Pilot Operated Pressure Reducing Valve
Series R4R
4-95
R4R UK.INDD RH 06.09.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
4
Characteristics / Technical Data
Subplate mounted pressure reducing valves series R4R
are used to control the pressure in the secondary part of
the hydraulic system. Independent of the primary pres-
sure the secondary pressure is reduced to the pressure
setting. In order to avoid undesired motion the valves are
normally closed.
Features
• Pilot operated with manual adjustment
• Subplate mounting acc. to ISO 5781
• Normally closed to avoid unintended motion
• 3 pressure stages
• 3 adjustment modes
- hand knob
- acorn nut with lead seal
- Key lock
General
Nominal size 10 25 32
Interface Subplate mounting acc. ISO 5781
Mounting position as desired, horizontal mounting prefered
Ambient temperature [°C] -20...+80
MTTF
D
value [years] 75
Weight [kg] 4.8 7.2 13.5
Hydraulic
Max. operating pressure [bar] Ports A, B and X 350, port Y depressurized
Pressure stages [bar] 105, 210, 350
Nominal flow [l/min] 150 350 500
Fluid Hydraulic oil according to DIN 51524 ... 51525
Viscosity, recommended [cSt] /
permitted [cSt] /
[mm²/s]
[mm²/s]
30 ... 50
20 ... 380
Fluid temperature [°C] -20 ... +70
Filtration ISO 4406 (1999) 18/16/13 (acc. NAS 1638:7)
Technical data