Catalog HY15-3501/US
Parker Hannifin Corporation
Hydraulic Cartridge Systems
Check
Valves
Shuttle
Valves
Load/Motor
Controls
Flow
Controls
Pressure
Controls
Logic
Elements
Directional
Controls
Manual
Valves
Solenoid
Valves
Proportional
Valves
Coils &
Electronics
Bodies &
Cavities
Technical
Data
SH
CV
LM
FC
PC
LE
DC
MV
SV
PV
CE
BC
TD
PV47
Proportional Flow Regulator Valve
Series HP04P 21Technical Information
Specifications
Rated Flow @ 23 LPM (6 GPM)
210 Bar (3000 PSI)
Hysteresis @ <10%
100 Hz PWM
Closing Point 65% of Rated Current
Variation of Standard Model
Closing Point Up To ±5% Of Rated Current
Model “L
±2% Of Rated Current
Cartridge Material All parts steel. All operating
parts hardened steel.
Operating Temp. -40°C to +93.3°C (Nitrile)
Range/Seals (-40°F to +200°F)
-31.7°C to +121.1°C (Fluorocarbon)
(-25°F to +250°F)
Fluid Mineral-based or synthetic with
Compatibility/ lubricating properties at viscosities
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
Filtration ISO Code 16/13,
SAE Class 4 or better
Approx. Weight .12 kg (.26 lbs.)
Cavity C10-2
(See BC Section for more details)
General Description
2 Way, Normally Open, Proportional Flow Regulator
Valve. Partially Pressure Compensated. For additional
information see Technical Tips on pages PV1-PV6.
Features
Analog Proportional Partially Pressure Compensated
Flow Regulator regulates flow proportionally to the input
solenoid current
The valve is designed to be used in applications where
fine pressure compensation is not required and an
exonomical solution is important
One piece cartridge housing ensures internal
concentricity
Coil: Waterproof, hermetically sealed, requires no
O’Rings; Symmetrical coil can be reversed without
affecting performance.
Nonmagnetic spool and housing assembly
Factory-adjusted low variation option (Model “L”) is
available for applications where low variation of flow from
valve to valve is essential at a given current or when an
external pressure compensator is used.
All external parts zinc plated
Performance Curves
PWM Current Regulator Recommended
(2)
(1)
(1)
(2)
Input Current (%)
8020 40 60
0
100
0
4
8
15.2
30.4
12 45.5
GPM LPM
Flow
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
Flow vs. Input Current
Pressure Differential
42
600
Bar
PSI
84
1200
0
126
1800
168
2400
210
3000
0
Flow
30.4
15.2
8
4
12 45.5
GPM LPM
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
Flow Regulation
Measured at de-energized coil
Catalog HY15-3501/US
Parker Hannifin Corporation
Hydraulic Cartridge Systems
Check
Valves
Shuttle
Valves
Load/Motor
Controls
Flow
Controls
Pressure
Controls
Logic
Elements
Directional
Controls
Manual
Valves
Proportional
Valves
Coils &
Electronics
Technical
Data
SH
CV
LM
FC
PC
LE
DC
MV
SV
PV
CE
BC
TD
Bodies &
Cavities
Solenoid
Valves
Proportional Flow Regulator Valve
Series HP04P 21
PV48
Technical Information
Filter
Screen
Override
Option
Coil
Type
Coil
Termination
Code Filter Screen
0 Not Available
Coil
Voltage
HP04P
10 Size
Proportional
Valve
Style
Code Override Option
0 Not Required
5 Detented M.O.
(Infinite Control)
Dimensions
Millimeters (Inches)
Ordering Information
THIRD-ANGLE
PROJECTION
Code Style (Maximum
Regulated Flow)
21 High Flow (‘SP’ Coil)
30 LPM (8 GPM)
Code Seals / Kit No.
N Nitrile / Buna-N (Std.)
(SK30503N-1)
V Fluorocarbon /
(SK30503V-1)
Seals
21
Opening
Point
Variation
Code Flow Variation
Omit Standard Up to ±5%
of Current Flow
L Low Variation
(±2% of Current Flow)
22.0
(0.86)
66.5
(2.62)
36.0
(1.43)
XXVDC XXW
CAX XXX H
PAT.XXXXXXX
MADEINU.S.A.
7/8-14 UNF
15.8
(0.62)
(2)
(1)
97.3
(3.83)
5.59
(0.22)
50.0
(1.97)
13.21
(0.52)
8.38
(0.33)
Manual Override
(Infinite Control)
3/4 Hex.
4.1 Nm
(3 lb. ft.)
Torque
1 Hex.
30 Nm (22 lb. ft.)
Torque
See Super Coil
5/8" I.D.
Information For
Terminal Connectors
Body
Material
Port
Size
* Add “A” for aluminum, omit for steel.
† Steel body only.
Code Port Size Body Part No.
Omit Cartridge Only
4P 1/4 NPTF (B10-2-*4P)
6P 3/8 NPTF (B10-2-*6P)
8P 1/2 NPTF (B10-2-*8P)
6T SAE-6 (B10-2-*6T)
T6T SAE-6 (B10-2-T6T)†
8T SAE-8 (B10-2-*8T)
T8T SAE-8 (B10-2-T8T)†
6B 3/8 BSPG (B10-2-*6B)
Code Body Material
Omit Steel
A Aluminum
Code Coil Voltage
Omit Without Coil
D012 12 VDC
D024 24 VDC
Code Coil Type
Omit Without Coil
SP Super Coil - 28 Watts
Code Coil Termination
Omit Without Coil
D DIN Plug Face
A Amp Jr. Timer*
L Dual Lead Wire*
H Molded Deutsch*
See Super Coil 5/8
I.D.
*DC Only