R4V-R6V UK.INDD RH 06.09.2011
Pilot Operated Pressure Relief Valves
Series R4V / R6V
4-30
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
4
G0R G0Q GAR GAG W30 W31
12V = 24V = 98V = 205V =
110V/50Hz
120V/60Hz
230V/50Hz
240V/60Hz
+5...-10 +5...-10 +5...-10 +5...-10 +5...-10 +5...-10
31 31 31 31 78 78
31 31 31 31 264 264
General
Nominal size 10 25 32
Interface Subplate mounting acc. ISO 6264 (DIN 24340)
Mounting position as desired, horizontal mounting prefered
Ambient temperature [°C] -20...+80
MTTF
D
value [years] 75
Weight Series R6V
Series R4V
[kg]
[kg]
5.9
4.4
7.2
6.2
9.2
7.7
Hydraulic
Max. operating pressure [bar] Ports P (or A) and X up to 350, port T (or B) and Y 30
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 250 500 650
Fluid Hydraulic oil according to DIN 51524 ... 51525
Viscosity, recommended [cSt] /
permitted [cSt] /
[mm²/s]
[mm²/s]
30 ... 50
20 ... 380
Fluid temperature [°C] -20 ... +70
Filtration ISO 4406 - (1999) ; 18/16/13 (acc. NAS 1638:7)
Electrical
Duty ratio [%] 100 ED; CAUTION: coil temperature up to 180 °C possible
Max. switching frequency [1/h] 16000 (DC), 7200 (AC)
Protection class IP 65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code
G0R G0Q GAR GAG W30 W31
12V = 24V = 98V = 205V =
110V/50Hz
120V/60Hz
230V/50Hz
240V/60Hz
+5...-10 +5...-10 +5...-10 +5...-10 +5...-10 +5...-10
31 31 31 31 78 78
31 31 31 31 264 264
Supply voltage [V]
Tolerance supply voltage
[%]
Power consumption hold [W]
in rush [W]
Solenoid connection Connector as per EN 175301-803
Wiring min. [mm
2
] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
Technical Data
R4V/R6V
General
Nominal size 10 25 32
Interface Subplate mounting acc. ISO 6264 (DIN 24340)
Mounting position as desired, horizontal mounting prefered
Ambient temperature [°C] -20...+80
MTTF
D
value [years] 75
Weight Series R6V
Series R4V
[kg]
[kg]
4.5
2.7
5.8
4.5
7.8
6.0
Hydraulic
Max. operating pressure [bar] Ports P (or A) and X up to 350, Port T (or B) and Y 30
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 250 500 650
Fluid Hydraulic oil according to DIN 51524 ... 51525
Viscosity, recommended [cSt] /
permitted [cSt] /
[mm²/s]
[mm²/s]
30 ... 50
20 ... 380
Fluid temperature [°C] -20 ... +70
Filtration ISO 4406 - (1999) ; 18/16/13 (acc. NAS 1638:7)
R4V/R6V with vent function