Parker Hanniļ¬n Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-5
Pilot Operated Pressure Relief Valve
Series R5V
R5V UK.INDD CM 09.08.11
G0R G0Q GAR GAG W30 W31
12V = 24V = 98V = 205V =
110 at 50Hz
120 at 60Hz
230 at 50Hz
240 at 60Hz
+5...-10 +5...-10 +5...-10 +5...-10 +5...-10 +5...-10
31 31 31 31 78 78
31 31 31 31 264 264
General
Size 06 (Ā¾") 08 (1") 10 (1Ā¼") 12 (1Ā½")
Mounting Flanged according to SAE 61 and SAE 62
Mounting position unrestricted
Ambient temperature [Ā°C] -20...+50
MTTF
D
value [years] 75
Weight R5V 2port [kg] 4.0 4.6 5.9 ā
R5V 3port [kg] 3.6 4.6 5.2 8.0
Hydraulic
Max. operating pressure [bar]
SAE61 Ports A, B 350 350 280 210
Port Y1 30 30 30 30
SAE62 Ports A, B 350 350 350 350
Port Y1 30 30 30 30
Pressure stages [bar] 105, 210, 350
Nominal ļ¬ow [l/min] 90 300 600 600
Fluid Hydraulic oil according to DIN 51524...51525
Fluid temperature [Ā°C] -20...+80
Viscosity, permitted [cSt] / [mm
2
/s] 10...650
recommended [cSt] / [mm
2
/s] 30
Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638:7)
Electrical (solenoid)
Duty ratio [%] 100
Solenoid connection Connector as per EN175301-803
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code
Supply voltage [V]
Tolerance supply voltage [%]
Power consumption hold [W]
in rush [W]
Response time [ms] Energized / De-energized AC: 20/18 , DC: 46/27
Max. switching frequency AC: up to 7200, DC: up to 16000 switchings/hour
Coil insulation class H (180 Ā°C)
Technical Data / Performance Curves
p/Q performance curve Minimum pressure curve
The performance curves are measured with external drain.
For internal drain the tank pressure has to be added to curve.
Technical data
All characteristic curves measured with HLP46 at 50Ā°C.