Pilot Operated Sequence Valve
Series R4S
4-85
R4S UK.INDD RH 06.09.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
4
Characteristics / Technical Data
Subplate mounted sequence valves series R4S enable
a hydraulic system to operate in a pressure sequence.
When the system pressure reaches the setting pressure
the valve opens and permits flow to the secondary sub-
system.
Features
• Pilot operated sequence valve
• Subplate mounting acc. to ISO 5781
• 3 pressure stages
• 3 adjustment modes
- hand knob
- acorn nut with lead seal
- Key knob
Technical data R4S
General
Nominal size 10 25 32
Interface Subplate mounting acc. ISO 5781
Mounting position as desired, horizontal mounting prefered
Ambient temperature [°C] -20...+80
MTTF
D
value [years] 75
Weight Series R4S [kg] 2.7 4.5 6.0
Hydraulic
Max. operating pressure [bar] Ports A, B and X 350, port Y depressurized
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 150 350 650
Fluid Hydraulic oil according to DIN 51524 ... 51525
Viscosity, recommended [cSt] /
permitted [cSt] /
[mm²/s]
[mm²/s]
30 ... 50
20 ... 380
Fluid temperature [°C] -20 ... +70
Filtration ISO 4406 (1999) 18/16/13 (acc. NAS 1638:7)