Proportional Flow Regulator Valve
Series HP02P 21Technical Information
Specifications
Rated Flow @ 2 to 1 19 LPM (5 GPM)
210 Bar (3000 PSI)
Preferable Input Port 1
Port For Best
Hysteresis
Hysteresis @ <10%
100 Hz PWM
Variation of Flow Standard Model
@ 35% of Rated Up To ±20% Of Rated Flow
Current & Constant Model “L”
∆∆
∆∆
∆P Maintained By ±7% Of Rated Flow
Pressure
Compensator
Cartridge Material All parts steel. All operating
parts hardened steel.
Operating Temp. -40°C to +93.3°C (Nitrile)
Range/Seals (-40°F to +200°F)
-31.7°C to +121.1°C (Fluorocarbon)
(-25°F to +250°F)
Fluid Mineral-based or synthetic with
Compatibility/ lubricating properties at viscosities
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
Filtration ISO Code 16/13,
SAE Class 4 or better
Approx. Weight .08 kg (.17 lbs.)
Cavity 2X
(See BC Section for more details)
General Description
2 Way, Normally Open, Proportional Flow Regulator
Valve. Partially Pressure Compensated. For additional
information see Technical Tips on pages PV1-PV6.
Features
•
Analog Proportional Partially Pressure Compensated
Flow Regulator regulates flow proportionally to the input
solenoid current
•
The valve is designed to be used in applications where
fine pressure compensation is not required and an
economical solution is important
•
One piece cartridge housing ensures internal
concentricity
•
Coil: Waterproof, hermetically sealed, requires no
O’Rings; Symmetrical coil can be reversed without
affecting performance.
•
Nonmagnetic spool and housing assembly
•
Factory-adjusted low variation option (Model “L”) is
available for applications where low variation of flow from
valve to valve is essential at a given current or when an
external pressure compensator is used.
•
All external parts zinc plated
Performance Curves
PWM Current Regulator Recommended
(2)
(1)
(1)
(2)
2 to 1
1 to 2
Pressure
35
500
Bar
PSI
70
1000
105
1500
0
140
2000
175
2500
210
3000
0
Flow
15.2
22.8
7.6
4
6
2
8 30.4
GPM LPM
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
Flow Regulation (Measured at De-Energized Coil)
Input Current (%)
8020 40 60
0
100
0
4 15.2
2 7.6
6 22.8
GPM LPM
Flow
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
Flow vs. Input Current
2 to 1 OR 1 to 2