Direct Operated Prop. Pressure Relief Valve
Series RE06M*W
4-47
RE06MW UK.INDD RH 04.08.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
4
Characteristics / Technical Data
Pressure relief valves of the series RE06M*W are direct
operated proportional valves typically used as remote
control valves for flow rates below 3 l/min.
Function
When the pressure in port P or A exeeds the pressure
setting at the solenoid, the cone opens to port T and limits
the pressure in port P to the adjusted level.
The optimum performance can be achieved in combina-
tion with the digital amplifier module PCD00A-400.
Features
• Direct operated with proportional solenoid
• Very low pressure adjustment of p
min
• 2 pressure ports, A and P
• Subplate mounting according to ISO 6264
• 4 pressure stages
Technical data
General
Nominal size DIN NG06 / CETOP03 / NFPA D03
Interface Subplate mounting according to ISO 6264
Mounting position as desired, horizontale mounting prefered
Ambient temperature [°C] -20 ... +70
MTTF
D
value [years] 150
Weight [kg] 1.8
Hydraulic
Max. operating pressure [bar] Ports P and A up to 350; port T 30
Pressure stages [bar] 105, 175, 250, 350
Nominal flow [l/min] See p/Q curves
Fluid Hydraulic oil as per DIN 51524 ... 51525
Viscosity, recommended [cSt] /
permitted [cSt] /
[mm²/s]
[mm²/s]
30 ... 80
12 ... 380
Fluid temperature [°C] -20 ... +60
Filtration ISO 4406 (1999), 18/16/13 (acc. NAS 1638:7)
Linearity [%] ±2.8
Repeatability [%] <±1
Hysteresis [%] ±1.5 of p
max
Electrical
Duty ratio [%] 100 ED
Protection class IP 65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Nominal voltage [V] 12 (2.3 A max. current), 16 (1.3 A max. current)
Coil resistance [Ohm] 4 at 20°C
Solenoid connection Connector as per EN 175301-803
Power amplifier, recommended PCD00A-400
Direct Operated Prop. Pressure Relief Valve
Series RE06M*W
4-48
RE06MW UK.INDD RH 04.08.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
4
Ordering Code
SealsPressure
stage
Solenoid
voltage
Plug
connection
EN 175301-
803
Design
series
(not required
for ordering)
Normaly
open
Code Pressure stage
10 up to 105 bar
17 up to 175 bar
25 up to 250 bar
35 up to 350 bar
External
electronics
Interface
ISO 6264
NG06Proportional
pressure
relief valve
Code Solenoid voltage
K 12 V, 2.3 A
X 16 V, 1.3 A
Code Seals
N NBR
V FPM
RE M W 2 1 W06
Direct Operated Prop. Pressure Relief Valve
Series RE06M*W
4-49
RE06MW UK.INDD RH 04.08.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
4
p/Q curves
Pressure stage 105bar
Characteristic Curves
Pressure stage 350bar
Min. adjusted pressure
Pressure stage 105bar
Pressure/signal curve
Pressure stage 105bar
Pressure stage 350bar
Pressure stage 350bar
All characteristic curves measured with HLP46 at 50°C.
Direct Operated Prop. Pressure Relief Valve
Series RE06M*W
4-50
RE06MW UK.INDD RH 04.08.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
4
Mounting pattern ISO 6264-03-04-*-97
Dimensions
RE06M*W
Surface finish Bolt kit
NBR FPM
BK 375 4x M5x30 DIN 912 12.9
7.6 Nm
±15%
SK-RE06MNW SK-RE06MVW
Port B: O-ring recess diameter
on valve body.