39 Catalogue 4083-3/UK
Volumetric flow rate sensors
SCVF volume counter
Technical data
SCVF- 002 004 015 060 080 150 300
Flow measuring range (l/min) 0.01 to 2.0 0.02 to 4.0 0.2 to 15 0.4 to 60 0.4 to 80 0.6 to 150 1.0 to 300
Pressure range P
N
(bar) 400 315 400 400 400 315 315
Overload pressure P
O
(bar) 480 400 480 480 480 350 350
Connection G3/8 BSPP G3/8 BSPP G3/8 BSPP G1/2 BSPP G1/2 BSPP G1 BSPP G1 BSPP
Sound level dB (A) < 60 < 60 < 60 < 70 < 70 < 70 < 72
Resolution (pulses / litre) 40,000 25,000 4082 965 965 333.33 191
Frequency (Hz) @ FS 1333.33 1666.66 1020.5 965 1286.6 833.33 955
Accuracy
Deviation from characteristic
curve
± 0.5 % FS at 20 cSt.
Response time*) < 10 ms
Repeat accuracy 0.01 % FS
Substance ** Hydraulic oil (25 micron filter)
Material
Material 1.7139
Contains no non-ferrous
metal or silicone
Housing Steel
Seal FKM
EPDM on request
Ambient conditions
Ambient temperature 0 to +55 °C
Storage temperature -25 to +85 °C
Fluid temperature -30 to 120 °C
Viscosity range Refer to diagram p. 40
Protection degree IP65 DIN EN 60529
Electrical connection
Plug M12x1; 4-pole
Power supply V
+
+18 to +30 VDC
Current consumption < 28 mA
Output signal
0 to 20 mA ≙ 0 to FS l/min
Load ≤ 150 Ω
EM compatibility
Disturbance emissions EN 61000-6-3
Resistance to interference EN 61000-6-2
FS = Full scale value
*) In combination with a signal converter
**) When using other substances, please state the viscosity range and the type
of seals. (Attach the data sheet of the substance if possible)
Pin assignment
M12x1; 4-pole
PIN Assignment
1 V
+
2 Q signal
3 0 V / GND
4 –