Catalog HY15-3502/US
Pilot Operated Pressure Reducing Valve
Series PRH102
PC117
Check
Valves
Shuttle
Valves
Load/Motor
Controls
Flow
Controls
Pressure
Controls
Logic
Elements
Directional
Controls
Manual
Valves
Solenoid
Valves
Proportional
Valves
Coils &
Electronics
Bodies &
Cavities
Technical
Data
SH
CV
LM
FC
PC
LE
DC
MV
SV
PV
CE
BC
TD
Parker Hannifin Corporation
Hydraulic Cartridge Systems
Technical Information
Specifications
Rated Flow 56.3 LPM (15 GPM)
Maximum Inlet 380 Bar (5500 PSI)
Pressure
Maximum 350 Bar (5000 PSI)
Pressure Setting
Maximum Tank 350 Bar (5000 PSI)
Pressure
Maximum 0.94 LPM (0.25 GPM)
Drain Flow
Cartridge Material All parts steel. All operating
parts hardened steel.
Operating Temp. -45°C to +93.3°C (“D”-Ring)
Range/Seals (-50°F to +200°F)
-31.7°C to +121.1°C (Fluorocarbon)
(-25°F to +250°F)
Fluid Mineral-based or synthetic with
Campatibility/ lubricating properties at viscosities
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
Filtration ISO Code 16/13,
SAE Class 4 or better
Approx. Weight .23 kg (0.5 lbs.)
Cavity C10-3
(See BC Section for more details)
Form Tool Rougher NTF10-3R
Finisher NFT10-3F
Performance Curves
General Description
Pilot Operated Pressure Reducing
Valve. For additional information see
Technical Tips on pages PC1-PC6.
Features
•
Hardened, precision ground parts for durability
•
Low profile adapter for minimal space requirements
•
Fully guided poppet for more consistent reseat
•
Steel adapters are coated with yellow zinc dichromate for
protection from salt spray
•
Polyurethane “D”-Ring eliminates backup rings and
prevents hydrolysis
•
Internal screening protects pilot spring from debris
(1)
(3)
(2)
Pressure
(2)
Reg.
(1)
Drain/Vent
(3)
Flow (Q)
22.7
6
11.4
3
LPM
GPM
0
34.1
9
45.4
12
56.8
15
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
0
1000
276
345
138
207
69
Pressure, PSI
4000
5000
PSI Bar
2000
3000
Flow vs. Pressure (Through cartridge only)
Flow (Q)
34.1
9
11.4
3
22.7
6
LPM
GPM
0
45.4
12
56.8
15
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
0
100
20.7
27.6
13.8
6.9
300
400
PSI Bar
200
Pressure, PSI
Port 2 to 1