8-33
PSB.PMD CM
Pressure Switch
Series PSB
Catalogue HY11-2500/UK
8
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Kaarst, Germany
Characteristics
Symbol DIN 24340
Design plunger type switch
Mounting pattern PSB*F1* flange (front face)
PSB*G1* flange (right angle)
PSB*R2* pipe thread G¼ (front face, Ø19mm)
PSB*R3* pipe thread G¼ (front face, Ø22mm)
Ports PSB*F1/G1* via subplate
PSB*R2/R3 pipeline connection
Mounting position as desired
Weight [kg] 1.0
Operating pressure [bar] to 315
Actuating pressure difference see diagram
Duty cycle max. 1/s
Pressure fluid mineral oil (HL, HLP) as per DIN 51524, other pressure fluid on request
Temperature range [°C] 0...80
Viscosity range [mm²/s] 12...400
Electrical connection plug-in connector to EN 175301-803
Insulation IP65 as per DIN 40050
Contact load carrying capacity 5A at 250VAC; 1A at 50VDC; 0.2A at 250VDC
General
The electro-hydraulic pressure switch provides an electric
signal when sensed pressure rises above or falls below
the selected setting.
Function
The spring loaded piston is hydraulically dampened. The
pressure difference cannot be set, but is given by the
switch hysteresis.
The required operating pressure is adjusted by a set-
screw. Unauthorised adjustments may be prevented by
fitting a cylinder lock. The electric element is a micro
switch with snap-action contact. Three terminals permit
application as "On", "Off" or "Changeover" switch.
The electrical connection is made with a 3-pole plug-in
connector to DIN 43650 with ground.
Features
• Flange mounting
• Actuating pressure adjustable
• Can be used as opener or closer
• Cylinder lock possible
Technical data
Note
For inductive DC loads a spark discharger should be used
to increase service life.