B
B
B62
Parker Hanniļ¬n Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Sandwich Valves
Catalog MSG14-2500/US
General Description
Series PRM reducing valves are used to regulate
pressure in one area of a circuit below normal system
pressure. This style valve is well suited to perform this
function as it mounts directly below the directional
control valve.
Operation
These are "normally open" valves that allow ļ¬uid to
pass through the controlled port during typical opera-
tion. When downstream pressure rises above the
value set by an adjustable spring force, the control
pilot opens and allows the main spool to move from
a full open position. The main spool modulates to
maintain the desired "reduced pressure" downstream
of the valve. The PRM3 also has a relieving mode.
Features
ā¢
PRM sandwich style pressure reducing valves allow for
easy conļ¬guration of stack systems and can be used
to reduce pressure on the 'P' port, the 'A' port, or the 'B'
port.
ā¢
Four pressure adjustment options are available: slotted
screw, hexagon socket screw (PRM4), knob and locking
knob. (PRM6 only)
ā¢
Valve bodies are manufactured from steel which provide
extra strength and durability for longer life. Internal hard-
ened steel components also provide longer life.
Technical Information Series PRM
WARNING: This product can expose you to chemicals including Lead, Nickel (Metallic), or 1,3-Butadiene which are known to the State of California to
cause cancer, and Lead or 1,3-Butadiene which is known to the State of California to cause birth defects and other reproductive harm. For more information
go to www.P65Warnings.ca.gov.
Speciļ¬cations
PRM3 PRM4 PRM6
Mounting
Pattern
NFPA D05,
CETOP 5, NG 10
CETOP 07, NG 16
NFPA D08,
CETOP 8, NG 25
Minimum
Pressure
10 Bar (150 PSI) with rated ļ¬ow, 150 SSU oil, and ļ¬uid
temperature of 38Ā°C (100Ā°F).
1
Maximum
Pressure
345 Bar
(5000 PSI)
345 Bar
(5000 PSI)
345 Bar
(5000 PSI)
Minimum
Flow
3.78 LPM
(1 GPM)
3.78 LPM
(1 GPM)
Maximum
Flow
64 LPM
(17 GPM)
189 LPM
(50 GPM)
Pressure
Range
Code
07
17
25
35
Pressure Range
10 to 70 Bar (150 - 1000 PSI)
10 to 175 Bar (150-2500 PSI)
10 to 250 Bar (150 - 3500 PSI)
10 to 350 Bar (150 - 5000 PSI)
PRM3 / PRM4 / PRM6
Filtration
ISO 4406 (1999); 18/16/13 (meet NAS
1638:7)
Venting
Connecting the vent port to tank
allows the reducing valve to divert ļ¬ow
at minimum pressure.
Remote
Control
Remote control valve connected to the
vent port can be used to control the
pressure.
2
Drain
Line
Drain line from pilot valve is internally
connected to the tank port. Tank line
pressure is thus added to the valve
setting.
3
1
Change in ļ¬ow, temperature or ļ¬uid (SSU) rating will
affect valve minimum pressure.
2
Set main valve pressure 10 Bar (150 PSI) higher than
remote pilot.
3
It is important that the drain line connection be taken
into consideration when determining the minimum valve
setting.