Catalogue HY11-3500/UK
Parker Hannifin Corporation
Characteristics
The direct operated directional valves series D1VW with
inductive position control are typically used in safety
relevant applications. The start or end position can be
monitored. The position control is available for single and
double solenoid valves.
The fail-safe position of the directional valve during power
failure is the spring offset or center position.
Please find detailed information on the machine directive
in the position paper in chapter 1.
Attention:
The adjustment of the position control is factory set
and sealed. Replacement and repairs can only be
undertaken by the manufacturer.
AB
D1VW*B
D1VW*C
D1VW*B
D1VW*B
D1VW*C
D1VW*C
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Ordering Code Single Solenoid Valve
Directional
control
valve
Wet pin
solenoid
3-chamber
valve
Spool
position
Spool
type
Size
DIN NG06
CETOP 03
NFPA D03
3 position spools
Code Spool type
a 0 b
001
002
003
1)
004
005
015
2)
016
076
078
2 position spools
Code Spool type
a b
020
026
3)
030
3)
3 position spools
Code Spool position
E
Operated in position “a“.
2 positions.
Spring offset in position “0“.
F
Spring offset in position “b“.
2 positions.
Operated in position “0“.
K
Operated in position “b“.
2 positions.
Spring offset in position “0“.
M
Spring offset in position “a“.
2 positions.
Operated in position “0“.
1)
Only available for spool position “E“ and “F“.
2)
Only available for spool position “K“ and “M“.
3)
Only available for spool position “B“ and “H“.
4)
To be used in combination with rectifier plugs at 120 VAC / 230 VAC power supply.
5)
Please order female connector M12x1 separately (see accessories, female connector M12x1 (order no.: 5004109).
6)
For hydraulic presses according to the safety regulations EN 693, solenoid option “T” (without manual override) and accessory “I4N” or “I5N” (start position monitored)
are required.
D 1 WV
2 position spools
Code Spool position
B
2 positions.
Spring offset in position “b“.
Operated in position “a“.
H
2 positions.
Spring offset in position “a“.
Operated in position “b“.
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Seals
Further spool types and voltages on request.
Ordering Code Single Solenoid Valve
Connector
as per EN
175301-803,
without plug
(please order
plug separately)
Design
series
(not required
for ordering)
Solenoid
voltage
Position
control
5)
Manual
override
option
Code Position control Spool position
I2N
End position
monitored side B
E, F, B
(Solenoid on a-side)
I5N
6)
Start position
monitored side B
I1N
End position
monitored side A
K, M, H
(Solenoid on b-side)
I4N
6)
Start position
monitored side A
Code Voltage
K 12 V=
J 24 V=
U
4)
98 V=
G
4)
205 V=
Code Manual override
omit
manual override
(Standard)
T
6)
without manual
override
W
Code Seals
N NBR
V FPM
Catalogue HY11-3500/UK
Parker Hannifin Corporation
3 position spools
Code Spool position
C
3 positions.
Spring offset in position “0“.
Operated in position “a“ or “b“.
2 position spools
Code Spool position
D
2)
2 positions.
Operated in position “a“ or “b“.
No center or offset position.
D 1 WV W
3 position spools
Code Spool type
a 0 b
001
002
003
1)
004
015
1)
2 position spools
Code Spool type
a b
020
Seals Connector
as per EN
175301-803,
without plug
(please order
plug separately)
Design
series
(not required
for ordering)
Solenoid
voltage
Position
control
5)
Manual
override
option
Directional
control
valve
Wet pin
solenoid
3-chamber
valve
Spool
position
Spool
type
Size
DIN NG06
CETOP 03
NFPA D03
Code Voltage
K 12 V=
J 24 V=
U
3)
98 V=
G
3)
205 V=
Code Manual override
omit
manual override
(Standard)
T
4)
without manual
override
Code Seals
N NBR
V FPM
Code Position control Spool position
I3N End positions C, D
I6N
4)
Start positions C
1)
Only for position control code “I6N“.
2)
Only for position control code “I3N“.
3)
To be used in combination with rectifier plugs at 120 VAC / 230 VAC power supply.
4)
For hydraulic presses according to the safety regulations EN 693, solenoid option “T” (without manual override) and accessory “I6N” (start positions) is required.
5)
Please order plug M12 x 1 separately. Straight plug recommended – no defined position possible for angled plug.
Further spool types and voltages on request.
Ordering Code Double Solenoid Valve
Catalogue HY11-3500/UK
Parker Hannifin Corporation
General
Design Directional spool valve
Actuation Solenoid
Size DIN NG06 / CETOP 03 / NFPA D03
Mounting interface DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -20...+60
MTTF
D
value [years] 150
Weight [kg] 1.8 (1 solenoid) / 3.8 (2 solenoids)
Hydraulic
Max. operating pressure [bar] P, A B: 350 ; T: 210
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20 ... +70
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow max. [l/min] 80 (see shift limits)
Leakage at 50 bar [ml/min] Up to 10 per flow path, depending on spool
Static / Dynamic
Step response at 95 % [ms] Energized: 32 ; De-energized: 40
Electrical characteristics
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Max. switching frequency [1/h] 15000
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code K J U G
Supply voltage [V] 12 V = 24 V = 98 V = 205 V =
Tolerance supply voltage [%] ±10 ±10 ±10 ±10
Current consumption [A] 2.72 1.29 0.33 0.13
Power consumption [W] 32.7 31 31.9 28.2
Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461.
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
Technical Data
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Position Control
Single solenoid valves
Electrical characteristics of position control as per IEC 61076-2-101 (M12x1)
Definitions
Start position monitored:
The valve is de-energized. The inductive switch gives a
signal at the moment when the spool leaves the spring
offset position (below 15 % spool stroke).
At the switching point the spool is located within the closed
position. It is secured that only the flow paths of the offset
position are granted.
The switch can only be located on the opposite side of the solenoid for direct operated valves.
Please order plug M12x1 separately (see accessories, plug M12x1; order no.: 5004109).
End position monitored:
The inductive switch gives a signal before the end position
is reached (above 85 % spool stroke).
M12 pin assignment
1 + U
S
19.2...28.8 V
2 Out B: normally open
3 0V
4 Out A: normally closed
Supply voltage [VDC] 24
Tolernace supply voltage [%] ±20
Ripple supply voltage [%] 10
Polarity protection [V] 300
Current consumption without load [mA] 20
Switching hysteresis [mm] <0.06
Max. output current per channel, ohmic [mA] 250
Ambient temperature [°C] -20 … +60
Protection IP65 acc. EN 60529 (with correctly mounted plug-in connector)
Min. distance to next AC solenoid [m] 0.1
Interface M12x1 to IEC 61076-2-101
CE conform EN 61000-4-2 / EN 61000-4-4 / EN 61000-4-6
1)
/ ENV 50140 / ENV 50204
1)
Only guaranted with screened cable and female connector
2
1
3
4
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Ambient temperature [°C] -20...+60
Supply voltage Us / ripple [V] 10...30 / ±10 %
Current consumption without load [mA] 10
Max. output current per channel, ohmic [mA] 200
Min. output load per channel, ohmic [kOhm] 100
Max. output drop at 0.2 A [V] 2
EMC EN61000-6-4 / EN61000-6-2
Min. distance to next AC solenoid [m] >0.1
Interface M12x1 acc. to IEC 61076-2-101
Wiring min. [mm²] 3 x 0.14 brad shield recommended
Wiring length max. [m] 50 recommended
Position Control
Double solenoid valves
Electrical characteristics of position control as per IEC 61076-2-101 (M12x1)
M12 pin assignment
1 Us 10...30 V
2 not connected
3 0 V
4 Out A: normally open
Definitions
Start position monitored:
The valve is de-energized. The inductive switch gives a
signal at the moment when the spool leaves the center
position (below 15 % spool stroke).
At the switching point the spool is located within the closed
position. It is secured that only the flow paths of the offset
position are granted.
End position monitored:
The inductive switch gives a signal before the end position
is reached (above 85 % spool stroke).
Please order plug M12 x 1 separately. Straight plug recommended – no defined position possible for angled plug.
Catalogue HY11-3500/UK
Parker Hannifin Corporation
026
005, 016
001,002
0
50
100
150
200
250
300
350
Supply pressure [bar]
Flow [l/min]
10 20 30 40 50 60 70 80
90
0
003, 004, 015
020, 030
Flow curve diagram
Performance Curves
Shift limit diagram
The diagram below specifies the shift limits. Valves with
spool position “F” or “M” can only be operated up to 70 %
of the limits. The specifications apply to a viscosity of 40
mm
2
/s and balanced flow conditions. The shift limits can
be considerably lower at unbalanced flow conditions. To
avoid flow rates beyond the shift limits, a plug-in orifice
can be inserted in the P-port.
Position „b“ Position „a“ Position „0“
Spool
P->A B->T P->B A->T P->A P->B A->T B->T P->T
001 2 2 2 2
002 1 4 1 4 1 1 5 5 2
003 3 4 3 6 7
004 2 3 2 3 7 7
005 2 2 2 2 12
015 3 6 3 4 7
016 2 2 2 2 12
020 B 4 4 2 3
026 B 4 4
030 B 2 3 1 2
The flow curve diagram shows the flow versus pressure
drop curves for all spool types. The relevant curve number
for each spool type, operating position and flow direction
is given in the table below.
All characteristic curves measured with HLP46 at 50 °C, 90 % U
nom
and warm solenoids.
All characteristic curves measured with HLP46 at 50 °C.
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Ø42
91.5
Ø9.5
AB
Ø5.5
46
93
69
22
242
271.5
No defined position
forfemale connector
134.5
46
93
69
Ø9.5
AB
Ø5.5
22
242
Ø42
271.5
No defined position
forfemale connector
Dimensions
Interface EN 175301-803, DC solenoid, without plug M12x1
1)
B, E, F -style
Interface EN 175301-803, DC solenoid, without plug M12x1
2)
C, D -style
1)
Please order plug M12x1 separately (see accessories, plug M12x1; order no.: 5004109).
2)
Please order plug M12x1 separately. Straight plug recommended – no defined position possible for angled plug.
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
The space necessary to remove the M12x1 female connector is at least 22 mm.
H, K, M -style
Surface finish
BK375
4x M5x30
ISO 4762-12.9
7.6 Nm
±15 %
NBR: SK-D1VW-N-91
FPM: SK-D1VW-V-91
Attention:
The adjustment of the position control is factory set and sealed. Replacement and repairs can only be un-
dertaken by the manufacturer.