Catalog HY15-3501/US
Parker Hannifin Corporation
Hydraulic Cartridge Systems
Check
Valves
Shuttle
Valves
Load/Motor
Controls
Flow
Controls
Pressure
Controls
Logic
Elements
Directional
Controls
Manual
Valves
Solenoid
Valves
Proportional
Valves
Coils &
Electronics
Bodies &
Cavities
Technical
Data
SH
CV
LM
FC
PC
LE
DC
MV
SV
PV
CE
BC
TD
PV47
Proportional Flow Regulator Valve
Series HP04P 21Technical Information
Specifications
Rated Flow @ 23 LPM (6 GPM)
210 Bar (3000 PSI)
Hysteresis @ <10%
100 Hz PWM
Closing Point 65% of Rated Current
Variation of Standard Model
Closing Point Up To ±5% Of Rated Current
Model “L”
±2% Of Rated Current
Cartridge Material All parts steel. All operating
parts hardened steel.
Operating Temp. -40°C to +93.3°C (Nitrile)
Range/Seals (-40°F to +200°F)
-31.7°C to +121.1°C (Fluorocarbon)
(-25°F to +250°F)
Fluid Mineral-based or synthetic with
Compatibility/ lubricating properties at viscosities
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
Filtration ISO Code 16/13,
SAE Class 4 or better
Approx. Weight .12 kg (.26 lbs.)
Cavity C10-2
(See BC Section for more details)
General Description
2 Way, Normally Open, Proportional Flow Regulator
Valve. Partially Pressure Compensated. For additional
information see Technical Tips on pages PV1-PV6.
Features
•
Analog Proportional Partially Pressure Compensated
Flow Regulator regulates flow proportionally to the input
solenoid current
•
The valve is designed to be used in applications where
fine pressure compensation is not required and an
exonomical solution is important
•
One piece cartridge housing ensures internal
concentricity
•
Coil: Waterproof, hermetically sealed, requires no
O’Rings; Symmetrical coil can be reversed without
affecting performance.
•
Nonmagnetic spool and housing assembly
•
Factory-adjusted low variation option (Model “L”) is
available for applications where low variation of flow from
valve to valve is essential at a given current or when an
external pressure compensator is used.
•
All external parts zinc plated
Performance Curves
PWM Current Regulator Recommended
(2)
(1)
(1)
(2)
Input Current (%)
8020 40 60
0
100
0
4
8
15.2
30.4
12 45.5
GPM LPM
Flow
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
Flow vs. Input Current
Pressure Differential
42
600
Bar
PSI
84
1200
0
126
1800
168
2400
210
3000
0
Flow
30.4
15.2
8
4
12 45.5
GPM LPM
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
Flow Regulation
Measured at de-energized coil