Bulletin HY14-2502-B1/US
Supplement to Catalog HY14-2502/US
Series D*VW
91 Design
Directional Control Valves
Product Ordering Quick Reference
Effective: October 1, 2009
Supersedes: September 1, 2007
II
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1cvr.p65, dd
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND
PROPERTY DAMAGE.
This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users
having technical expertise.
The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance,
safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning
the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible
for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.
WARNING — USER RESPONSIBILITY
OFFER OF SALE
The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed
by the provisions stated in the "Offer of Sale".
SAFETY GUIDE
For safety information, see Safety Guide SG HY14-1000 at www.parker.com/safety or call 1-800-CPARKER.
III
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1cvr.p65, dd
Contents
Model No. Description Page
D1VW, D1VHW .................................................... Directional Control Standard Valves......................................... 1-3
D31DW, D31DHW, D31VW, D31VHW ................ Solenoid Directional Valves ...................................................... 5-8
D61VW, D61VHW ................................................ Solenoid Directional Valves .................................................... 9-12
D81VW, D81VHW ................................................ Solenoid Directional Valves .................................................. 13-16
D101VW, D101VHW ............................................ Solenoid Directional Valves .................................................. 17-20
Terms of Sale with Warranty Limitations ............................................................................................................ 21
Safety Guide ...................................................................................................................................................... 22-23
Series D*V (Design 91)
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
1
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Technical Information Series D1V (Design 91)
A
AB
B
PT
Specifications
Mounting Pattern NFPA D03, CETOP 3; NG 6
Mounting DIN 24340-A6
Interface ISO 4401-AB-03-4-A
CETOP R35H 4.2-4-03,
NFPA D03
Maximum P, A, B
Pressure 345 Bar (5000 PSI) Standard
207 Bar (3000 PSI) DC Low Watt
CSA
276 Bar (3750 PSI)
Tank:
103 Bar (1500 PSI) AC only
207 Bar (3000 PSI) DC or AC Rectified
Standard
207 Bar (3000 PSI) AC Optional
CSA
103 Bar (1500 PSI)
Leakage Rates* Maximum Allowable:
100 SSU @ 19.7 cc (1.2 Cu. in.) per Minute/Land @
49°C (120°F) 69 Bar (1000 PSI)*
73.8 cc (4.5 Cu. in.) per Minute/Land @
207 Bar (3000 PSI)*
*#008 and #009 Typical:
Spools may 4.9 cc (0.3 Cu. in.) per Minute/Land @
exceed these rates 69 Bar (1000 PSI)*
Consult Factory 26.2 cc (1.6 Cu. in.) per Minute/Land @
345 Bar (5000 PSI)
Spool Center Condition *
Orifice Closed Open 2-Position
Soft Shift Size Energize De-Energize Energize De-Energize Energize De-Energize
S2 0.020 125 ms 920 ms 200 ms 275 ms 51 ms 100 ms
S5 0.050 51 ms 675 ms 50 ms 27 ms 51ms 21 ms
Response Time
Response time (milliseconds) at 345 Bar (5000 PSI) is
32 LPM (8.5 GPM).
Solenoid Type Pull-In Drop-Out
AC 13 20
DC 8 Watt 61 22
or 10 Watt
DC 30 Watt 51 21
General Description
Series D1VW directional control valves are high
performance, 4-chamber, direct operated, wet armature
solenoid controlled, 3 or 4-way valves. They are available
in 2 or 3-position and conform to NFPA’s D03, CETOP 3
mounting patterns.
Features
Softshift available.
19 standard spool styles available (for other spools –
Consult Factory).
Proportional spools.
DC surge suppression.
Nine electrical connection options.
AC & DC lights available (CSA approval for solenoids and
lights).
Internally ground.
Easy access mounting bolts.
Waterproof (meets NEMA 4, up to IP67 on some models).
Explosion proof.
CSA approvals.
U.L. recognized available - Contact Division.
No tools required for coil removal.
AC rectified coils.
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
2
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Standard Valves
Bold: Designates Tier I products and options.
Non-bold: Designates Tier II products and options. These products will have longer lead times.
NFPA D03
CETOP 3
DIN NG6
D
Directional
Control Valve
Basic Valve Actuator Spool Style
Seal
Solenoid
Voltage
1V
Code Description
N Nitrile
V Fluorocarbon
E* EPR
* Contact HVD for availability.
Code Description
A* 24/50 VAC
D 120 VDC
G 198 VDC
J 24 VDC
K 12 VDC
L 6 VDC
N** 220/50 VAC
P** 110/50 VAC
Q* 100/60 VAC
QD 100/60 - 100/50 VAC
R 24/60 VAC
T 240/60 - 220/50 VAC
U 98 VDC
Y 120/60 - 110/50 VAC
Z 250 VDC
* High Watt Coil only.
** Explosion Proof only.
Code Description
W* Solenoid, Wet Pin,
Screw-in
HW* Reversed Wiring
Code Symbol
001
002
003
004
005
006
007
008*
009**
010
* 008, 020 & 026 spools have closed crossover.
** 009 & 030 spool have open crossover.
Code Symbol
011
014
015
016
020*
026*
030**
081
082
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
Code Description Symbol
B* Single solenoid, 2 position, spring offset.
P to A and B to T in offset position.
C Double Solenoid, 3 position, spring centered.
D** Double solenoid, 2 position, detent.
E Single solenoid, 2 position, spring centered.
P to B and A to T when energized.
F‡ Single solenoid, 2 position, spring offset,
energized to center. Position spool spacer on
A side. P to A and B to T in spring offset position.
H* Single solenoid, 2 position, spring offset.
P to B and A to T in offset position.
K Single solenoid, 2 position, spring centered.
P to A and B to T when energized.
M‡ Single solenoid, 2 position, spring offset,
energized to center position. Spool spacer on
B side. P to B and A to T in spring offset position.
* Spools 020, 026 and 030 only.
** Spools 020, 030 only.
High Watt only.
AB
PT
b
a
AB
PT
b
AB
PT
ba
AB
PT
b
AB
PT
b
AB
PT
a
AB
PT
a
AB
PT
a
Ordering Information Series D1V (Design 91)
* Valve schematic symbols are per NFPA/ANSI
standards, providing flow P to A when energizing
solenoid A. Note operators reverse sides for #008
and #009 spools. See installation information for
details. To configure per DIN standards (A coil
over A port, B coil over B port) code valves as
D1VHW***.
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
3
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Standard Valves
Bold: Designates Tier I products and options.
Non-bold: Designates Tier II products and options. These products will have longer lead times.
Code Description
Omit No Options
J* Diode Surge
Suppressor
Z† Rectified Coil
* DIN coil must have
plug with lights.
DC tube standard.
Code Description
Omit Standard Valve
3*† CSA USA
(UL 429)
4* CSA Approved
* Not available with AC
high pressure tube.
B, C, H styles only,
J, K, Y, U voltages only,
C, G, W solenoid
connections only.
Tube
Options
Approvals Design
Series
NOTE:
Not required
when ordering.
Manual
Override
Options
Coil
Options
Electrical
Options
Valve
Variations
Shift
Response
and
Indication
Code Description
5** Signal Lights
56* Manaplug (Mini) with Lights
7B* Manaplug (Micro) with Lights
1C* Manaplug (Mini) Single Sol. 5-pin,
with Lights
1D* Manaplug (Micro) Single Sol. 5-pin,
with Lights
1M* Manaplug Opposite of Normal
1P Painted Body
4D† Twist & Lock Override (Old 5426)
4E† Push Manual Override (Old x5450)
4F Heavy Duty Detent
7Y* 4-pin M12X1 Manaplug,
special wiring with Lights (Old B755)
* Plug-in Conduit Box.
** Plug-in, DIN, or DESINA only.
DC or AC Rectified only.
Not available with softshift.
Code Description
Omit Standard Pressure
103.5 Bar (1500 PSI) AC
207 Bar (3000 PSI) DC
H* High Pressure, AC only
207 Bar (3000 PSI)
* Not available with CSA.
Code Description
Omit Standard
P* Extended Manual Override
w/Body
T*† No Override
* Manual Override options not
available with Explosion Proof or
softshift.
DC or AC Rectified only.
Solenoid
Connection
Code Description
C††* Leadwire Conduit Box
D†‡
¤
Metric Plug (M12X1),
DESINA
E* Explosion Proof
G‡ Plug-In Conduit Box
J†* Deutsch (DT06-2S)
M†* Metri-Pack (150)
P DIN with Plug
S†* Double Spade
W* DIN w/o Plug
* Not available with lights.
DC Only.
††No variations – See Plug-in.
Must have lights.
¤
Must have Diode Surge
Suppressor.
Code Description
Omit Standard Response
S2* Softshift, 0.020" Orifice
S5* Softshift, 0.050" Orifice
I7** Monitor Switch Direct
Op. End Stroke
I8** Monitor Switch
Direct Op. Start Stroke
* Not available with 8 watt.
** B, E, H & K styles only.
Spools 8,9,21,26,81,82 not available.
Not CE or CSA approved.
Code Description
Omit High Watt
D#
¤
Explosion Proof,
EEXD ATEX
E#
¤
Explosion Proof,
EEXME ATEX
F** Low Watt
L*** 8 Watt
O# Explosion Proof,
MSHA
U#
¤
Explosion Proof,
UL/CSA
X* No Coils
* See solenoid voltage code
to specify proper tube.
** AC only.
*** DC or AC Rectified only.
AC ambient temperature
must not exceed
60°C (140°F).
# Explosion Proof – coils
are 60 Hz at Std. voltage.
Dual rating not available.
¤
Lights, softshift, and other
options are not available
on Explosion Proof coils.
Valve Weight:
Single Solenoid 1.36 kg (3.0 lbs.)
Double Solenoid 1.6 kg (3.5 lbs.)
Standard Bolt Kit: BK209
Metric Bolt Kit: BKM209
Ordering Information Series D1V (Design 91)
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
4
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Notes
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
5
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Technical Information Series D31V (Design 91)
General Description
Series D31*W directional control valves are 5-chamber,
pilot operated, solenoid controlled valves. The valves
are suitable for manifold or subplate mounting.
Response Time
Response time (milliseconds)
at 345 Bar (5000 PSI) is 76 LPM (20 GPM)
Solenoid Pilot
Type Pressure
Pull-In Drop-Out
500 40 50
DC 1000 36 50
2000 34 50
500 20 33
AC 1000 18 33
2000 13 33
Features
World design – Available worldwide.
Mounting bolts below center line of spool – Minimizes
spool binding.
Five chamber style – Eliminates pressure spikes in
tubes, increasing valve life.
High pressure and flow ratings – Increased
performance options in a compact valve.
Mounting Pattern NFPA D05H, CETOP 5
NFPA D05HE, CETOP 5H
Max. Operating 345 Bar (5000 PSI) Standard
Pressure 207 Bar (3000 PSI) DC Low Watt
CSA
207 Bar (3000 PSI)
Max. Tank Line Internal Drain Model:
Pressure 103 Bar (1500 PSI) AC Std.
207 Bar (3000 PSI) DC Std./AC Opt.
External Drain Model:
207 Bar (3000 PSI)
CSA
103 Bar (1500 PSI)
Max. Drain 103 Bar (1500 PSI) AC only
Pressure 207 Bar (3000 PSI) DC Std./AC Opt.
CSA
103 Bar (1500 PSI)
Min. Pilot Pressure 6.9 Bar (100 PSI)
Max. Pilot Pressure 345 Bar (5000 PSI) Standard
207 Bar (3000 PSI) DC Low Watt
CSA 207 Bar (3000 PSI)
Nominal Flow 76 Liters/Min (20 GPM)
Specifications
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
6
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
D
Directional
Control Valve
Actuator Spool Style
Seal
Solenoid
Voltage
Code Description
W* Solenoid, Wet
Pin,
Screw-in
HW* Reversed
Wiring
Pilot Supply
and Drain
Code Description
31D NFPA D05,
CETOP 5,
DIN NG10,
D03 Pilot,
ISO Port
31V NFPA D05,
CETOP 5,
DIN NG10
D03 Pilot,
NFPA Port
Code Description
A* 24/50 VAC
D 120 VDC
G 198 VDC
J 24 VDC
K 12 VDC
N** 220/50 VAC
Q* 100/60 VAC
R 24/60 VAC
T 240/60 - 220/50 VAC
U 98 VDC
Y 120/60 - 110/50 VAC
Z 250 VDC
* High Watt Coil only.
** Explosion Proof only.
Code Description
N Nitrile
V Fluorocarbon
Code Description
1 Internal Pilot, External Drain
2 External Pilot, External Drain
4* Internal Pilot, Internal Drain
5 External Pilot, External Drain
* Not available with 002, 007, 008, 009
and 014 spools.
Bold: Designates Tier I products and options.
Non-bold: Designates Tier II products and options. These products will have longer lead times.
Basic Valve
Code Symbol
001
002
003
004
005
006
007
008*
009**
010
* 008, 020 spools have closed crossover.
** 009 & 030 spool have open crossover.
Code Symbol
011
012
014
015
016
020*
030**
081
082
Code Description Symbol
B* Single solenoid, 2 position, spring offset.
P to A and B to T in offset position.
C Double Solenoid, 3 position, spring centered.
D** Double solenoid, 2 position, detent.
E Single solenoid, 2 position, spring centered.
P to B and A to T when energized.
F‡ Single solenoid, 2 position, spring offset,
energized to center. Position spool spacer on
A side. P to A and B to T in spring offset position.
H* Single solenoid, 2 position, spring offset.
P to B and A to T in offset position.
K Single solenoid, 2 position, spring centered.
P to A and B to T when energized.
M‡ Single solenoid, 2 position, spring offset,
energized to center position. Spool spacer on
B side. P to B and A to T in spring offset position.
* Only spools 020, 026 and 030.
** Only spools 020, 030 and 100.
High Watt only.
Ordering Information Series D31V (Design 91)
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
b
AB
PT
ba
AB
PT
b
a
AB
PT
b
AB
PT
a
AB
PT
b
AB
PT
a
AB
PT
a
* Valve schematic
symbols are per NFPA/
ANSI standards,
providing flow P to A
when energizing
solenoid A. Note
operators reverse sides
for #008 and #009
spools. See installation
information for details.
To configure per DIN
standards (A coil over A
port, B coil over B port)
code valves as
D1VHW***.
AB
PT
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
7
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Valve Weight: Double Solenoid 5.4 kg (12.0 lbs.)
Standard Bolt Kit: BK98
Tube
Options
Approvals
Design
Series
NOTE:
Not required
when
ordering.
Manual
Override
Options
Coil
Options
Electrical
Options
Shift
Response
and Indication
Valve
Variations
See next page
Code Description
Omit High Watt
D#
¤
Explosion Proof,
EEXD ATEX
E#
¤
Explosion Proof,
EEXME ATEX
F** Low Watt
L*** 8 Watt
O#
¤
Explosion Proof,
MSHA
U#
¤
Explosion Proof,
UL/CSA
X* No Coils
* See solenoid voltage
code to specify proper
tube.
** AC only.
*** DC or AC Rectified only.
# Explosion Proof – coils
are 60 Hz at Std. voltage.
Dual rating not available.
¤
Lights, softshift, and other
options are not available
on Explosion Proof coils.
Code Description
Omit Standard Valve
3*† CSA USA (UL 429)
4* CSA Approved**
* Not available with AC high
pressure tube.
** Valve is derated with this option.
B, C, H styles only. J, K, Y, U
voltages only with C, G, W
solenoid connections only.
Code Description
Omit No Options
J* Diode Surge
Suppressor
Z Rectified Coil
* DC or AC Rectified only.
DIN coil must include plug
with lights.
Bold: Designates Tier I products and options.
Non-bold: Designates Tier II products and options. These products will have longer lead times.
Solenoid
Connection
Code Description
C** Conduit Box
D*^
¤
Metric Plug (M12X1),
DESINA
E† Explosion Proof
G‡^ Plug-In Conduit Box
J*† Deutsch (DT06-2S)
M*† Metri-Pack (150)
P DIN with Plug
S*#† Double Spade
W† DIN w/o Plug
# Not CSA approved.
Not available with lights.
* DC Only.
** No variations – See Plug-in.
Required for variations
on Conduit Box style.
^ Must have lights.
¤
Must have Diode Surge
Suppressor.
Code Description
Omit Standard Pressure
103.5 Bar (1500 PSI) AC
207 Bar (3000 PSI) DC
H* High Pressure, AC only
207 Bar (3000 PSI)
* Not available with CSA.
Code Description
Omit Standard Response,
No Switch
I3 Monitor Switch,
‘A’ & ‘B’ Port End
I6 Monitor Switch,
‘A’ & ‘B’ Port Start
Note: Not CE or CSA approved.
Spools 8, 9, 81 and 82 not available.
Code Description
Omit Standard
P Extended with Boot
T† None
DC or AC Rectified only.
Manual Override options not
available with Explosion Proof.
Ordering Information Series D31V (Design 91)
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
8
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Code Description
5*
Signal Lights – Standard
Signal Lights – Hirsch. (DIN with Plug)
7B** Manaplug – Brad Harrison (12x1) Micro with Lights
56** Manaplug (Mini) with Lights
20 Fast Response
1C** Manaplug (Mini) Single Sol. 5-pin, with Lights
1D** Manaplug (Micro) Single Sol. 5-pin, with Lights
1G** Manaplug (Mini) Single Sol. 5-pin,
with Stroke Adjust ‘A’ & ‘B’ End and Lights
1H** Manaplug (Micro) Single Sol. 5-pin,
with Stroke Adjust ‘A’ & ‘B’ End and Lights
1M Manaplug Opposite Normal
1P Painted Body
1R Stroke Adjust ‘A’ & ‘B’ End with Pilot Choke Meter In
3A Pilot Choke Meter Out
3B Pilot Choke Meter In
3C Pilot Pressure Reducer
3D Stroke Adjust ‘B’ End
3E Stroke Adjust ‘A’ End
3F Stroke Adjust ‘A’ & ‘B’ End
3G* Pilot Choke Meter Out with Lights
3H* Pilot Choke Meter In with Lights
3J* Pilot Pressure Reducer with Lights
3K Pilot Choke Meter Out
with Stroke Adjust ‘A’ & ‘B’ End
3L** Pilot Choke Meter Out, Stroke Adjust ‘A’ & ‘B’ End
with Lights and Manaplug — Brad Harrison Mini
3M Pilot Choke Meter Out, Pilot Pressure Reducer,
Stroke Adjust ‘A’ & ‘B’ End
3R Pilot Choke Meter Out & Pilot Pressure Reducer
3S** Lights, Mini Manaplug, Pilot Choke Meter Out
7Y** M12x1 Manaplug (4-pin), Special Wiring, and Lights
* DESINA, plug-in conduit box, and DIN with plug styles only.
** Must have plug-in style conduit box.
Valve Variations
Bold: Designates Tier I products and options.
Non-bold: Designates Tier II products and options. These products will have longer lead times.
Ordering Information Series D31V (Design 91)
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
9
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Technical Information Series D61V (Design 91)
Mounting Pattern NFPA D08
CETOP 8, NG25
Maximum Operating 207 Bar (3000 PSI) Standard
Pressure
CSA
205 Bar (3000 PSI)
Maximum Tank Line Internal Drain Model:
Pressure 102 Bar (1500 PSI) AC Only
205 Bar (3000 PSI) DC Std./
AC Optional
External Drain Model:
205 Bar (3000 PSI)
CSA
102 Bar (1500 PSI)
Maximum Drain 102 Bar (1500 PSI) AC Standard
Pressure 205 Bar (3000 PSI) DC Standard/
AC Optional
CSA
102 Bar (1500 PSI)
Minimum Pilot
Pressure 5.1 Bar* (75 PSI)
Maximum Pilot 205 Bar (3000 PSI) Standard
Pressure
CSA
205 Bar (3000 PSI)
Nominal Flow 189 LPM (50 GPM)
General Description
Series D61VW directional control valves are
5-chamber, pilot operated, solenoid controlled valves,
They are available in 2 or 3-position styles. These
valves are manifold or subplate mounted, and conform
to NFPA's D08, CETOP 8 mounting patterns.
Operation
Series D61VW pilot operated valves are standard with
low shock spools and pilot orifice. The orifice can be
removed if a faster shift is required. It is recom-
mended, however, that all systems operating above
138 Bar (2000 PSI) use the standard valve to avoid
severe shock.
Features
Low pressure drop design.
Hardened spools provide long life.
Fast response option available.
Explosion proof availability.
Wide variety of voltages and electrical connection
options.
No tools required for coil removal.
Specifications
* 6.9 Bar (100 PSI) for spool configurations 002, 007, 008, 009 & 014.
Response Time
Response times (milliseconds) are measured at
205 Bar (3000 PSI) and 195 LPM (50 GPM) with
various pilot pressures as indicated.
Solenoid Pilot
Pull-In Drop-Out
Type Pressure Std Fast Std Fast
500 130 100 80 80
DC 1000 90 90 80 80
2000 80 80 80 80
500 80 40 72 72
AC 1000 40 40 72 72
2000 30 30 72 72
Because of the high drain line pressure transients
generated during shifting, use of the fast response
option is not recommended for pilot pressures exceed-
ing 138 Bar (2000 PSI)
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
10
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
D
Directional
Control Valve
Basic Valve Actuator Spool Style
Seal
Solenoid
Voltage
Pilot Supply
and Drain
61V
NFPA D08, CETOP 8,
DIN NG25
Low Flow, D03 Pilot
Code Description
W* Solenoid, Wet Pin,
Screw-in
HW* Reversed Wiring
Code Description
A* 24/50 VAC
D 120 VDC
G 198 VDC
J 24 VDC
K 12 VDC
N** 220/50 VAC
Q* 100/60 VAC
R 24/60 VAC
T 240/60 - 220/50 VAC
U 98 VDC
Y 120/60 - 110/50 VAC
Z 250 VDC
* High Watt only.
** Explosion Proof only.
Code Description
N Nitrile
V Fluorocarbon
Code Description
1 Internal Pilot, External Drain
2 External Pilot, External Drain
3** Internal Pilot w/Check,
External Drain
4* Internal Pilot, Internal Drain
5 External Pilot, Internal Drain
6** Internal Pilot w/Check
Internal Drain
* Not availble with 002, 007,
008, 009 & 014 spools.
** #3 and #6 bodies cannot be
converted to other styles.
Other pilot versions cannot
be converted to styles
3 and 6.
Bold: Designates Tier I products and options.
Non-bold: Designates Tier II products and options. These products will have longer lead times.
Code Description Symbol
B* Single solenoid, 2 position, spring offset.
P to A and B to T in offset position.
C Double Solenoid, 3 position, spring centered.
D* Double solenoid, 2 position, detent.
E Single solenoid, 2 position, spring centered.
P to B and A to T when energized.
F** Single solenoid, 2 position, spring offset,
energized to center. Position spool spacer on
A side. P to A and B to T in spring offset position.
H* Single solenoid, 2 position, spring offset.
P to B and A to T in offset position.
K Single solenoid, 2 position, spring centered.
P to A and B to T when energized.
M** Single solenoid, 2 position, spring offset,
energized to center position. Spool spacer on
B side. P to B and A to T in spring offset position.
* Available with 001, 002, 004, 011 and 014 spools only.
** High watt coil only.
Code Symbol
001
002
003
004
005
006
007
008*
009**
Ordering Information Series D61V (Design 91)
AB
PT
b
AB
PT
ba
AB
PT
b
a
AB
PT
b
AB
PT
b
AB
PT
a
AB
PT
a
AB
PT
a
* Valve schematic symbols are
per NFPA/ANSI standards,
providing flow P to A when
energizing solenoid A. Note
operators reverse sides for
#008 and #009 spools. See
installation information for
details. To configure per DIN
standards (A coil over A port,
B coil over B port) code
valves as D1VHW***.
* 008 spool has closed crossover.
** 009 spool has open crossover.
Code Symbol
011
012
014
015
016
020*
021
022
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
11
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Valve Weight: Double Solenoid 12.1 kg (26.6 lbs.)
Standard Bolt Kit: BK227
Tube
Options
Approvals
Design
Series
NOTE:
Not required
when ordering.
Manual
Override
Options
Coil
Options
Electrical
Options
Shift
Response
and Indication
Valve
Variations
Code Description
Omit High Watt
D#
¤
Explosion Proof,
EEXD ATEX
E#
¤
Explosion Proof,
EEXME ATEX
F** Low Watt
L*** 8 Watt
O#
¤
Explosion Proof,
MSHA
U#
¤
Explosion Proof,
UL/CSA
X* No Coils
* See solenoid voltage code
to specify proper tube.
** AC only.
*** DC or AC Rectified only.
# Explosion Proof – coils
are 60 Hz at Std. voltage.
Dual rating not available.
¤
Lights, softshift, and other
options are not available
on Explosion Proof coils.
Code Description
Omit Standard Response,
No Switch
I3 Monitor Switch,
‘A’ & ‘B’ Port End
I6 Monitor Switch,
‘A’ & ‘B’ Port Start
Note: Not CE or CSA approved.
See next page
Code Description
Omit Standard Valve
3*† CSA USA (UL 429)
4* CSA Approved**
* Not available with AC high
pressure tube.
** Valve is derated with this
option.
B, C, H styles only. J, K, Y, U
voltages only with C, G, W
solenoid connections only.
Code Description
Omit No Options
J* Diode Surge
Suppressor
Z Rectified Coil
* DC or AC Rectified only.
DIN coil must include plug
with lights.
Bold: Designates Tier I products and options.
Non-bold: Designates Tier II products and options. These products will have longer lead times.
Solenoid
Connection
Code Description
C** Conduit Box
D*^
¤
Metric Plug (M12X1),
DESINA
E† Explosion Proof
G‡^ Plug-In Conduit Box
J*† Deutsch (DT06-2S)
M*† Metri-Pack (150)
P DIN with Plug
S*#† Double Spade
W† DIN w/o Plug
# Not CSA approved.
Not available with lights.
* DC Only.
** No variations – See Plug-in.
Required for variations
on Conduit Box style.
^ Must have lights.
¤
Must have Diode Surge
Suppressor.
Code Description
Omit Standard Pressure
103.5 Bar (1500 PSI) AC
207 Bar (3000 PSI) DC
H* High Pressure, AC only
207 Bar (3000 PSI)
* Not available with CSA.
Code Description
Omit Standard
P Extended with Boot
T† None
DC or AC Rectified only.
Manual Override options not
available with Explosion Proof.
Ordering Information Series D61V (Design 91)
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
12
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Ordering Information Series D61V (Design 91)
Code Description
5*
Signal Lights – Standard
Signal Lights – Hirsch. (DIN with plug)
7B** Manaplug – Brad Harrison (12x1) Micro with lights
56** Manaplug (Mini) with Lights
20 Fast Response
1C** Manaplug (Mini) Single Sol. 5-pin, with Lights
1D** Manaplug (Micro) Single Sol. 5-pin, with Lights
1G** Manaplug (Mini) Single Sol. 5-pin,
with Stroke Adjust ‘A’ & ‘B’ End and Lights
1H** Manaplug (Micro) Single Sol. 5-pin,
with Stroke Adjust ‘A’ & ‘B’ End and Lights
1M Manaplug Opposite Normal
1P Painted Body
1R Stroke Adjust ‘A’ & ‘B’ End with Pilot Choke Meter In
3A Pilot Choke Meter Out
3B Pilot Choke Meter In
3C Pilot Pressure Reducer
3D Stroke Adjust ‘B’ End
3E Stroke Adjust ‘A’ End
3F Stroke Adjust ‘A’ & ‘B’ End
3G* Pilot Choke Meter Out with Lights
3H* Pilot Choke Meter In with Lights
3J* Pilot Pressure Reducer with Lights
3K Pilot Choke Meter Out
with Stroke Adjust ‘A’ & ‘B’ End
3L** Pilot Choke Meter Out, Stroke Adjust ‘A’ & ‘B’ End
with Lights and Manaplug — Brad Harrison Mini
3M Pilot Choke Meter Out, Pilot Pressure Reducer,
Stroke Adjust ‘A’ & ‘B’ End
3R Pilot Choke Meter Out & Pilot Pressure Reducer
3S** Lights, Mini Manaplug, Pilot Choke Meter Out
7Y** M12x1 Manaplug (4-pin), Special Wiring, and Lights
* DESINA, plug-in conduit box, and DIN with plug styles only.
** Must have plug-in style conduit box.
Valve Variations
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
13
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Technical Information Series D81V (Design 91)
General Description
Series D81VW directional control valves are
5-chamber, pilot operated, solenoid controlled valves.
They are available in 2 or 3-position styles. These
valves are manifold or subplate mounted, and conform
to NFPA's D08, CETOP 8 mounting pattern.
Operation
Series D81VW pilot operated valves are standard with
low shock spools and pilot orifice. The orifice can be
removed if a faster shift is required. It is recommended,
however, that all systems operating above 138 Bar
(2000 PSI) use the standard valve to avoid severe
shock.
Features
Low pressure drop design.
Hardened spools provide long life.
Fast response option available.
Wide variety of voltages and electrical connection options.
Explosion proof availability.
No tools required for coil removal.
Response Time
Response times (milliseconds) are measured at
345 Bar (5000 PSI) and 300 LPM (80 GPM) with
various pilot pressures as indicated.
Because of the high drain line pressure transients
generated during shifting, use of the fast response
option is not recommended for pilot pressures exceed-
ing 205 Bar (2000 PSI)
Solenoid Pilot
Pull-In Drop-Out
Type Pressure Std Fast Std Fast
500 140 100 70 70
DC 1000 125 90 76 76
2000 100 70 70 70
500 100 60 60 60
AC 1000 85 50 60 60
2000 60 30 60 60
Bolt Kits
For use with 3/4" Manapaks and D8 Series Directional
Control Valves. All bolts are SAE grade 8, 1/2 -13 UNC-13A.
2.75 Thick Manapaks
(New Style) Bolt Kit
0 BK228
1 BK131
2 BK132
Pilot Valve with 1 Manapak:
BK400 (M5 x 70 Metric Bolt)
Mounting Pattern NFPA D08,
CETOP 8, NG25
Maximum Operating 350 Bar (5000 PSI) Standard
Pressure 207 Bar (3000 PSI) DC Low Watt
CSA
207 Bar (3000 PSI)
Maximum Tank Line Internal Drain Model:
Pressure 102 Bar (1500 PSI) AC Only
205 Bar (3000 PSI) DC Std.,
AC Optional
External Drain Model:
350 Bar (5000 PSI)
CSA 102 Bar (1500 PSI)
Maximum Drain 102 Bar (1500 PSI) AC Only
Pressure 205 Bar (3000 PSI) DC Std.,
AC Optional
CSA
102 Bar (1500 PSI)
Minimum Pilot 5.1 Bar* (75 PSI)
Pressure
Maximum Pilot 350 Bar (5000 PSI) Standard
Pressure 207 Bar (3000 PSI) DC Low Watt
CSA
207 Bar (3000 PSI)
Nominal Flow 302 LPM (80 GPM)
Specifications
* 6.9 Bar (100 PSI) for spool configurations 002, 007,008, 009 & 014.
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
14
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
D
Directional
Control Valve
Basic Valve Actuator Spool Style
Seal
Solenoid
Voltage
Pilot Supply
and Drain
NFPA D08, CETOP 8,
DIN NG25
High Flow, D03 Pilot
81V
Code Description
W* Solenoid, Wet Pin,
Screw-in
HW* Reversed Wiring
Code Description
A* 24/50 VAC
D 120 VDC
G 198 VDC
J 24 VDC
K 12 VDC
N** 220/50 VAC
Q* 100/60 VAC
R 24/60 VAC
T 240/60 - 220/50 VAC
U 98 VDC
Y 120/60 - 110/50 VAC
Z 250 VDC
* High Watt Coil only.
** Explosion Proof only.
Code Description
N Nitrile
V Fluorocarbon
Bold: Designates Tier I products and options.
Non-bold: Designates Tier II products and options. These products will have longer lead times.
Code Symbol
001
002
003
004
005
006
007
008*
009**
011
Code Symbol
012
014
015
016
020*
030**
081
082
* 008 & 020 spool have closed crossover.
** 009 & 030 spool have open crossover.
Code Description Symbol
B* Single solenoid, 2 position, spring offset.
P to A and B to T in offset position.
C Double Solenoid, 3 position, spring centered.
D* Double solenoid, 2 position, detent.
E Single solenoid, 2 position, spring centered.
P to B and A to T when energized.
F** Single solenoid, 2 position, spring offset,
energized to center. Position spool spacer on
A side. P to A and B to T in spring offset position.
H* Single solenoid, 2 position, spring offset.
P to B and A to T in offset position.
K Single solenoid, 2 position, spring centered.
P to A and B to T when energized.
M** Single solenoid, 2 position, spring offset,
energized to center position. Spool spacer on
B side. P to B and A to T in spring offset position.
* Is available with 020 and 030 spools only.
** High watt coil only.
Code Description
1 Internal Pilot,
External Drain
2 External Pilot,
External Drain
3 Internal Pilot w/Check,
External Drain
4* Internal Pilot,
Internal Drain
5 External Pilot,
Internal Drain
6 Internal Pilot w/Check,
Internal Drain
* Not availble with 002, 007,
008, 009, 014 & 030 spools.
Ordering Information Series D81V (Design 91)
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
b
AB
PT
ba
AB
PT
b
a
AB
PT
b
AB
PT
b
AB
PT
a
AB
PT
a
AB
PT
a
* Valve schematic symbols are per NFPA/
ANSI standards, providing flow P to A
when energizing solenoid A. Note
operators reverse sides for #008 and
#009 spools. See installation information
for details. To configure per DIN
standards (A coil over A port, B coil over
B port) code valves as D1VHW***.
AB
PT
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
15
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Valve Weight: Double Solenoid 19.6 kg (43.2 lbs.)
Standard Bolt Kit: BK228
Tube
Options
Approvals
Design
Series
NOTE:
Not required
when ordering.
Manual
Override
Options
Coil
Options
Electrical
Options
Shift
Response
and Indication
Valve
Variations
* DC or AC Rectified only.
DIN coil must include plug
with lights.
Bold: Designates Tier I products and options.
Non-bold: Designates Tier II products and options. These products will have longer lead times.
Solenoid
Connection
Code Description
C** Conduit Box
D*^
¤
Metric Plug (M12X1),
DESINA
E† Explosion Proof
G‡^ Plug-In Conduit Box
J*† Deutsch (DT06-25)
M*† Metri-Pack (150)
P DIN with Plug
S*#† Double Spade
W† DIN w/o Plug
# Not CSA approved.
Not available with lights.
* DC Only.
** No variations – See Plug-in.
Required for variations
on Conduit Box style.
^ Must have lights.
¤
Must have Diode Surge
Suppressor.
See next page
Code Description
Omit Standard Valve
3*† CSA USA (UL 429)
4* CSA Approved**
* Not available with AC high
pressure tube.
** Valve is derated with this
option.
B, C, H styles only. J, K, Y, U
voltages only with C, G, W
solenoid connections only.
Code Description
Omit Standard Response,
No Switch
I3 Monitor Switch,
‘A’ & ‘B’ Port End
I6 Monitor Switch,
‘A’ & ‘B Port Start
Note: Not CE or CSA approved.
Not available with ‘F’ or ‘M’ styles.
Ordering Information Series D81V (Design 91)
Code Description
Omit Standard
P Extended
with Boot
T† None
DC or AC Rectified only.
Manual Override options
not available with Explosion
Proof.
Code Description
Omit High Watt
D#
¤
Explosion Proof,
EEXD ATEX
E#
¤
Explosion Proof,
EEXME ATEX
F** Low Watt
L*** 8 Watt
O#
¤
Explosion Proof,
MSHA
U#
¤
Explosion Proof,
UL/CSA
X* No Coils
* See solenoid voltage code
to specify proper tube.
** AC only.
*** DC or AC Rectified only.
# Explosion Proof – coils are
60 Hz at Std. voltage.
Dual rating not available.
¤
Lights, softshift, and other
options are not available
on Explosion Proof coils.
Code Description
Omit Standard Pressure
103.5 Bar (1500 PSI) AC
207 Bar (3000 PSI) DC
H* High Pressure, AC only
207 Bar (3000 PSI)
* Not available with CSA.
Code Description
Omit No Options
J* Diode Surge
Suppressor
Z Rectified Coil
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
16
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Ordering Information Series D81V (Design 91)
Code Description
5*
Signal Lights – Standard
Signal Lights – Hirsch. (DIN with plug)
7B** Manaplug – Brad Harrison (12x1) Micro with Lights
56** Manaplug (Mini) with Lights
20 Fast Response
1C** Manaplug (Mini) Single Sol. 5-pin, with Lights
1D** Manaplug (Micro) Single Sol. 5-pin, with Lights
1G** Manaplug (Mini) Single Sol. 5-pin,
with Stroke Adjust ‘A’ & ‘B’ End and Lights
1H** Manaplug (Micro) Single Sol. 5-pin,
with Stroke Adjust ‘A’ & ‘B’ End and Lights
1M Manaplug Opposite Normal
1P Painted Body
1R Stroke Adjust ‘A’ & ‘B’ End with Pilot Choke Meter In
3A Pilot Choke Meter Out
3B Pilot Choke Meter In
3C Pilot Pressure Reducer
3D Stroke Adjust ‘B’ End
3E Stroke Adjust ‘A’ End
3F Stroke Adjust ‘A’ & ‘B’ End
3G* Pilot Choke Meter Out with Lights
3H* Pilot Choke Meter In with Lights
3J* Pilot Pressure Reducer with Lights
3K Pilot Choke Meter Out
with Stroke Adjust ‘A’ & ‘B’ End
3L** Pilot Choke Meter Out, Stroke Adjust ‘A’ & ‘B’ End
with Lights and Manaplug — Brad Harrison Mini
3M Pilot Choke Meter Out, Pilot Pressure Reducer,
Stroke Adjust ‘A’ & ‘B’ End
3R Pilot Choke Meter Out and Pilot Pressure Reducer
3S** Lights, Mini Manaplug, Pilot Choke Meter Out
7Y** M12x1 Manaplug (4-pin), Special Wiring, and Lights
* DESINA, plug-in conduit box, and DIN with plug styles only.
** Must have plug-in style conduit box.
Valve Variations
Bold: Designates Tier I products and options.
Non-bold: Designates Tier II products and options. These products will have longer lead times.
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
17
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Technical Information Series D101V (Design 91)
Mounting Pattern NFPA D10 , CETOP 10,
NG32
Maximum Operating
Pressure 207 Bar (3000 PSI) Standard
CSA
207 Bar (3000 PSI)
Maximum Tank Line
Pressure Internal Drain Model:
102 Bar (1500 PSI) AC Only
207 Bar (3000 PSI)
DC Standard/AC Optional
External Drain Model:
207 Bar (3000 PSI)
CSA 102 Bar (1500 PSI)
Maximum Drain 102 Bar (1500 PSI) AC Only
Pressure 207 Bar (3000 PSI)
DC Standard/AC Optional
CSA
102 Bar (1500 PSI)
Minimum Pilot 4.4 Bar (65 PSI)
Pressure
Maximum Pilot
Pressure 207 Bar (3000 PSI) Standard
CSA
207 Bar (3000 PSI)
Nominal Flow 378 LPM (100 GPM)
General Description
Series D101VW directional control valves are
5-chamber, pilot operated, solenoid controlled valves.
They are available in 2 or 3-position styles. These
valves are manifold or subplate mounted, and conform
to NFPA's D10, CETOP 10 mounting pattern.
Operation
Series D101VW pilot operated valves are standard
with low shock spools and pilot orifice. The orifice can
be removed if a faster shift is required. However, it is
recommended that all systems operating above
138 Bar (2000 PSI) use the standard valve to avoid
severe shock.
Features
Low pressure drop design
Hardened spools provide long life
Fast response option available
Wide variety of voltags and electrical connection options
Explosion proof availability
No tools required for coil removal
Specifications
Response Time
Response times (milliseconds) are measured at
205 Bar (3000 PSI) and 416 LPM (110 GPM) with
various pilot pressures as indicated.
Solenoid Pilot
Pull-In Drop-Out
Type Pressure Std Fast Std Fast
500 180 170 195 195
DC 1000 130 125 195 195
2000 100 95 195 195
500 140 130 185 185
AC 1000 90 85 185 185
2000 60 55 185 185
Because of the high drain line pressure transients
generated during shifting, use of the fast response
option is not recommended for pilot pressures
exceeding 205 Bar (2000 PSI).
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
18
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Bold: Designates Tier I products and options.
Non-bold: Designates Tier II products and options. These products will have longer lead times.
Ordering Information Series D101V (Design 91)
D
Directional
Control Valve
Basic Valve Actuator Spool Style
Seal
Solenoid
Voltage
Pilot Supply
and Drain
101V
Code Description
W* Solenoid, Wet Pin,
Screw-in
HW* Reversed Wiring
Code Description
N Nitrile
V Fluorocarbon
NFPA D10
CETOP 10
DIN NG32
D03 Pilot
Code Description
1 Internal Pilot,
External Drain
2 External Pilot,
External Drain
3 Internal Pilot w/Check,
External Drain
4# Internal Pilot,
Internal Drain
5 External Pilot,
Internal Drain
6 Internal Pilot w/Check,
Internal Drain
# Not available with 002, 007,
008 and 009 spools.
Code Description
A* 24/50 VAC
D 120 VDC
G 198 VDC
J 24 VDC
K 12 VDC
N** 220/50 VAC
Q* 100/60 VAC
R 24/60 VAC
T 240/60 - 220/50 VAC
U 98 VDC
Y 120/60 - 110/50 VAC
Z 250 VDC
* High Watt only.
** Explosion Proof only.
Code Description Symbol
B* Single solenoid, 2 position, spring offset.
P to A and B to T in offset position.
C Double Solenoid, 3 position, spring centered.
D* Double solenoid, 2 position, detent.
E Single solenoid, 2 position, spring centered.
P to B and A to T when energized.
F Single solenoid, 2 position, spring offset,
energized to center. Position spool spacer on
A side. P to A and B to T in spring offset position.
H* Single solenoid, 2 position, spring offset.
P to B and A to T in offset position.
K Single solenoid, 2 position, spring centered.
P to A and B to T when energized.
M Single solenoid, 2 position, spring offset,
energized to center position. Spool spacer on
B side. P to B and A to T in spring offset position.
* Is available with 001, 002, 004 and 011 spools only.
AB
PT
b
AB
PT
ba
AB
PT
b
a
AB
PT
b
AB
PT
b
AB
PT
a
AB
PT
a
AB
PT
a
* Valve schematic symbols are per NFPA/
ANSI standards, providing flow P to A
when energizing solenoid A. Note
operators reverse sides for #008 and
#009 spools. See installation information
for details. To configure per DIN
standards (A coil over A port, B coil over
B port) code valves as D1VHW***.
Code Symbol
001
002
003
004
005
* 008 spool has closed crossover.
** 009 spool has open crossover.
Code Symbol
006
007
008*
009**
011
012
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
AB
PT
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
19
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Tube
Options
Approvals
Design
Series
NOTE:
Not required
when ordering.
Manual
Override
Options
Electrical
Options
Shift
Response
and Indication
Valve
Variations
Code Description
Omit Standard Response,
No Switch
I3 Monitor Switch,
‘A’ & ‘B’ Port End
I6 Monitor Switch,
‘A’ & ‘B’ Port Start
Note: Not CE or CSA approved.
Not available with ‘F’ or ‘M’ styles.
Valve Weight: Double Solenoid 35.0 kg (77.1 lbs.)
Standard Bolt Kit: BK229
Code Description
Omit Standard Valve
3*† CSA USA (UL 429)
4* CSA Approved
* Not available with AC high
pressure tube.
B, C, H styles only. J, K, Y, U
voltages only with C, G, W
solenoid connections only.
Code Description
Omit No Options
J* Diode Surge
Suppressor
Z Rectified Coil
* DC or AC Rectified only.
DIN coil must include plug
with lights.
Bold: Designates Tier I products and options.
Non-bold: Designates Tier II products and options. These products will have longer lead times.
Code Description
C** Conduit Box
D*^
¤
Metric Plug (M12X1),
DESINA
E† Explosion Proof
G‡^ Plug-In Conduit Box
J*† Deutsch (DT06-25)
M*† Metri-Pack (150)
P DIN with Plug
S*#† Double Spade
W† DIN w/o Plug
# Not CSA approved.
Not available with lights.
* DC Only.
** No variations – See Plug-in.
Required for variations
on Conduit Box style.
^ Must have lights.
¤
Must have Diode Surge
Suppressor.
See next page
Solenoid
Connection
Code Description
Omit Standard
P Extended
with Boot
T* None
* DC or AC Rectified only.
Manual Override options
not available with
Explosion Proof.
Code Description
Omit Standard Pressure
103.5 Bar (1500 PSI) AC
207 Bar (3000 PSI) DC
H* High Pressure, AC only
207 Bar (3000 PSI)
* Not available with CSA.
Code Description
Omit High Watt
D#
¤
Explosion Proof,
EEXD ATEX
E#
¤
Explosion Proof,
EEXME ATEX
F** Low Watt
L*** 8 Watt
O#
¤
Explosion Proof,
MSHA
U#
¤
Explosion Proof,
UL/CSA
X* No Coils
* See solenoid voltage code
to specify proper tube.
** AC only.
*** DC or AC Rectified only.
# Explosion Proof – coils
are 60 Hz at Std. voltage.
Dual rating not available.
¤
Lights, softshift, and other
options are not available
on Explosion Proof coils.
Coil
Options
Ordering Information Series D101V (Design 91)
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
20
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Ordering Information Series D101V (Design 91)
Bold: Designates Tier I products and options.
Non-bold: Designates Tier II products and options. These products will have longer lead times.
Code Description
5*
Signal Lights – Standard
Signal Lights – Hirsch. (DIN with plug)
7B** Manaplug – Brad Harrison (12x1) Micro with Lights
56** Manaplug (Mini) with Lights
20 Fast Response
1C** Manaplug (Mini) Single Sol. 5-pin, with Lights
1D** Manaplug (Micro) Single Sol. 5-pin, with Lights
1G** Manaplug (Mini) Single Sol. 5-pin,
with Stroke Adjust ‘A’ & ‘B’ End and Lights
1H** Manaplug (Micro) Single Sol. 5-pin,
with Stroke Adjust ‘A’ & ‘B’ End and Lights
1M Manaplug Opposite Normal
1P Painted Body
1R Stroke Adjust ‘A’ & ‘B’ End with Pilot Choke Meter In
3A Pilot Choke Meter Out
3B Pilot Choke Meter In
3C Pilot Pressure Reducer
3D Stroke Adjust ‘B’ End
3E Stroke Adjust ‘A’ End
3F Stroke Adjust ‘A’ & ‘B’ End
3G* Pilot Choke Meter Out with Lights
3H* Pilot Choke Meter In with Lights
3J* Pilot Pressure Reducer with Lights
3K Pilot Choke Meter Out
with Stroke Adjust ‘A’ & ‘B’ End
3L** Pilot Choke Meter Out, Stroke Adjust ‘A’ & ‘B’ End
with Lights and Manaplug — Brad Harrison Mini
3M Pilot Choke Meter Out, Pilot Pressure Reducer,
Stroke Adjust ‘A’ & ‘B’ End
3R Pilot Choke Meter Out and Pilot Pressure Reducer
3S** Lights, Mini Manaplug, Pilot Choke Meter Out
7Y** M12x1 Manaplug (4-pin), Special Wiring, and Lights
* DESINA, plug-in conduit box, and DIN with plug styles only.
** Must have plug-in style conduit box.
Valve VariationsValve Variations
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
21
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Terms of Sale with Warranty Limitations
Offer of Sale
The items described in this document and other documents or descriptions provided by Parker Hannifin Corporation, its subsidiaries and its authorized
distributors are hereby offered for sale at prices to be established by Parker Hannifin Corporation, its subsidiaries and its authorized distributors. This
offer and its acceptance by any customer ("Buyer") shall be governed by all of the following Terms and Conditions. Buyer’s order for any such items,
when communicated to Parker Hannifin Corporation, its subsidiary or an authorized distributor ("Seller") verbally or in writing, shall constitute acceptance
of this offer.
verted or adapted for such manufacture and notwithstanding any charges
paid by Buyer. Unless otherwise agreed, Seller shall have the right to alter,
discard or otherwise dispose of any special tooling or other property in its
sole discretion at any time.
8. Buyer’s Property: Any designs, tools, patterns, materials, drawings,
confidential information or equipment furnished by Buyer or any other
items which become Buyer’s property, may be considered obsolete and
may be destroyed by Seller after two (2) consecutive years have elapsed
without Buyer placing an order for the items which are manufactured using
such property, Seller shall not be responsible for any loss or damage to
such property while it is in Seller’s possession or control.
9. Taxes: Unless otherwise indicated on the face hereof, all prices and
charges are exclusive of excise, sales, use, property, occupational or like
taxes which may be imposed by any taxing authority upon the manufac-
ture, sale or delivery of the items sold hereunder. If any such taxes must
be paid by Seller or if Seller is liable for the collection of such tax, the
amount thereof shall be in addition to the amounts for the items sold. Buyer
agrees to pay all such taxes or to reimburse Seller therefore upon receipt
of its invoice. If Buyer claims exemption from any sales, use or other tax
imposed by any taxing authority, Buyer shall save Seller harmless from
and against any such tax, together with any interest or penalties thereon
which may be assessed if the items are held to be taxable.
10. Indemnity For Infringement of Intellectual Property Rights: Seller
shall have no liability for infringement of any patents, trademarks, copy-
rights, trade dress, trade secrets or similar rights except as provided in this
Part 10. Seller will defend and indemnify Buyer against allegations of
infringement of U.S. Patents, U.S. Trademarks, copyrights, trade dress
and trade secrets (hereinafter ‘Intellectual Property Rights’). Seller will
defend at its expense and will pay the cost of any settlement or damages
awarded in an action brought against Buyer based on an allegation that
an item sold pursuant to this contract infringes the Intellectual Property
Rights of a third party. Seller’s obligation to defend and indemnify Buyer
is contingent on Buyer notifying Seller within ten (10) days after Buyer
becomes aware of such allegations of infringement, and Seller having sole
control over the defense of any allegations or actions including all
negotiations for settlement or compromise. If an item sold hereunder is
subject to a claim that it infringes the Intellectual Property Rights of a third
party, Seller may, at its sole expense and option, procure for Buyer the
right to continue using said item, replace or modify said item so as to make
it noninfringing, or offer to accept return of said item and return the
purchase price less a reasonable allowance for depreciation. Notwith-
standing the foregoing, Seller shall have no liability for claims of infringe-
ment based on information provided by Buyer, or directed to items
delivered hereunder for which the designs are specified in whole or part
by Buyer, or infringements resulting from the modification, combination or
use in a system of any item sold hereunder. The foregoing provisions of
this Part 10 shall constitute Seller’s sole and exclusive liability and Buyer’s
sole and exclusive remedy for infringement of Intellectual Property Rights.
If a claim is based on information provided by Buyer or if the design for an
item delivered hereunder is specified in whole or in part by Buyer, Buyer
shall defend and indemnify Seller for all costs, expenses or judgments
resulting from any claim that such item infringes any patent, trademark,
copyright, trade dress, trade secret or any similar right.
11. Force Majeure: Seller does not assume the risk of and shall not be
liable for delay or failure to perform any of Seller’s obligations by reason
of circumstances beyond the reasonable control of Seller (hereinafter
‘Events of Force Majeure’). Events of Force Majeure shall include without
limitation, accidents, acts of God, strikes or labor disputes, acts, laws,
rules or regulations of any government or government agency, fires,
floods, delays or failures in delivery of carriers or suppliers, shortages of
materials and any other cause beyond Seller’s control.
12. Entire Agreement/Governing Law: The terms and conditions set
forth herein, together with any amendments, modifications and any
different terms or conditions expressly accepted by Seller in writing, shall
constitute the entire Agreement concerning the items sold, and there are
no oral or other representations or agreements which pertain thereto. This
Agreement shall be governed in all respects by the law of the State of Ohio.
No actions arising out of the sale of the items sold hereunder or this
Agreement may be brought by either party more than two (2) years after
the cause of action accrues. 9/91-P
1. Terms and Conditions of Sale: All descriptions, quotations, propos-
als, offers, acknowledgments, acceptances and sales of Seller’s products
are subject to and shall be governed exclusively by the terms and
conditions stated herein. Buyer’s acceptance of any offer to sell is limited
to these terms and conditions. Any terms or conditions in addition to, or
inconsistent with those stated herein, proposed by Buyer in any accep-
tance of an offer by Seller, are hereby objected to. No such additional,
different or inconsistent terms and conditions shall become part of the
contract between Buyer and Seller unless expressly accepted in writing by
Seller. Seller’s acceptance of any offer to purchase by Buyer is expressly
conditional upon Buyer’s assent to all the terms and conditions stated
herein, including any terms in addition to, or inconsistent with those
contained in Buyer’s offer, Acceptance of Seller’s products shall in all
events constitute such assent.
2. Payment: Payment shall be made by Buyer net 30 days from the date
of delivery of the items purchased hereunder. Amounts not timely paid
shall bear interest at the maximum rate permitted by law for each month
or portion thereof that the Buyer is late in making payment. Any claims by
Buyer for omissions or shortages in a shipment shall be waived unless
Seller receives notice thereof within 30 days after Buyer’s receipt of the
shipment.
3. Delivery: Unless otherwise provided on the face hereof, delivery shall
be made F.O.B. Seller’s plant. Regardless of the method of delivery,
however, risk of loss shall pass to Buyer upon Seller’s delivery to a carrier.
Any delivery dates shown are approximate only and Seller shall have no
liability for any delays in delivery.
4. Warranty: Seller warrants that the items sold hereunder shall be free
from defects in material or workmanship for a period of 18 months from
date of shipment from Parker Hannifin Corporation. THIS WARRANTY
COMPRISES THE SOLE AND ENTIRE WARRANTY PERTAINING TO
ITEMS PROVIDED HEREUNDER. SELLER MAKES NO OTHER WAR-
RANTY, GUARANTEE, OR REPRESENTATION OF ANY KIND WHAT-
SOEVER. ALL OTHER WARRANTIES, INCLUDING BUT NOT LIM-
ITED TO, MERCHANTABILITY AND FITNESS FOR PURPOSE,
WHETHER EXPRESS, IMPLIED, OR ARISING BY OPERATION OF
LAW, TRADE USAGE, OR COURSE OF DEALING ARE HEREBY
DISCLAIMED. NOTWITHSTANDING THE FOREGOING, THERE ARE
NO WARRANTIES WHATSOEVER ON ITEMS BUILT OR ACQUIRED
WHOLLY OR PARTIALLY, TO BUYER’S DESIGNS OR SPECIFICA-
TIONS.
5. Limitation Of Remedy: SELLER’S LIABILITY ARISING FROM OR IN
ANY WAY CONNECTED WITH THE ITEMS SOLD OR THIS CON-
TRACT SHALL BE LIMITED EXCLUSIVELY TO REPAIR OR RE-
PLACEMENT OF THE ITEMS SOLD OR REFUND OF THE PURCHASE
PRICE PAID BY BUYER, AT SELLER’S SOLE OPTION. IN NO EVENT
SHALL SELLER BE LIABLE FOR ANY INCIDENTAL, CONSEQUEN-
TIAL OR SPECIAL DAMAGES OF ANY KIND OR NATURE WHATSO-
EVER, INCLUDING BUT NOT LIMITED TO LOST PROFITS ARISING
FROM OR IN ANY WAY CONNECTED WITH THIS AGREEMENT OR
ITEMS SOLD HEREUNDER, WHETHER ALLEGED TO ARISE FROM
BREACH OF CONTRACT, EXPRESS OR IMPLIED WARRANTY, OR IN
TORT, INCLUDING WITHOUT LIMITATION, NEGLIGENCE, FAILURE
TO WARN OR STRICT LIABILITY.
6. Changes, Reschedules and Cancellations: Buyer may request to
modify the designs or specifications for the items sold hereunder as well
as the quantities and delivery dates thereof, or may request to cancel all
or part of this order, however, no such requested modification or cancel-
lation shall become part of the contract between Buyer and Seller unless
accepted by Seller in a written amendment to this Agreement. Acceptance
of any such requested modification or cancellation shall be at Seller’s
discretion, and shall be upon such terms and conditions as Seller may
require.
7. Special Tooling: A tooling charge may be imposed for any special
tooling, including without limitation, dies, fixtures, molds and patterns,
acquired to manufacture items sold pursuant to this contract. Such special
tooling shall be and remain Seller’s property notwithstanding payment of
any charges by Buyer. In no event will Buyer acquire any interest in
apparatus belonging to Seller which is utilized in the manufacture of the
items sold hereunder, even if such apparatus has been specially con-
SG HY14-1000, 2/12/07
Parker Safety Guide for Selecting and Using Hydraulic Valves and Related Accessories
WARNING: Failure or improper selection or improper use of Parker Hydraulic Valve Division (HVD) Valves or related accessories (“Products”) can
cause death, personal injury and property damage. Possible consequences of failure or improper use of these Products include but are not limited to:
Valves or parts thereof thrown off at high speed Contact with fluid that may be hot, cold, toxic or otherwise injurious
High velocity fluid discharge Injuries resulting from injection, inhalation or exposure to fluids
Explosion or burning of the conveyed fluid Injury from handling a heavy item (dropped, awkward lift)
Contact with suddenly moving or falling objects controlled by the Valve Electric shock from improper handling of solenoid connections
Injections by high-pressure fluid discharge Injury from slip or fall on spilled or leaked fluid
Before selecting or using any of these Products, it is important that you read and follow the instructions below. In general, the Products are not approved
for in-flight aerospace applications. Consult the factory for the few that are FAA approved.
1.-1 GENERAL INSTRUCTIONS
1.1 Scope: This safety guide provides instructions for selecting and using (including assembling, installing and maintaining) these Products. For convenience all items in
this guide are called “Valves”. This safety guide is a supplement to and is to be used in conjunction with the specific Parker catalogs for the specific Valves and/or
accessories being considered for use. See item 1.6 below for obtaining those catalogs.
1.2 Fail-Safe: Valves can and do fail without warning for many reasons. Design all systems and equipment in a fail-safe mode, so that failure of the Valve or Valve
Assembly will not endanger persons or property.
1.3 Safety Devices: Never disconnect, override, circumvent or otherwise disable any safety lockout on any system whether powered by HVD Valves or any motion
control system of any manufacturer. (e.g. Automatic shut-off on a riding lawn mower should the operator get out of the seat).
1.4 Distribution: Provide a copy of this safety guide to each person that is responsible for selecting or using HVD Valve Products. Do not select HVD Valves without
thoroughly reading and understanding this safety guide as well as the specific Parker catalogs for the Products considered or selected.
1.5 User Responsibility: Due the wide variety of operating conditions and applications for Valves, HVD and its distributors do not represent or warrant that any
particular Valve is suitable for any specific system. This safety guide does not analyze all technical parameters that must be considered in selecting a product. The
user, through its own analysis and testing is solely responsible for:
Making the final selection of the Valve
Assuring that the user’s requirements are met and that the application presents no health or safety hazards.
Providing all appropriate health and safety warnings on the equipment on which the Valves are used.
Assuring compliance with all applicable government and industry standards.
1.6 Additional Questions: Call the appropriate Parker technical service department if you have any questions or require any additional information. See the Parker
publication for the product being considered or used, or call 1-800-CPARKER, or go to www.parker.com , for the telephone numbers of the appropriate technical
service department. For additional copies of this or any other Parker Safety Guide go to www.parker.com and click on the safety button on the opening page. Catalogs
and/or catalog numbers for the various HVD Valve Products can be obtained by calling HVD at 440-366-5100. Phone numbers and catalog information is also
available on the Parker website, www.parker.com .
2.0 VALVE SELECTION INSTRUCTIONS
2.1 Pressure: Valve selection must be made so that the maximum working pressure of the Valve is equal to or greater than the maximum system pressure. Surge, impulse
or peak transient pressures in the system must be below the maximum working pressure of the Valve. Surge, impulse and peak pressures can usually be determined by
sensitive electrical instrumentation that measures and indicates pressures at millisecond intervals. Mechanical pressure gauges indicate only average pressure and
cannot be used to determine surge, impulse or peak transient pressures. Burst pressure ratings if given or known are for manufacturing purposes only and are not an
indication that the Product can be used in applications at the burst pressure or otherwise above the maximum working pressure.
2.2 Temperature: The fluid temperature must be regulated or controlled so that the operating viscosity of the fluid is maintained at a level specified for the particular
Valve product. Such ranges are given in the product catalogs or can be obtained from the appropriate customer service department for the particular Valve product.
2.3 Fluid Compatibility: The fluid conveyed in Valves has direct implications on the Valve selection. The fluid must be chemically compatible with the Valve
component materials. Elastomer seals, brass, cast iron, aluminum for example all are potentially affected by certain fluids. Additionally, fluid selection affects the
performance of various Valves. Considerations relative to fluid selection are outlined in the specific HVD Valve product catalog. Of particular importance is that the
fluid be for hydraulic use, contain the proper additives and wear inhibitors. See 1.6 “Additional Questions” above for information to obtain such HVD catalogs.
2.4 Changing Fluids: If a system requires a different fluid, it should be done with the guidance in number 2.3 above. Additionally, it may be necessary to flush the
system (including the Valves) to remove any of the previous fluid. Consult the Parker Valve Division for guidance.
2.5 Size: Transmission of power by means of pressurized fluid varies with pressure and rate of flow. The size of the components must be adequate to keep pressure losses
to a minimum and avoid damage due to heat generation or excessive fluid velocity.
2.6 Placement: Installation of Valves must take into account the orientation of the Valve and the proximity of the Valve to other parts of the system. This includes but is
not limited to closeness to hot and cold areas, access for servicing and operation as well as orientation for proper connectors.
2.7 Ports: Connection of Valves in systems can be by threaded ports, sub-base surfaces, flanges and manifolds. In all cases, the proper fitting, surface or mounting
hardware must be selected to properly seal and contain the system fluid so as to avoid the adverse conditions listed in the initial warning box above. Specifically, if
using threaded ports, the designer must make sure that the mating fitting is of the compatible thread. Also, the instructions provided by the connector hardware
supplier must be read and understood so as to properly assemble the connector. The Parker Safety Guide for using Hose, Tubing and Fittings and Related Accessories
is but one reference to this end.
2.8 Environment: Care must be taken to insure that the Valve and Valve Assemblies are either compatible with or protected from the environment (that is, surrounding
conditions) to which they are exposed. Environmental conditions including but not limited to ultraviolet radiation, sunlight, heat, ozone, moisture, water, salt water,
chemicals and air pollutants can cause degradation and premature failure.
2.9 Electric Power: For Valves requiring electric power for control, it is imperative that the electricity be delivered at the proper voltage, current and wattage
requirements. To obtain the proper control requirements please refer to the respective Parker product catalog for the specific Valve that is intended for use. If further
guidance is required, call the appropriate technical service department identified in the respective Parker product catalog.
2.10 Specifications and Standards: When selecting Valves, government, industry and Parker specifications and recommendations must be reviewed and followed as
applicable.
2.11 Accessories: All accessories used in conjunction with any Parker Valve product must be rated to the same requirements of the Valve including but not limited to
pressure, flow, material compatibility, power requirements. All of these items must be examined as stated in the “VALVE INSTALLATION INSTRUCTIONS”
paragraph 3.0.
(continued on next page)
SG HY14-1000, 2/12/07
3.0 VALVE INSTALLATION INSTRUCTIONS
3.1 Component Inspection: Prior to use, a careful examination of the Valve(s) must be performed. The Valve intended for use must be checked for correct style, size,
catalog number and external condition. The Valve must be examined for cleanliness, absence of external defects or gouges, cracked or otherwise deformed parts or
missing items. The mounting surface or port connections must be protected and free of burrs, scratches, corrosion or other imperfections. Do NOT use any item that
displays any signs of nonconformance. In addition, any accessory including but not limited to fittings, bolt kits, hoses, sub bases, manifolds, and electrical connectors
must be subjected to the same examination.
3.2 Handling Valves: Many Valves whether HVD Valves or of another manufacturer can be large, bulky or otherwise difficult to handle. Care must be taken to use
proper lifting techniques, tools, braces, lifting belts or other aids so as not to cause injury to the user, any other person or to property.
3.3 Filtration: Fluid cleanliness is a necessity in any hydraulic system. Fluid filters must be installed and maintained in the system to provide the required level of fluid
cleanliness. Filters can be placed in the inlets, pressure lines and return lines. The level of cleanliness required is specified in the HVD product catalog for the specific
Valve(s) selected or intended for use. For additional information on Filter selection contact Parker Filter Division at 800-253-1258 or 419-644-4311.
3.4 Servo Valves: Application of Servo Valves in general requires knowledge and awareness of “closed loop control theory” and the use of electronic controls for
successful and safe operation. Individuals who do not have such experience or knowledge must gain training before use of such Products. Parker offers both
classroom training as well as manuals to assist in gaining this knowledge. These aids can be obtained by contacting Hydraulic Valve Division at 440-366-5100,
calling the general Parker help line 800-CPARKER or going to the Parker web site at www.parker.com.
3.5 Accessory Ratings: All accessories used in combination with the selected or intended Valve product must be rated and compatible with the selected Valve.
Specifically, the items must be of equal or greater rating including but not limited to pressure, flow, power, size, port style, thread connectors and material.
3.6 Connection Styles: It is the responsibility of the user of the Parker product to properly select connectors and accessories that match the connections on the sub plate,
Valve, flange or threaded connection or manifold. It is also the responsibility of the installer to possess adequate skill and knowledge including but not limited to
thread preparation, torque technique, hose assembly and inspection, tube preparation and assembly, and fitting installation. Parker Tube Fitting Division
(www.parker.com/tfd) catalog 4300 and Parker Hose Products (www.parkerhose.com) catalog 4400 describe some basic technical information relative to proper
fitting assembly.
3.7 Electrical Connections: All electrical connections must be made to the applicable codes and local safety requirements.
3.8 Gauges and Sensors: The user must install sufficient gauges and sensors in the system so as to be able to determine the condition of the system. This includes but is
not limited to pressure gauges, flow meters, temperature sensors and site gauges. These are of utmost importance should removal or disassembly of a Valve, portion
of a Valve or portion of the system become necessary. Refer to “VALVE MAINTENANCE AND REPLACEMENT INSTRUCTIONS” for details and especially
item 4.8.
3.9 System Checkout: Once installed, the Valve installation must be tested to insure proper operation and that no external leakage exists. All safety equipment must be in
place including but not limited to safety glasses, helmets, ear protection, splash guards, gloves, coveralls and any shields on the equipment. All air entrapment must be
eliminated and the system pressurized to the maximum system pressure (at or below the Valve maximum working pressure) and checked for proper function and
freedom from leaks. Personnel must stay out of potentially hazardous areas while testing and using.
4.0 VALVE MAINTENANCE AND REPLACEMENT INSTRUCTIONS
4.1 Maintenance Program: Even with proper installation, Valves and Valve System life may be significantly reduced without a continuing maintenance program. The
severity of the application and risk potential must determine the frequency of the inspection and the replacement of the Products so that Products are replaced before
any failure occurs. A maintenance program must be established and followed by the user and, at a minimum, must include instructions 4.2 through 4.10. An FMEA
(Failure Mode and Effects Analysis) is recommended in determining maintenance requirements.
4.2 Visual Inspection-Valves: Any of the following conditions require immediate shut down and replacement of the Valve.
Evidence that the Valve is in partial dis-assembly.
Visible crack or suspicion of a crack in the Valve housing or bent, cracked or otherwise damaged solenoid.
Missing or partially extending drive pin on a flow control knob.
Missing, loose components, obstructions or other condition impeding the motion or function of the manual knob, lever, foot pedal or other mechanical operator of
a hydraulic Valve.
Any evidence of burning or heat induced discoloration.
Blistered, soft, degraded or loose cover of any kind.
Loose wire or electrical connector.
4.3 Visual Inspection-Other: The following conditions must be tightened, repaired, corrected or replaced as required.
1. Fluid on the ground must be cleaned immediately. Also, the source of the fluid must be determined prior to running the equipment again.
2. Leaking port or excessive external dirt build-up.
3. System fluid level is too low or air is entrapped or visible in the reservoir.
4. Equipment controlled by the Valve or Valve assembly has been losing power, speed, efficiency
4.4 Filter Maintenance: System filters must be maintained and kept in proper working order. The main service requirement is periodic replacement of the filter element
or screen. Contact Parker Filter Division at 800-253-1258 or 419-644-4311 for further filter maintenance details.
4.5 Functional Test: See “System Checkout” number 3.9 above in “VALVE INSTALLATION INSTRUCTIONS”.
4.6 Replacement Intervals: Valves and Valve Systems will eventually age and require replacement. Seals especially should be inspected and replaced at specific
replacement intervals based on previous experience, government or industry recommendations, or when failures could result in unacceptable downtime, damage or
injury risk. At a minimum seals must be replaced whenever service is rendered to a Valve product.
4.7 Adjustments, Control Knobs, and Other Manual Controls: System Pressure and Flow are typically adjusted by knobs and/or handles. A set-screw or lock-nut
secures the adjustment device so as to maintain the desired setting. This set-screw or lock-nut must first be loosened prior to making any adjustments and re-tightened
after adjustment on the HVD Valve. All adjustments must be made in conjunction with pressure gauges and/or flow meters (or by watching the speed of the actuator
in the case of setting flow only). See paragraph “Gauges and Sensors” above in the section “VALVE INSTALLATION INSTRUCTIONS’. Under no circumstances
should any control knob, adjustment stem, handle, foot pedal or other actuating device be forced beyond the mechanical stop(s) on the Valve. For example, the Parker
Safety Notice Bulletin HY14-3310-B1/US for HVD Colorflow Valves specifically restricts the adjustment torque to “hand adjust” or “less than 10 ft/lbs” if it cannot
be adjusted by hand. Failure to adhere to this may force the knob beyond the stop point allowing it to be ejected at high speed resulting in death, personal injury and
property damage. For complete safety instructions on HVD Colorflow Valves, copies of Safety Notice Bulletin HY14-3310-B1/US can be obtained directly from the
Hydraulic Valve Division at 440-366-5100 or from the Parker web site at www.parker.com
by selecting the “Safety” button. Parker help line 800-CPARKER is on
call 24/7 as well should there be any question about the use of a HVD Valve. Additionally, when making adjustments, always adjust the Valve with all parts of your
body to the side of the Valve (that is, the knob is not pointing toward you or anyone else).
4.8 High pressure Warning: Hydraulic power is transmitted by high-pressure fluids through hoses, fittings and valves, pumps and actuators. This condition can be
dangerous and potentially lethal and, therefore, extreme caution must be exercised when working with fluids under pressure. From time to time, hoses, Valves, tubes
or fittings fail if they are not replaced at proper time intervals. Typically these failures are the result of some form of misapplication, abuse, wear, or failure to perform
proper maintenance. When such failure occurs, generally the high pressure fluid inside escapes in a stream which may or may not be visible to the user. Under no
circumstances should the user attempt to locate the leak by “feeling” with their hands or any other part of their body. High-pressure fluids can and will penetrate the
skin and cause severe tissue damage and possible loss of limb or life. Even seemingly minor hydraulic fluid injection injuries must be treated immediately by a
physician with knowledge of the tissue damaging properties of hydraulic fluid.
If a hose, tube, fitting or Valve failure occurs, immediately shut down the equipment and leave the area until pressure has been completely released from the system.
Simply shutting down the pump may or may not eliminate the pressure in the system. It may take several minutes or even hours for the pressure to be relieved so that
the leak area can be examined safely. Once the pressure has been reduced to zero, the suspected leaking item can be taken off the equipment and examined. It must
always be replaced if a failure has occurred. Never attempt to patch or repair a connector (especially a hose) or Valve that has failed. Consult the nearest Parker
distributor or the appropriate Parker division for component replacement information. Never touch or examine a failed hydraulic component unless it is obvious that
the item no longer contains fluid under pressure.
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
24
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
(continued on next page)
4/07
Parker Hydraulics International Sales Offices
Europe
Ireland
Parker Hannifin Ireland Ltd.
Blackthorn Close,
Stillorgan Industrial Park
Blackrock, Co Dublin, Ireland
Tel: 353 1 293 9999
Fax 353 1 293 9900
Italy
Parker Hannifin S.p.A.
Via Privata Archimede 1
20094 Corsico (MI), Italy
Tel: 39 02 451921
Fax: 39 02 4479340
Latvia (Lithuania, Kaliningrad)
Parker Hanifin Corpration
79A Slokas Street, Office No. 6
LV-1007 Riga, Latvia
Tel: 371 74 52 601
Fax: 371 74 52 608
The Netherlands
Parker Hannifin B.V.
Edisonstraat 1
NL-7575 AT Oldenzaal,
The Netherlands
Tel: 31 541 585 000
Fax: 31 541 585 459
Norway
Parker Hannifin A/S
Berghagan
PO Box 3008
NO-1402 Ski, Norway
Tel: 47 64 911000
Fax: 47 64 911090
Poland
Parker Hannifin Sp z.o.o.
ul. Równolegla 8
PL 02-435 Warsaw, Poland
Tel: 48 22 573 24 00
Fax: 48 22 573 24 03
Portugal
Parker Hannifin Portugal, Lda.
Travessa da Bataria 184 R/C
Dto./1 Esq.
PT-Leça da Palmeira-4450-625, Portugal
Tel: 351 22 9997360
Fax: 351 22 9961527
Romania
Hidro Consulting Impex SRL
Bucaresti Parker Representative Office
Bld. Ferdinand nr. 27 Sector 2
RO-00001 Bucarest, Romania
Tel: 0040 21 252 1382
Fax: 0040 21 252 3381
Russia
Moscow
Parker Hannifin LLC
Rossolimo st., 17, floor 4
RU-119021 Moscow, Russia
Tel: 7 095 580 91 45
Fax: 7 095 580 91 45
Sakhalin
Parker Hannifin LLC
Branch Office Sakhalin
Zheleznodorozhnaya str., 174-A
RU-693008 Yuzhno-Sakhalinsk, Russia
Tel: 7 4242 77 95 48
Fax: 7 4242 77 27 42
Europe
Europe Hydraulics Group
Parker Hannifin Corporation
Parker House
55 Maylands Avenue
Hemel Hempstead, Herts
HP2 4SJ England
Tel: 44 1442 458000
Fax: 44 1442 458085
Austria
Parker Hannifin GmbH
Badener Strasse 12
AT-2700 Wiener Neustadt, Austria
Tel: 43 2622 23501-970
Fax: 43 2622 23501-977
Belarus
Parker Hannifin Corporation
Pr. Nezavisimosti, 11, Office 524
BY-220030 Minsk, Belarus
Tel: 375 17 209 9399
Fax: 375 17 209 9227
Belgium
Parker Hannifin SA NV
ZI Sud 2
23, Rue du Bosquet
BE-1400 Nivelles, Belgium
Tel: 32 67 280 900
Fax: 32 67 280 999
Czech Republic/Slovakia
Parker Hannifin s.r.o.
Parkerova 623
CZ-250 67 Klecany, Czech Republic
Tel: 420 284 083 111
Fax: 420 284 083 112
Denmark
Parker Hannifin Denmark A/S
Industriparken 35-37
DK-2750 Ballerup, Denmark
Tel: 45 43 56 04 00
Fax: 45 43 73 31 07
Finland
Parker Hannifin Oy
Ylästöntie 16
FI-01510 Vantaa, Finland
Tel: 358 20 753 2500
Fax: 358 20 753 2200
France
Parker Hannifin France SAS
142, rue de la Forêt
FR-741 30 Contamine sur Arve, France
Tel: 33 4-50 25 80 25
Fax: 33 4-50 03 67 37
Germany/Switzerland
Parker Hannifin GmbH & Co. KG
Pat-Parker-Platz 1
DE-41564 Kaarst, Germany
Tel: 49 (0) 2131 4016 0
Fax: 49 (0) 2131 4016 9199
Greece
Parker Hannifin Corporation
197 Syngrou Av.
G-171 21 Athens, Greece
Tel: 0030 210 933-6450
Fax: 0030 210 933-6451
Hungary
Parker Hannifin Corporation
Hungarian Trade Representative
Office
Egressy u. 100
HU-1149 Budapest, Hungary
Tel: 36 1 220 4155
Fax: 36 1 422 1525
North America
Hydraulics Group Headquarters
6035 Parkland Boulevard
Cleveland, OH 44124-4141 USA
Tel: 216-896-3000
Fax: 216-896-4031
Parker Hannifin Canada
Motion & Control Division – Milton
160 Chisholm Drive Milton
Ontario Canada L9T 3G9
Tel: 905-693-3011
Fax: 905-876-0788
Motion & Control Division – Montreal
2001 rue de l'aviation
Dorval, Quebec, H9P 2X6
Tel: 514-684-3000
Fax: 514-684-4191
Motion & Control Division – Calgary
3141B – 18th Street N.E.
Calgary, Alberta T2E 7K8
Tel: 403-291-9284
Fax: 403-291-9285
Mexico
Parker Hannifin de Mexico, S.A. C.V
Via de Ferrocarril a Matamoros 730
Apodaca, N.L. C.P. 66600, Mexico
Tel: 01-8181-566036 y 96
Parker Hannifin de México
Av eje uno norte num 100
Parque Industrial Toluca 2000
Toluca, Mex C.P. 50100
Tel: 52 722 2754200
Fax: 52 722 2799308
Mobile Sales
Mobile Systems Division
595 Schelter Road
Suite 100
Lincolnshire, IL 60069 USA
Tel: 847-821-1500
Fax: 847-821-7600
Industrial Sales
Great Lakes Region
3700 Embassy Parkway Suite 260
Fairlawn, OH 44333 USA
Tel: 330-670-2680
Fax: 330-670-2681
Southern Region
1225 Old Alpharetta Road Suite 290
Alpharetta, GA 30005 USA
Tel: 770-619-9767
Fax: 770-619-9806
Chicago Region
1163 E. Ogden Avenue
Suite 705, #358
Naperville, IL 60563 USA
Tel: 630-964-0796
Fax: 866-473-9274
Pacific Region
8460 Kass Drive
Buena Park, CA 90621
Tel: 714-228-2510
Fax: 714-228-2511
Eastern Region
100 Corporate Drive
Lebanon, NJ 08833 USA
Tel: 908-236-4121
Fax: 908-236-4146
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
25
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
4/07
Parker Hydraulics International Sales Offices
Europe
Slovenia
Parker Hannifin Corporation
Vel. Bucna vas 7
SI-8000 Novo Mesto, Slovenia
Tel: 386 7337 6650
Fax: 386 7337 6651
Spain
Parker Hannifin España SA
Parque Industrial Las Monjas
Calle Estaciones 8
28850 Torrejón de Ardoz
Madrid, Spain
Tel: 34 91 6757300
Fax: 34 91 6757711
Sweden
Parker Hannifin AB
Fagerstagatan 51
Box 8314
SE-163 08 Spånga, Sweden
Tel: 46 8 5979 50 00
Fax: 46 8 5979 51 10
Parker Hannifin AB
Almenäsvägen 22
Box 8314
SE-501 7B Borås, Sweden
Tel: 46 33 700 52 00
Fax: 46 33 13 89 40
Turkey
Parker Hannifin Corporation
Merter Is Merkezi
Gen. Ali Riza Gurcan cad. No: 2 / 67
TR-34067 Merter, Istanbul, Turkey
Tel: 90 212 482 91 06
Fax: 90 212 482 91 10
Ukraine
Parker Hannifin Corporation
vul. Velyka Vasylkivska 9/2 Office 59
UA-01004 Kyiv, Ukraine
Tel: 380 44 494 2731/2732/2724
Fax: 380 44 494 2730
United Kingdom
Parker Hannifin Ltd
Tachbrook Park Drive
Tachbrook Park
UK-Warwick, CV34 6 TU, England
Tel: 44 1926 317 878
Fax: 44 1926 317 855
South Africa
Parker Hannifin Africa Pty Ltd
Parker Place
10 Berne Avenue Aeroport
P.O. Box 1153
ZA-Kempton Park 1620,
Republic of South Africa
Tel: 27 11 961 0700
Fax: 27 11 392 7213
Middle East
Azerbaijan
Parker Hannifin plc
Azpar, Technical Representative
140 Alovsat Guliyev St. Apt. 10
AZ-1000 Baku, Azerbaijan
Tel: 99 412 498 3966
Fax: 99 412 498 3966
Middle East
Egypt
Parker Hannifin Corpration
8B Zahraa Maadi
Region 17F
Cairo, Egypt
Tel: (20) 2 5194018
Fax: (20) 2 5190605
Kazakhstan
Parker Hannifin
Gateway Ventures CA Ltd
Representative
7A Kabanbai Batira
KZ-480100 Alamty, Kazakhstan
Tel: 7 3272 505 800
Fax: 7 3272 505 801
Asia Pacific
Asia Pacific Headquarters
Parker Hannifin Hong Kong Ltd.
8/F, Kin Yip Plaza
9 Cheung Yee Street
HK-Cheung Sha Wan, Hong Kong
Tel: 852 2428 8008
Fax: 852 2480 4256
Australia Headquarters
Parker Hannifin Pty Ltd.
9 Carrington Road
Castle Hill, NSW 2154, Australia
Tel: 612 9634 7777
Fax: 612 9842 5111
China Headquarters
Parker Hannifin Motion & Control
(Shanghai) Co., Ltd.
280 Yunqiao Road,
Jin Qiao Export Processing Zone
CN-Shanghai 201206, China
Tel: 86 21 5031 2525
Fax: 86 21 5834 3714
Parker Tejing
Hydraulic Tianjin
21 Hongyuan Road
Xiqing Development Zone
CN-Tianjin 300385, China
Tel: 86 22 5838 8899
Fax: 86 22 5838 8917
India
Parker Hannifin India Pvt Ltd
Plot No. EL-26, MIDC, TTC Industrial Area
Mahape,
IN-Navi Mumbai 400 709, India
Tel: 91 22 5613 7081/7082/7083/7084
Fax 91 22 2768 6841/6618
Japan
Parker Hannifin Japan Ltd
Shirokanedai Building 2nd Floor
3-2-10, Shirokanedai, Minato-ku
JP-Tokyo, 108-0071, Japan
Tel: 81 3 6408 3900
Fax: 81 3 5449 7201
Korea Headquarters
Parker Hannifin Korea Ltd
6F Daehwa Plaza
169 Samsung-dong, Gangnam-gu
KR-Seoul, 135-090, Korea
Tel: 82 2 559 0400
Fax: 82 2 556 8187
Asia Pacific
Malaysia
Parker Hannifin Singapore Pte Ltd
(Malaysia Branch Office)
Lot 558A, Jalan Subang 3
Off Persiaran Subang
Sungai Penaga Industrial Park
MY-47610 Subang Jaya, Malaysia
Tel: 60 (0)3 5638 1476
Fax: 60 (0)3 5638 1527
New Zealand
Parker Hannifin (N.Z.) Ltd
3 Bowden Road
Mt. Wellington, Aukland, New Zealand
Tel: 64 9 574 1744
Fax: 64 9 573 1529
Singapore
Parker Hannifin Singapore
No. 11, Fourth Chin Bee Road
SG-Singapore, 619702
Republic of Singapore
Tel: 65 6887 6300
Fax: 65 6265 5125
Taiwan
Parker Hannifin Taiwan Co., Ltd
No. 40, Wuchiuan 3rd Rd.,
Wuku Industrial Park
Taipei County, Taiwan 248, R.O.C.
Tel: 886 2 2298 8987
Fax: 886 2 2298 8982
Thailand
Parker Hannifin Thailand Co., Ltd
1023, 3rd floor, TPS building
Pattanakarn Road, Suanluang
Bangkok 10250, Thailand
Tel: 662 717 8140
Fax: 662 717 8148
Latin America
Pan American Division
7400 NW 19th Street, Suite A
Miami, FL 33126 USA
Tel: 305-470-8800
Fax: 305-470-8808
Argentina
Parker Hannifin Argentina SAIC
Stephenson 2711 esq. Costa Rica
1667 Tortuguitas
Buenos Aires, Argentina
Tel: 54 3327 44 4129
Fax: 54 3327 44 4199
Brazil
Hydraulics Division
Parker Hannifin Ind. e Com. Ltda
Av. FredericoRitter, 1100
Cachoeirinha RS, 94930-000 Brazil
Tel: 55 51 3470 9144
Fax: 55 51 3470 3100
Chile
Parker Hannifin Chile Ltda
Av. Americo Vespucio 2760-E
Conchali - Santiago, Chile
Tel: 56-2-623-1216
Fax: 56-2-623-1421
Venezuela
Parker Hannifin de Venezuela, SA
Av. Principal con calle Miraima
Edificio Draza, Boleita Norte
Caracas, Venezuela
Tel: 58 212 238 5422
Fax: 58 212 239 2272
Directional Control ValvesBulletin HY14-2502-B1/US
Bul HY14-2502-B1.p65, dd
26
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Notes
Parker’s Charter
To be a leading worldwide manufacturer of components
and systems for the builders and users of durable goods.
More specifically, we will design, market and manufac-
ture products controlling motion, flow and pressure.
We will achieve profitable growth through premier
customer service.
Product Information
North American customers seeking product infor-
mation, the location of a nearby distributor, or repair
services will receive prompt attention by calling the
Parker Product Information Center at our toll-free
number: 1-800-C-PARKER (1-800-272-7537). In Europe,
call 00800-C-PARKER-H (00800-2727-5374).
About Parker Hannifin Corporation
Parker Hannifin is a leading global motion-control
company dedicated to delivering premier customer
service. A Fortune 500 corporation listed on the New
York Stock Exchange (PH), our components and sys-
tems comprise over 1,400 product lines that control
motion in some 1,000 industrial and aerospace mar-
kets. Parker is the only manufacturer to offer its
customers a choice of hydraulic, pneumatic, and
electromechanical motion-control solutions. Our Com-
pany has the largest distribution network in its field,
with over 7,500 distributors serving nearly
400,000 customers worldwide.
Parker Hannifin Corporation
6035 Parkland Blvd.
Cleveland, Ohio 44124-4141
Telephone: (216) 896-3000
Fax: (216) 896-4000
www.parker.com
6/99
The Fluid Connectors
Group designs, manufactures
and markets rigid and flexible
connectors, and associated
products used in pneumatic
and fluid systems.
The Hydraulics Group
designs, produces and markets
a full spectrum of hydraulic
components and systems to
builders and users of industrial
and mobile machinery and
equipment.
The Automation Group
is a leading supplier of pneu-
matic and electromechanical
components and systems to
automation customers world-
wide.
The Seal Group designs,
manufactures and distributes
industrial and commercial
sealing devices and related
products by providing
superior quality and total
customer satisfaction.
The Filtration Group
designs, manufactures and
markets quality filtration and
clarification products, provid-
ing customers with the best
value, quality, technical sup-
port, and global availability.
The Instrumentation
Group is a global leader in
the design, manufacture and
distribution of high-quality
critical flow components for
worldwide process instrumen-
tation, ultra-high-purity, medi-
cal and analytical applications.
The Aerospace Group is
a leader in the development,
design, manufacture and ser-
vicing of control systems and
components for aerospace and
related high-technology mar-
kets, while achieving growth
through premier customer
service.
The Climate & Industrial
Controls Group
designs,
manufactures and markets sys-
tem-control and fluid-handling
components and systems to
refrigeration, air-conditioning
and industrial customers
worldwide.
Parker Hannifin Corporation
Catalog HY14-2502-B1/US,
10/09
Parker Hannifin Corporation
Hydraulic Valve Division
520 Ternes Avenue
Elyria, Ohio, USA 44035
Tel: (440) 366-5200
Fax: (440) 366-5253
www.parker.com/hydraulicvalve