Directional Control Valve
Series 4D01 (Denison)
2-15
Catalogue HY11-3500/UK
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
4D01_UK.INDD CM
2
Characteristics
General
Design Directional spool valve
Actuation Solenoid
Nominal size DIN NG06 / CETOP 03 / NFPA D03
Mounting interface DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03
Mounting position Unrestricted, preferably horizontal
Ambient temperature [°C] -25...+50
Weight [kg] 1 sol.: 1.4 (DC), 1.5 (AC) / 2 sol.: 1.7 (DC), 1.8 (AC)
Hydraulic
Max. operating pressure [bar]
[bar]
P, A B: 350
T: 210 (DC), 140 (AC)
Fluid Hydraulic oil in accordance with DIN 51524 / 51525
Fluid temperature [°C] -25 ... +70
Viscosity permitted [cSt] / [mm²/s] 10...650
Viscosity recommended [cSt] / [mm²/s] 30
Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
Flow max. [l/min] 80
Leakage at 50 bar [ml/min] Up to 10 per flow path, depending on spool
Static / Dynamic
Step response at 95% [ms] Energized: 46 (DC), 20 (AC) / De-energized: 27 (DC), 18 (AC) / Quick energized: 30 (DC)
Electrical characteristics
Duty ratio 100% ED; CAUTION: coil temperature up to 180 °C possible
Max. switching frequency [1/h] 16000 (DC), 7200 (AC)
Protection class IP 65 in accordance with EN 60529 (plugged and mounted)
Code G0R G0Q W06 W07
Supply voltage [V] 12 V = 24 V =
150 at
50Hz
230 at
50Hz
Tolerance supply voltage [%] +5...-10 +5...-10 +5...-10 +5...-10
Power consumption hold [W] 31 31 78 78
Power consumption in rush [W] 31 31 264 264
Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461.
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
Technical data
With electrical connections the protective conductor (PE ) must be connected according to the relevant regulations.
The Denison series 4D01 is a solenoid operated direc-
tional control valve size NG06 in 3-chamber design. It is
direct operated by wet pin solenoids.
The 4D01 is available with a Soft Shift option for smooth
operation. An additional orifice in the solenoid anchor
dampens the shifting time.