Catalog HY15-3502/US
P.O. Pressure Reducing/Relieving Valve
Series PRH081
PC123
Check
Valves
Shuttle
Valves
Load/Motor
Controls
Flow
Controls
Pressure
Controls
Logic
Elements
Directional
Controls
Manual
Valves
Solenoid
Valves
Proportional
Valves
Coils &
Electronics
Bodies &
Cavities
Technical
Data
SH
CV
LM
FC
PC
LE
DC
MV
SV
PV
CE
BC
TD
Parker Hannifin Corporation
Hydraulic Cartridge Systems
Technical Information
Specifications
Rated Flow 30 LPM (8 GPM)
Maximum Inlet 380 Bar (5500 PSI)
Pressure
Maximum 350 Bar (5000 PSI)
Pressure Setting
Maximum Tank 350 Bar (5000 PSI)
Pressure
Maximum 0.56 LPM (0.15 GPM)
Drain Flow
Cartridge Material All parts steel. All operating
parts hardened steel.
Operating Temp. -45°C to +93.3°C (“D”-Ring)
Range/Seals (-50°F to +200°F)
-31.7°C to +121.1°C (Fluorocarbon)
(-25°F to +250°F)
Fluid Mineral-based or synthetic with
Campatibility/ lubricating properties at viscosities
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
Filtration ISO Code 16/13,
SAE Class 4 or better
Approx. Weight .11 kg (.25 lbs.)
Cavity C08-3
(See BC Section for more details)
Form Tool Rougher NTF08-3R
Finisher NFT08-3F
Performance Curves
General Description
Pilot Operated Pressure Reducing/
Relieving Valve. For additional
information see Technical Tips on
pages PC1-PC6.
Features
Hardened, precision ground parts for durability
Low profile adapter for minimal space requirements
Fully guided pilot for more consistent reseat
Steel adapters are coated with yellow zinc dichromate for
protection from salt spray
Polyurethane “D”-Ring eliminates backup rings and
prevents hydrolysis
Internal screening protects pilot spring from debris
(2)
(3)
(1)
(1)
ReliefReg.
Pressure/
Inlet (2)
Tank
(3)
Flow (Q)
8
2
15
4
30
8
23
6
15
4
8
2
0
0
LPM
GPM
23
6
30
8
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
0
1000
2000
345
414
207
276
69
138
Pressure, PSI
5000
6000
PSI Bar
3000
4000
Flow vs. Regulated Pressure (Through cartridge only)
Relieving Reducing
Flow (Q)
15
4
8
2
LPM
GPM
0
23
6
30
8
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
Flow vs. Pressure Drop (Through cartridge only)
Port 2 to 1
0
100
20.7
27.6
13.8
6.9
300
400
PSI Bar
200
Pressure Drop ( P)
P.O. Pressure Reducing/Relieving Valve
Series PRH081
Catalog HY15-3502/US
PC124
Check
Valves
Shuttle
Valves
Load/Motor
Controls
Flow
Controls
Pressure
Controls
Logic
Elements
Directional
Controls
Manual
Valves
Proportional
Valves
Coils &
Electronics
Technical
Data
SH
CV
LM
FC
PC
LE
DC
MV
SV
PV
CE
BC
TD
Bodies &
Cavities
Solenoid
Valves
Parker Hannifin Corporation
Hydraulic Cartridge Systems
Technical Information
Dimensions
Millimeters (Inches)
Ordering Information
THIRD-ANGLE
PROJECTION
SealsPressure
Range
Adjustment
Style
Body
Material
Port
Size
Optional
Pressure
Setting
Code Body Material
Omit Steel
A Aluminum
Code Adjustment Style / Kit No.
F Fixed style, preset at factory.
K Knob Adjust (717784-10)
S Screw Adjust
T Tamper Resistant Cap (717943)
PRH081
08 Size
P.O. Pressure
Reducing/Relieving
Valve
* Add “A” for aluminum, omit for steel.
Code Port Size Body Part No.
Omit Cartridge Only
4P 1/4 NPTF (B08-3-*4P)
4T SAE-4 (B08-3-*4T)
6T SAE-6 (B08-3-*6T)
6B 3/8 BSPG (B08-3-*6B)
Code Seals / Kit No.
Omit “D”-Ring / (SK08-3)
N Nitrile / (SK08-3N)
V Fluorocarbon / (SK08-3V)
Code Pressure Range
10 6.9 - 69 Bar (100 - 1000 PSI)
Standard Setting:
34.5 Bar (500 PSI)
20 6.9 - 138 Bar (100 - 2000 PSI)
Standard Setting:
69 Bar (1000 PSI)
30 13.8 - 207 Bar (200 - 3000 PSI)
Standard Setting:
103.5 Bar (1500 PSI)
50 13.8 - 345 Bar (200 - 5000 PSI)
Standard Setting:
172.4 Bar (2500 PSI)
Optional Pressure Setting
Pressure ÷ 10
i.e. 235 = 2350 PSI
(Omit if standard setting is used)
Setting Range:
100 to 5000 PSI
Fixed Cap/Tamper Resistant Version
42.4
(1.67)
44.7
(1.76)
41.9
(1.65)
14.2
(.56)
(1)
(2)
(3)
7/8" Hex.
43-49 Nm
(32-36 lb. ft.)
Torque
Screw/Knob Version
(1)
(2)
(3)
25.4 (1.0)
Dia. Knob
36.6
(1.44)
36.6
(1.44)
3/4-16 UNF-2A
Thread
NOTE: For settings below 20.7 Bar (300 PSI), flow
rating is limited to 11.3 LPM (3 GPM).