6-31
Hydraulically Pilot Operated Check Valves
Series SVLE (Parker), C4V (Denison)
Catalogue HY11-3500/UK
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
6
SVLE-C4V_UK.INDD RH
Characteristics
Pilot operated check valves are available with both Parker
(series SVL) and Denison (series C4V) ordering codes.
Hydraulically pilot operated check valves allow free flow
from A to B. The counter-flow direction is blocked.
When pressure is applied to control port X, the ring
chamber flow from B to A is released.
Up to four different pilot control ratios are available (see
ordering code).
Function
When no pressure is applied to the X-port, the flow from
B to A is blocked, because the pressure in B is also in
effect on top of the poppet.
Pressurizing the X port relieves the area on top of the
poppet to the drain port and allows flow from B to A.
The seat design of the SVL valve series provides leak-free
separation of port A and B in the closed position.
Technical data
General
Nominal size
NG10 NG25 NG32
Subplate mounting ISO 5781
Mounting position Unrestricted
Ambient temperature [°C] -20...+80
Weight [kg] 2.8 4.6 6.1
Hydraulic
Max. operating pressure [bar] 350
Nominal flow [l/min] 150 270 450
Fluid Hydraulic oil to DIN 51524
Viscosity recommended [cSt]/[mm²/s] 30...50
permitted [cSt]/[mm²/s] 20...380
Fluid temperature recommended [mm²/s] 30...50
permitted [mm²/s] -20...+70
Filtration ISO 4406 (1999); 18/16/13
∆p/Q flow curve
must be connected to tank