P.C. Flow Control Valve
Series FC101
Catalog HY15-3501/US
FC27
Check
Valves
Shuttle
Valves
Load/Motor
Controls
Flow
Controls
Pressure
Controls
Logic
Elements
Directional
Controls
Manual
Valves
Solenoid
Valves
Proportional
Valves
Coils &
Electronics
Bodies &
Cavities
Technical
Data
SH
CV
LM
FC
PC
LE
DC
MV
SV
PV
CE
BC
TD
Parker Hannifin Corporation
Hydraulic Cartridge Systems
Technical Information
Performance CurvesSpecifications
Rated Flow 20.6 LPM (5.5 GPM)
Maximum Inlet 210 Bar (3000 PSI)
Pressure
Cartridge Material All parts steel. All operating
parts hardened steel.
Operating Temp. -40°C to +93.3°C (Nitrile)
Range/Seals (-40°F to +200°F)
-31.7°C to +121.1°C (Fluorocarbon)
(-25°F to +250°F)
Fluid Mineral-based or synthetic with
Compatibility/ lubricating properties at viscosities
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
Filtration ISO Code 16/13,
SAE Class 4 or better
Approx. Weight .23 kg (0.5 lbs.)
Cavity C10-2
(See BC Section for more details)
Form Tool Rougher None
Finisher NFT10-2F
General Description
Pressure Compensated Flow Control. For additional
information see Technical Tips on pages FC1-FC4.
Features
Hardened, precision ground parts for durability
Compact size for reduced space requirements
Free flow in reverse condition
All external parts zinc plated
(1) (2)
(2)
Metered Flow
Outlet
Free Flow
Inlet
(1)
Full Flow Outlet
Metered Flow Inlet
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
0
2
830
23
15
8
Regulated Flow
6
GPM LPM
4
Regulated Flow vs. Pressure Drop
(Through cartridge only)
500
300
100
050
200
400
600
105
1500
140
2000
70
1000
35
500
Bar
PSI
0
170
2500
204
3000
Pressure Drop ( P)
Flow (Q)
15
4
8
2
LPM
GPM
0
23
6
30
8
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
0
50
250 18
11
14
7
4
150
200
PSI Bar
100
Pressure Drop vs. Flow (Through cartridge only)
Pressure Drop ( P)
Catalog HY15-3501/US
P.C. Flow Control Valve
Series FC101
FC28
Check
Valves
Shuttle
Valves
Load/Motor
Controls
Flow
Controls
Pressure
Controls
Logic
Elements
Directional
Controls
Manual
Valves
Proportional
Valves
Coils &
Electronics
Technical
Data
SH
CV
LM
FC
PC
LE
DC
MV
SV
PV
CE
BC
TD
Bodies &
Cavities
Solenoid
Valves
Parker Hannifin Corporation
Hydraulic Cartridge Systems
Technical Information
Dimensions
Millimeters (Inches)
Ordering Information
SealsFlow
Range
Body
Material
Port
Size
Code Seals / Kit. No.
Omit Nitrile / (SK10-2N)
V Fluorocarbon /
(SK10-2V)
Code Adjustment Style
K Knob Adjust (717784-10)
S Screw Adjust
T Tamper Resistant Cap (717783)
Code Body Material
Omit Steel
A Aluminum
10 Size
Pressure
Compensated Flow
Control
FC101
Adjustment
Style
Optional
Setting
Code Flow Range and
Standard Setting
050 1.1-3.8 LPM (.30-1.0 GPM)
(1.9 LPM (.5 GPM) @
69 Bar (1000 PSI) P)
100 2.8-8.3 LPM (.75-2.2 GPM)
(3.8 LPM (1 GPM) @
69 Bar (1000 PSI) P)
300 7.5-16.9 LPM (2.0-4.5 GPM)
(11.3 LPM (3 GPM) @
69 Bar (1000 PSI) P)
600 15-30 LPM (4.0-8.0 GPM)
(22.5 LPM (6 GPM) @
69 Bar (1000 PSI) P)
Optional Setting
Flow setting specified in
.38 LPM (.1 GPM) increments
other than standard
* Add “A” for aluminum, omit for steel.
† Steel body only.
Code Port Size Body Part No.
Omit Cartridge Only
4P 1/4 NPTF (B10-2-*4P)
6P 3/8 NPTF (B10-2-*6P)
8P 1/2 NPTF (B10-2-*8P)
6T SAE-6 (B10-2-*6T)
T6T SAE-6 (B10-2-T6T)†
8T SAE-8 (B10-2-*8T)
T8T SAE-8 (B10-2-T8T)†
6B 3/8 BSPG (B10-2-6B)†
Tamper
Resistant
Ø 15.8
(.62)
31.8
(1.25)
61.0
(2.40)
1" Hex.
22 Nm
(16 lb. ft.)
Torque
Screw and
Knob Adjust -
1/4" Internal Hex.
38.1 (1.50)
Dia. Knob
58.4
(2.30)
Max.
(2)
Metered Flow Outlet
Free Flow Inlet
(1)
Full Flow Outlet
Metered Flow Inlet
7/8-14 UNF-2A
Thread
35.6
(1.40)
THIRD-ANGLE
PROJECTION