Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
9
9-51
Proportional Throttle Valve
Series F5C
F5C UK.INDD CM 02.08.11
Technical data
General
Size 06 (¾") 08 (1") 10 (1¼")
Mounting Flanged according to SAE 61
Mounting position unrestricted
Ambient temperature [°C] -20...+50
Weight [kg] 3.9 4.1 5.8
Hydraulic
Max. operating pressure
Ports A, B, X1, X2, X3 [bar] 350 300 280
Ports Y1, Y2 [bar] 70
Max. pressure drop (from A to B) [bar] 21
Nominal flow [l/min] 95 190 380
Fluid Hydraulic oil according to DIN 51524...51525
Fluid temperature [°C] -20...+80
Viscosity permitted [cSt] / [mm
2
/s] 10...650
recommended [cSt] / [mm
2
/s] 30
Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
Electrical characteristics
Duty ratio [%] 100
Solenoid connection Connector as per EN175301-803
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage [V] 16
Current consumption [A] 1.05
Resistance [Ohm] 11.3
Response time [ms] see ordering code
Coil insulation class H (180 °C)
Technical Data / Characteristic Curves
Characteristic curves
All characteristic curves measured with HLP46 at 50°C.