2-85
D_P UK.indd 27.07.22
Catalogue MSG11-3500/UK
Parker Hannin Corporation
2
Characteristics
Technical data
D1VP*B*4L D1VP*90
Direct Operated Directional Control Valves
Series D1VP, D3DP, D4P, D9P, D11P
Hydraulically operated directional control valves are
available in 5 sizes:
D1VP*4L NG06 – operated via end caps
D1VP*90 NG06 – operated via end caps and mounting
interface (X, Y)
D3DP NG10 – operated via mounting interface (X, Y)
D4P NG16 – operated via mounting interface (X, Y)
D9P NG25 – operated via mounting interface (X, Y)
D11P NG32 – operated via mounting interface (X, Y)
Size NG06 (D1VP) is available in two dierent designs:
D1VP*4L for operating pressure >10 bar (over tank
pressure) with control ports in the end caps.
D1VP*90 for operating pressure >15 bar with control
ports in the end caps and mounting interface (X, Y).
All other series are operated only via mounting interface
(X, Y).
The shifting time is depending on the pilot pressure. For
safe operation the minimum pilot pressure has to be
ensured in all operating conditions. The maximum pilot
pressure varies from the maximum operating pressure
in some sizes.
D1VP*C*4L
D1VP*90
1)
Depending on spool, see shift limits.
2)
Depending on spool.
3)
> tank pressure.
General
Design Directional spool valve
Actuation Hydraulic
Series D1VP*4L D1VP*90 D3DP D4P D9P D11P
Size NG06 NG06 NG10 NG16 NG25 NG32
Weight [kg] 1.3 1.3 3.7 9.0 17.0 66.0
Mounting interface DIN 24340 A06 DIN 24340 A06 DIN 24340 A10 DIN 24340 A16 DIN 24340 A25 DIN 24340 A32
ISO 4401 ISO 4401 ISO 4401 ISO 4401 ISO 4401 ISO 4401
NFPA D03 NFPA D03 NFPA D05 NFPA D07 NFPA D08 NFPA D10
CETOP RP 121-H
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -25...+60
MTTF
D
value [years] 150
Hydraulic
Max. operating pressure [bar]
P, A B: 350; P, A B; T: 350; P, A B, T: 350; P, A B, T: 350; P, A B, T: 350; P, A B, T: 350;
T: 140 X, Y: 210 X, Y: 210 X, Y: 350 X, Y: 350 X, Y: 350
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20 ... +70 (NBR: -25...+70)
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow max. [l/min] 60
1)
60
1)
130 300 700 2000
Leakage at 350 bar (per ow path) [ml/min] up to 60
2)
up to 60
2)
up to 100
2)
up to 200
2)
up to 800
2)
up to 5000
2)
Operating pressure (min/max) [bar] 10
3)
/ 210 15 / 210 15 / 210 5 / 350 5 / 350 5 / 350
Pilot volume (start position to end position) [cm
3
] 0.59 0.34 1.1 4.2 12.3 59.7
Static / Dynamic
Step response The response times depend on the pilot oil pressure and on the speed of the increase /
decrease of the pilot pressure.
2-86
D_P UK.indd 27.07.22
Catalogue MSG11-3500/UK
Parker Hannin Corporation
2
Design
series
(not required
for ordering)
Ordering Code
Direct Operated Directional Control Valves
Series D1VP
Directional
control
valve
Size
DIN NG06
CETOP 03
NFPA D03
2 position spools
Code Spool type
a b
020
026
030
3 position spools
Code Spool type
a 0 b
001
002
004
006
008
1)
009
1)
3 position spools
3)
Code Spool position
C
3 positions.
Spring oset in position “0“.
Operated in position “a“ or “b“.
Standard
Spool type 008
and 009
E
Operated in
position “a“.
Operated in
position “b“.
2 positions.
Spring oset in position “0“.
F
Spring oset in
position “b“.
Spring oset in
position “a“.
2 positions.
Operated in position “0“.
K
Operated in
position “b“.
Operated in
position “a“.
2 positions.
Spring oset in position “0“.
M
Spring oset in
position “a“.
Spring oset in
position “b“.
2 positions.
Operated in position “0“.
2 position spools
3)
Code Spool position
B
Spring oset in position “b“.
Operated in position “a“.
D
Detent, operated in position “a“ or
“b“. No centre or oset position.
H
Spring oset in position “a“.
Operated in position “b“.
Pilot portSpool
type
Spool
position
Seals
Code Seals
N NBR
V FPM
Code Pilot port
4L
High tank pressure,
indirect operated via pilot
spool, 3-chamber
90
Direct operated via X, Y port
or pipe thread G¼,
5-chamber
Hydraulical-
ly operated
Further spool types and styles on request.
1)
Consider specic spool position.
2)
Depending on pilot port.
3)
Code 4L without ports X and Y.
PV1D
3-/5-
chamber
design
2)
2-87
D_P UK.indd 27.07.22
Catalogue MSG11-3500/UK
Parker Hannin Corporation
2
Ordering Code
Direct Operated Directional Control Valves
Series D3DP
Further spool types and styles on request.
Design
series
(not required
for ordering)
Directional
control
valve
Size
DIN NG10
CETOP 05
NFPA D05
5-chamber
design
2 position spools
Code Spool type
a b
020
026
030
101
3 position spools
Code Spool type
a 0 b
001
002
003
004
005
006
007
008
1)
009
1)
010
011
014
015
016
021
022
031
032
081
082
102
3 position spools
Code Spool position
C
3 positions.
Spring oset in position “0“.
Operated in position “a“ or “b“.
Standard
Spool type 008
and 009
E
Operated in
position “a“.
Operated in
position “b“.
2 positions.
Spring oset in position “0“.
F
Spring oset in
position “b“.
Spring oset in
position “a“.
2 positions.
Operated in position “0“.
K
Operated in
position “b“.
Operated in
position “a“.
2 positions.
Spring oset in position “0“.
M
Spring oset in
position “a“.
Spring oset in
position “b“.
2 positions.
Operated in position “0“.
2 position spools
Code Spool position
B
Spring oset in position “b“.
Operated in position “a“.
D
Detent, operated in position “a“ or
“b“. No center or oset position.
H
Spring oset in position “a“.
Operated in position “b“.
Pilot oil
supply and
drain external/
external
Spool
type
Spool
position
SealsHydraulical-
ly operated
Code Seals
N NBR
V FPM
1)
Consider specic spool position.
PD3D 2
2-88
D_P UK.indd 27.07.22
Catalogue MSG11-3500/UK
Parker Hannin Corporation
2
Ordering Code
Direct Operated Directional Control Valves
Series D4P, D9P, D11P
Spool
type
Spool
position
Hydraulical-
ly operated
Directional
control
valve
Size
Code Bore Size
4 Ø20 mm NG16
9 Ø32 mm NG25
11 Ø50 mm NG32
1)
Consider specic spool position.
2)
Only D4 and D9 available.
D P
3 position spools
D4
D9
D11
Code Spool type
a 0 b
001
002
003
004
005
006
007
009
1)
011
014
015
016
021
022
031
032
054
081
082
2 position spools
D4
D9
D11
Code Spool type
a b
020
026
030
3 position spools
Code Spool position
C
3 positions.
Spring oset in position “0“.
Operated in position “a“ or “b“.
Standard Spool type 009
E
Operated in
position “a“.
Operated in
position “b“.
2 positions.
Spring oset in position “0“.
F
Spring oset in
position “b“.
Spring oset in
position “a“.
2 positions.
Operated in position “0“.
K
Operated in
position “b“.
Operated in
position “a“.
2 positions.
Spring oset in position “0“.
M
Spring oset in
position “a“.
Spring oset in
position “b“.
2 positions.
Operated in position “0“.
R
2)
No centre in
oset position.
No centre in
oset position.
2 positions detent.
Operated in position “0“ or “b“.
S
2)
No centre in
oset position.
No centre in
oset position.
2 positions detent.
Operated in position “0“ or “a“.
No center in oset position.
2 position spools
Code Spool position
B
Spring oset in position “b“.
Operated in position “a“.
D
Detent, operated in position “a“ or
“b“. No centre or oset position.
H
Spring oset in position “a“.
Operated in position “b“.
2-89
D_P UK.indd 27.07.22
Catalogue MSG11-3500/UK
Parker Hannin Corporation
2
Ordering Code
Direct Operated Directional Control Valves
Series D4P, D9P, D11P
Seals
Design
series
(not required
for ordering)
AccessoriesPilot oil
supply and
drain external/
external
Code Seals
N NBR
V FPM
Code Accessories
omit
Standard valve
w/o accessories
3A
Pilot choke,
meter-out
3B
Pilot choke,
meter-in
3D
2)
Stroke adjustment
side B
3E
2)
Stroke adjustment
side A
3F
2)
Stroke adjustment
side A and B
2
Further spool types, styles and position control on request.
2-90
D_P UK.indd 27.07.22
Catalogue MSG11-3500/UK
Parker Hannin Corporation
2
Flow curves
Shift limits
Direct Operated Directional Control Valves
Series D1VP
Flow Curve Diagrams / Shift Limits
The ow curve diagram shows the ow versus pressure
drop curves for all spool types. The relevant curve number
for each spool type, operating position and ow direction
is given in the table below.
Position „b“ Position „a“ Position „0“
Spool P->A B->T P->B A->T P->A P->B A->T B->T P->T
001 2 2 2 2
002 1 4 1 4 1 1 5 5 2
004 2 3 2 3 7 7
006 1 4 1 4 7 7
020 4 4 2 3
026 4 4
030 2 3 1 2
P->B A->T P->A B->T P->A P->B A->T B->T P->T
008 4 5 4 5 8
009 5 5 6 7 7
All characteristic curves measured with HLP46 at 50°C.
Spool Shift limit [l/min]
001
60
002
004
006
020
030
008
40
009
026 20
2-91
D_P UK.indd 27.07.22
Catalogue MSG11-3500/UK
Parker Hannin Corporation
2
Direct Operated Directional Control Valves
Series D3DP
Flow Curve Diagrams
Flow curves
The ow curve diagram shows the ow versus pressure
drop curves for all spool types. The relevant curve number
for each spool type, operating position and ow direction
is given in the table below.
All characteristic curves measured with HLP46 at 50°C.
Position „b“ Position „a“ Position „0“
Spool P-A B-T P-B A-T P-A P-B A-T B-T P-T A-B
001 4 3 4 3
002 2 4 3 3 2 2 1 2 3 4
003 2 2 4 1 5
004 4 3 3 2 5 5 6
005 1 3 4 2 4
006 2 4 3 3 5 5 6
007 4 2 2 2 2 2 5
010 2 2
011 3 3 2 3 10 10 11
014 2 3 4 2 2 2 5
015 4 2 2 2 4
016 4 2 1 1 4
020 4 4 4 4
026 3 3
030 4 3 3 3
081 6 7 6 7
082 7 7 6 5 11 11 11
101 9 9 9 9
102 2 2 2 1 6 6 3 5 6 6
P-B A-T P-A B-T P-A P-B A-T B-T P-T A-B
008 4 2 5 6 8
009 2 5 2 6 8
Position „b“ Position „a“ Position „0“
P-A B-T A-B P-B A-T A-T
021 3 5 6 4 2
031 3 5 6 4 1 9
P-A B-T P-A P-B A-B B-T
022 5 4 5 2 6
032 5 2 5 2 6 9
2-92
D_P UK.indd 27.07.22
Catalogue MSG11-3500/UK
Parker Hannin Corporation
2
Flow Curve Diagrams
Direct Operated Directional Control Valves
Series D4P, D9P, D11P
Spool
Code
Curve number
P-A P-B P-T A-T B-T
001 1 1 4 5
002 1 2 6 4 6
003 1 2 5 6
004 1 1 5 5
005 2 2 3 5
006 1 2 3 6
007 1 1 6 4 5
009 2 9 8 7 10
011 1 1 4 5
014 1 1 6 4 5
015 1 2 4 6
016 2 2 3 5
020 3 5 3 5
021 2 8 2
022 8 2 3
026 3 5
030 2 3 6 7
054 2 3 6 7
D4P
D9P and D11P
Spool
Code
Curve number
P-A P-B P-T A-T B-T
D9 D11 D9 D11 D9 D11 D9 D11 D9 D11
001 3 5 2 5 3 4 5 1
002 2 5 1 5 1 5 3 4 5 1
003 4 2 3 6
004 4 5 3 5 3 4 5 1
005 1 2 4 5
006 2 2 4 6
007 3 1 7 3 5
009 4 3 8 3 9 2 4 3 10 1
011 3 2 3 5
014 1 2 8 3 5
015 3 3 4 5
016 3 3 4 5
020 6 5 5 5 6 3 8 1
021 5 10 3
022 10 5 5
026 6 5
030 3 5 2 5 3 4 5 1
054 5 5 4 1
The ow curve diagram shows the ow versus pressure
drop curves for all spool types. The relevant curve number
for each spool type, operating position and ow direction
is given in the table below.
All characteristic curves measured with HLP46 at 50°C.
D4P
D11P
D9P
2-93
D_P UK.indd 27.07.22
Catalogue MSG11-3500/UK
Parker Hannin Corporation
2
Dimensions
Direct Operated Directional Control Valve
Series D1VP
D1VP*90
D1VP*4L
Surface nish
BK375
4x M5x30
ISO 4762-12.9
7.6 Nm
±15 %
NBR: SK-D1VP-N-87
FPM: SK-D1VP-V-87
Surface nish
BK375
4x M5x30
ISO 4762-12.9
7.6 Nm
±15 %
NBR: SK-D1VP-N4-91
FPM: SK-D1VP-V4-91
2-94
D_P UK.indd 27.07.22
Catalogue MSG11-3500/UK
Parker Hannin Corporation
2
D4P
Direct Operated Directional Control Valves
Series D3DP, D4P
Dimensions
Surface nish
BK320
4x M10x60
2 x M6x55
ISO 4762-12.9
63 Nm ±15 %
13.2 Nm ±15 %
NBR: SK-D41VW-N-91
FPM: SK-D41VW-V-91
D3DP
Surface nish
BK385
4x M6x40
ISO 4762-12.9
13.2 Nm
±15 %
NBR: SK-D3DP-N-42
FPM: SK-D3DP-V-42
Ø11
88
121
Ø6.5
30
70
77
AB
92
94
11
134
165
101
63
Ø11
44.5
Stroke
adjustment
AB
B
A
2-95
D_P UK.indd 27.07.22
Catalogue MSG11-3500/UK
Parker Hannin Corporation
2
D9P
D11P
Dimensions
Direct Operated Directional Control Valves
Series D9P, D11P
Surface nish
BK360
6x M12x75
ISO 4762-12.9
108 Nm ±15 %
NBR: SK-D91VW-N-91
FPM: SK-D91VW-V-91
Surface nish
BK386
6x M20x90
ISO 4762-12.9
517 Nm ±15 %
NBR: SK-D111VW-N-91
FPM: SK-D111VW-V-91
198
200
20
254
59
31990
Ø22
AB
AB
230
76
Ø13.5
116
118
12
155
57
Stroke
adjustment
117
AB
B
A