.2 Nm on request
Pilot Operated Directional Control Valves
Series 4D02V, 4D03, 4D06 (DENISON)
2-84
Catalogue HY11-3500/UK
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
4D_UK.INDD CM
2
Dimensions
4D06
Surface finish
BK360
6x M12x75
DIN 912 12.9
108 Nm ±15% on request
The space necessary to remove the plug as per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.