Parker Hanniļ¬n Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-21
Pilot Operated Pressure Reducing Valve
Series R5R
R5R UK.INDD CM 02.08.11
G0R G0Q GAR GAG W30 W31
12V = 24V = 98V = 205V =
110 at 50Hz
120 at 60Hz
230 at 50Hz
240 at 60Hz
+5...-10 +5...-10 +5...-10 +5...-10 +5...-10 +5...-10
31 31 31 31 78 78
31 31 31 31 264 264
General
Size 06 08 10
Mounting Flanged according to SAE 61
Mounting position unrestricted
Ambient temperature [Ā°C] -20...+50
MTTF
D
value [years] 75
Weight [kg] 4.0 4.6 5.9
Hydraulic
Max. operating pressure [bar]
Ports A, B, X1 350 350 280
Port Y1 30 30 30
Flow direction B Ā® A
Pressure stages [bar] 105, 210, 350
Nominal ļ¬ow [l/min] 90 300 500
Fluid Hydraulic oil according to DIN 51524...51525
Fluid temperature [Ā°C] -20...+80
Viscosity permitted [cSt] / [mm
2
/s] 10...650
recommended [cSt] / [mm
2
/s] 30
Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
Electrical
Duty ratio [%] 100
Solenoid connection Connector as per EN175301-803
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code
Supply voltage [V]
Tolerance supply voltage [%]
Power consumption hold [W]
in rush [W]
Response time [ms] Energized / De-energized AC: 20/18, DC: 46/27
Max. switching frequency AC: up to 7200, DC: up to 16000 switchings/hour
Coil insulation class H (180 Ā°C)
Technical Data