Catalogue HY17-8249/US
March 2004
Hydraulic
Motor/Pump
Series F11/F12
zp12
Fixed Displacement zp11
Conversion factors
1 kg ............................................................... 2.20 lb
1 N.............................................................. 0.225 lbf
1 Nm........................................................ 0.738 lbf ft
1 bar .............................................................14.5 psi
1 l ....................................................0.264 US gallon
1 cm
3
.......................................................0.061 cu in
1 mm ........................................................... 0.039 in
9
/
5
°C + 32 .......................................................... 1°F
3
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
Catalogue HY17-8249/US
Content
Content Page
General information ................................................ 4
F11 cross section ................................................... 4
F12 cross sections ................................................. 5
Specifications ......................................................... 6
Ordering codes
F11-CETOP............................................................ 7
F11-ISO.................................................................. 8
F11-SAE................................................................. 9
F12-ISO................................................................ 10
F12-Cartridge ....................................................... 11
F12-SAE............................................................... 12
Prefered versions F11/F12 ................................... 13
Technical information
Bearing life ........................................................... 14
Bearing life calculation.......................................... 14
Required information ............................................ 14
Noise level ............................................................ 15
Efficiency .............................................................. 15
Selfpriming speed and required inlet pressure ..... 16
Installation dimensions
F11-5 CETOP....................................................... 17
F11-10 CETOP..................................................... 18
F11-14 CETOP..................................................... 19
F11-19 CETOP..................................................... 20
F11-14 ISO........................................................... 21
F11-14 SAE .......................................................... 22
F11-19 SAE .......................................................... 23
F12-30, -40, -60, -80 and -110 ISO ................ 24-25
F12-30, -40, -60, -80 and -110 Cartridge ........ 26-27
F12-30, -40, -60, -80 and -110 4 bolt flange .... 28-29
F12-30, -40, and -60 2 bolt flange ................... 30-31
F11-150 CETOP ................................................... 32
F11-150 SAE........................................................ 33
F11-250 SAE........................................................ 34
Technical information
F11 saw motors .................................................... 35
F11 fan motors ..................................................... 35
F12 integrated flushing valve ................................ 36
F12 accessory valve blocks .................................. 36
Type BT brake valve ............................................. 37
Type SR pressure relief/make-up valve ................ 37
Type SV pressure relief valve ............................... 38
Speed sensor ....................................................... 38
F12 main port suction fittings ............................... 39
Suction fittings ...................................................... 39
Suction fitting kits ................................................. 39
Split-flange kits ..................................................... 39
Installation information ......................................... 40
Direction of rotation .............................................. 40
Hydraulic fluids ..................................................... 40
Operating temperature ......................................... 40
Installation information
Viscosity ............................................................... 41
Filtration ............................................................... 41
Case pressure ...................................................... 41
Case drain connections ........................................ 42
Before start-up ..................................................... 42
4
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
F11 cross section
1. Barrel housing
2. Valve plate
3. Cylinder barrel
4. Guide spacer
with O-rings
5. Timing gear
6. Roller bearing
7. Bearing housing
8. Shaft seal
9. Output/input shaft
10. Piston with laminated
piston ring
10
123456789
F11 and F12 are bent axis, fixed displacement heavy-
duty motor/pump series. They can be used in numer-
ous applications in both open and closed loop circuits.
Series F11 is available in the following frame sizes
and versions:
- F11-5, -10, -14, 19 and -150 with CETOP mounting
flange and shaft end
- F11-14 with ISO flange and shaft
- F11-14, -19, -150 and -250 with SAE flange and
shaft
Series F12 conforms to current ISO and SAE
mounting flange and shaft end configurations. A very
compact cartridge version is also available.
Thanks to the unique spherical piston design, F11/F12
motors can be used at unusually high shaft speeds.
Operating pressures to 480 bar provides for the high
output power capability.
The 40° angle between shaft and cylinder barrel
allows for a very compact, lightweight motor/pump.
The laminated piston ring offers important
advantages such as low internal leakage and thermal
shock resistance.
The pump version has highly engineered valve plates
for increased selfpriming speed and low noise,
available with left and right hand rotation.
The F11/F12 motors produce very high torque at
start-up as well as at low speeds.
Our unique timing gear design synchronizes shaft
and cylinder barrel, making the F11/F12 very tolerant
to high 'G' forces and torsional vibrations.
Heavy duty roller bearings permit substantial external
axial and radial shaft loads.
The F11's and F12's have a simple and straight-
forward design with very few moving parts, making
them very reliable motors/pumps.
The unique piston locking, timing gear and bearing
set-up as well as the limited number of parts add up
to a very robust design with long service life and,
above all, proven reliability.
Catalogue HY17-8249/US
General information
5
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
1
2
3
4
5
6
7
8
9
1231045678
9
11
F12 cross sections
1. Barrel housing
2. Valve plate
3. Cylinder barrel
4. Piston with piston ring
F12-30, -40, -60 and -80
(F12-60 shown)
5. Timing gear
6. Tapered roller bearings
7. Bearing housing
8. Shaft seal
9. Output/input shaft
10. Port E (F12-110)
11. Needle bearings (F12-110)
F12-110
Legend:
Catalogue HY17-8249/US
General information
6
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
Frame size F11-5 -10 -14 -19 F12-30 -40 -60 -80 -110 F11-150 -250
Displacement [cm
3
/rev] 4.9 9.8 14.3 19.0 30.0 40.0 59.8 80.4 110.1 150 242
[cu in/rev] 0.30 0.60 0.87 1.16 1.83 2.44 3.65 4.91 6.72 9.15 14.8
Operating pressure
max intermittent
1)
[bar] 420 420 480 480 420 420
[psi] 6 000 6 000 7 000 7 000 6 000 6 000
max continuous [bar] 350 350 420 420 350 350
[psi] 5 000 5 000 6000 6000 5 000 5 000
Motor operating speed [rpm]
max intermittent
1)
12 000 11 000 10 000 9 000 7 100 6 400 5 600 5 200 4 700 3 000 2 700
max continuous 10 800 9 900 9 000 8 100 5 600 5 000 4 300 4 000 3 600 2 600 2 400
min continuous 50 50
Max pump selfpriming speed
2)
L or R function; max [rpm] 4 600 4 200 3 900 3 500 3150 2870 2500 2300 2290 1 700 1 500
Motor input flow
max intermittent
1)
[l/min] 58 108 143 171 213 256 335 418 517 450 650
[gpm] 15.3 28.5 37.8 45.2 56.3 67.6 88.5 110.4 136.6 119.0 172.8
max continuous [l/min] 52 97 128 153 168 200 257 322 396 390 580
[gpm] 13.7 25.6 33.8 40.4 44.4 52.8 67.9 85.1 104.6 103.0 153.6
Main circuit temp.
3)
, max [°C] 80 80
[°F] 175 175
min [°C] -35 -35 -30 -35 -35 -35 -35 -35
[°F] -31 -31 -22 -31 -31 -31 -31 -31
Mass moment of inertia
(x10
-3
) [kg m
2
]
0.16 0.39 0.42 1.1 1.7 2.9 5 8.4 11.2 40 46
(x10
-2
)
[lbft
2
] 0.38 0.92 1.00 2.61 4.03 6.88 11.86 19.93 26.58 94.92 109.16
Weight [kg] 5 7.5 8.3 11 12 16.5 21 26 36 70 77
[lb] 11 16.5 18.8 24 26 36 46 57 79 154 170
1) Intermittent: max 6 seconds in any one minute.
2) Selfpriming speed valid at sea level.
3) See also installation information, operating temperature.
Catalogue HY17-8249/US
Specifications
Torque (M)
M = [Nm]
Basic formulas for hydraulic motors
Flow (q)
q = [l/min]
Power (P)
P = [kW]
D x n
1000 x η
v
D x p x η
hm
63
q x p x η
t
600
D - displacement [cm
3
/rev]
n - shaft speed [rpm]
η
v
- volumetric efficiency
p - differential pressure [bar]
(between inlet and outlet)
η
hm
- mechanical efficiency
η
t
- overall efficiency
(η
t
=
η
v
x η
hm
)
7
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
F11-CETOP
x: Available (x): Optional – : Not available
1) Internal drain
2) BSP threads
3) NBR - Nitrile rubber
4) FPM - Fluor rubber
Catalogue HY17-8249/US
Ordering codes
Frame size
Code Displacem.
(cm
3
/rev)
5 4.9
10 9.8
14 14.3
19 19.0
150 150.0
Frame size 5 10 14 19 150
Code Main ports
B BSP threads x x x x -
R With anti-cavitation
valve; clockwise rot’n
2)
-xxx-
L With anti-cavitation
valve; counter clockw.
2)
-xxx-
U SAE, UN threads (x) (x) - (x) -
F SAE 6000 psi flange - - - - x
Frame size 5 10 14 19 150
Code Function
M Motor x x - x x
H Motor, high pressure x x x x x
Q Motor, silent (x) (x) - (x) (x)
J Motor, clockwise rot'n
1)
(x) (x) - (x) (x)
G Motor, counter clockw.
1)
(x) (x) - (x) (x)
R Pump, clockwise rot'n x x x x x
L Pump, counter clockw. x x x x x
Frame size 5 10 14 19 150
Code Mounting flange
C CETOP flange x x x x x
W Saw motor flange - x x x -
Frame size 5 10 14 19 150
Code Shaft seal
N NBR
3)
, low pressure x x - x x
H NBR
3)
, high pressure x x - x x
E FPM
4)
, low pressure,
high temperature x x x x x
V FPM
4)
, high pressure,
high temperature - x x x -
Frame size 5 10 14 19 150
Code Shaft
K Metric key x x x x x
D Spline, DIN 5480 (x) (x) (x) (x) (x)
Version number
(assigned for special
versions)
F11 ——
Frame
size
Function
Main
ports
Mounting
flange
Shaft
seal
Shaft
Version
number
Option
page 36
Option
page 38
Frame size 5 10 14 19 150
Code Option
S With speed sensor - - x x -
P Prepared for speed
sensor - - x x -
Option
None
Pump
Motor
8
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
F11-ISO
x: Available (x): Optional – : Not available
1) FPM - Fluor rubber
Catalogue HY17-8249/US
Ordering codes
Frame size
Code Displacem.
(cm
3
/rev)
14 14.3
Frame size 14
Code Main ports
F SAE 6000 psi flange x
Frame size 14
Code Function
H Motor, high pressure x
R Pump, clockwise rot'n x
L Pump, counter clockw. x
Frame size 14
Code Mounting flange
I ISO flange x
Frame size 14
Code Shaft seal
E FPM
1)
, low pressure,
high temperature x
V FPM
1)
, high pressure,
high temperature x
Frame size 14
Code Shaft
K Metric key x
D Spline, DIN 5480 (x)
Version number
(assigned for special
versions)
F11 ——
Frame
size
Function
Main
ports
Mounting
flange
Shaft
seal
Shaft
Version
number
Option
page 36
Option
page 38
Frame size 14
Code Option
S With speed sensor x
P Prepared for speed
sensor x
Option
None
Pump
Motor
9
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
Catalogue HY17-8249/US
Ordering codes
Pump
Motor
F11-SAE
x: Available (x): Optional – : Not available
1) Internal drain
2) Metric thread
3) BSP threads
4) NBR - Nitrile rubber
5) FPM - Fluor rubber
Frame size
Code Displacem.
(cm
3
/rev)
14 14.3
19 19.0
150 150.0
250 242.0
Frame size 14 19 150 250
Code Main ports
U SAE, UN threads x x - -
B BSP threads - (x) - -
F SAE 6000 psi flange
2)
--xx
R With anti-cavitation
valve; clockwise rot’n
3)
xx- -
L With anti-cavitation
valve; counter clockw.
3)
xx- -
Frame size 14 19 150 250
Code Function
M Motor - x x -
H Motor, high pressure x x x -
Q Motor, silent - (x) (x) x
J Motor, clockwise rot'n
1)
- (x) (x) -
G Motor, counter clockw.
1)
- (x) (x) -
R Pump clockwise rot'n x x x x
L Pump counter clockw. x x x x
Frame size 14 19 150 250
Code Mounting flange
S SAE flange x x x x
Frame size 14 19 150 250
Code Shaft seal
N NBR
4)
, low pressure - x x x
H NBR
4)
, high pressure - x x x
E FPM
5)
, low pressure,
high temperature x x x x
V FPM
5)
, high pressure,
high temperature x x - -
Frame size 14 19 150 250
Code Shaft
T SAE key x x x -
S SAE spline (x) (x) (x) (x)
K Metric key - - - x
F SAE spline - - - (x)
Version number
(assigned for special
versions)
F11 ——
Frame
size
Function
Main
ports
Mounting
flange
Shaft
seal
Shaft
Version
number
Option
page 36
Option
page 38
Frame size 14 19 150 250
Code Option
S With speed sensor x x - -
P Prepared for speed
sensor x x - -
Option
None
10
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
Catalogue HY17-8249/US
Ordering codes
F12-ISO
Frame size
Code Displacem.
(cm
3
/rev)
30 30.0
40 40.0
60 59.8
80 80.4
110 110.1
Frame size 30 40 60 80 110
Code Option
S With speed sensor x x x x x
P Prepared for speed
sensor x x x x x
Frame size 30 40 60 80 110
Code Main ports
F ISO flange x x x x x
Frame size 30 40 60 80 110
Code Shaft seal
H NBR
1)
, high pressure x x x x x
N NBR
1)
, low pressure x x x x x
V FPM
2)
, high temperature, x x x x x
high pressure
Frame size 30 40 60 80 110
Code Shaft
D DIN spline Standard x x x x x
Z Optional (x) (x) - (x) -
K Metric key Standard x x x x x
P Optional (x) - - - -
Frame size 30 40 60 80 110
Code Option
L01 Integr. flushing valve x x x x -
3)
Frame size 30 40 60 80 110
Code Mounting flange
I ISO flange x x x x x
Frame size 30 40 60 80 110
Code Function
M Motor x x x x x
Pump:
L counter clockw. x x x x x
R clockwise x x x x x
x: Available (x) : Optional – : Not available
1) NBR - Nitrile rubber
2) FPM - Fluor rubber
3) F12-110: Accessory valve block (page 36)
Version number
(assigned for
special versions)
F12 ——
Frame
size
Function
Main
ports
Mounting
flange
Shaft
seal
Shaft
Version
number
Option
page 36
Option
page 38
11
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
F12-Cartridge
Catalogue HY17-8249/US
Ordering codes
F12 ——
Frame
size
Function
Main
ports
Mounting
flange
Shaft
seal
Shaft Version
number
Option
page 36
Option
page 38
Frame size
Code Displacem.
(cm
3
/rev)
30 30.0
40 40.0
60 59.8
80 80.4
110 110.1
Frame size 30 40 60 80 110
Code Function
M Motor x x x x x
Frame size 30 40 60 80 110
Code Main ports
F ISO flange x x x x x
Frame size 30 40 60 80 110
Code Mounting flange
C Cartridge x x x x x
Frame size 30 40 60 80 110
Code Shaft seal
H NBR
1)
, high pressure x x x x x
N NBR
1)
, low pressure x x x x x
V FPM
2)
high temperature, x x x x x
high pressure)
Frame size 30 40 60 80 110
Code Shaft
C DIN spline Standard x x x x x
K Metric key Standard x - x x -
X " " Optional - (x) - - -
Frame size 30 40 60 80 110
Code Option
L01 Integr. flushing valve x x x x -
3)
Frame size 30 40 60 80 110
Code Option
S With speed sensor x x x x x
P Prepared for speed
sensor x x x x x
x: Available (x) : Optional – : Not available
1) NBR - Nitrile rubber
2) FPM - Fluor rubber
3) F12-110: Accessory valve block (page 36)
Version number
(assigned for
special versions)
12
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
x: Available (x) : Optional – : Not available
1) NBR - Nitrile rubber
2) FPM - Fluor rubber
3) F12-110: Accessory valve block (page 36)
Catalogue HY17-8249/US
Ordering codes
F12 ——
F12-SAE
Frame size
Code Displacem.
(cm
3
/rev)
30 30.0
40 40.0
60 59.8
80 80.4
110 110.1
Frame
size
Function Main
ports
Mounting
flange
Shaft
seal
Shaft
Version
number
Option
page 36
Option
page 38
Frame size 30 40 60 80 110
Code Option
S With speed sensor x x x x x
P Prepared for speed
sensor x x x x x
Frame size 30 40 60 80 110
Code Main ports
S SAE flange x x x x x
U SAE, UN threads (x) (x) (x) - (x)
Frame size 30 40 60 80 110
Code Shaft seal
H NBR
1)
, high pressure x x x x x
N NBR
1)
, low pressure x x x x x
V FPM
2)
, high temperature, x x x x x
high pressure
Frame size 30 40 60 80 110
Code Shaft
S SAE spline Standard xxxxx
U " " Optional - - - (x) -
T SAE key Standard xxxxx
Frame size 30 40 60 80 110
Code Option
L01 Integr. flushing valve x x x x -
3)
Frame size 30 40 60 80 110
Code Mounting flange
S SAE 4 bolt x x x x x
T SAE 2 bolt x x x - -
Frame size 30 40 60 80 110
Code Function
M Motor x x x x x
Pump:
L counter clockw. x x x x x
R clockwise x x x x x
Version number
(assigned for
special versions)
13
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
Prefered versions F11/F12 catalogue
F11
Ordering Codes Part number
F11-005-MB-CN-K 3703665
F11-005-MB-CH-K 3707249
F11-005-HU-CH-K 3707308
F11-010-MB-CN-K 3703603
F11-010-MB-CH-K 3706030
F11-010-HU-CH-K 3707310
F11-014-HB-CE-K 3783201
F11-014-HB-CV-K 3782830
F11-019-MB-CN-K 3703516
F11-019-MB-CH-K 3707893
F11-150-MF-CN-K 3703468
F11-150-MF-CH-K 3707008
F11-150-HF-SH-S 3707325
F11-250-QF-SH-F 3706440
F11-250-QF-SH-K 3795858
F12
Ordering Codes Part number
F12-30-MF-IH-D 3799843
F12-30-MF-IH-K 3799844
F12-30-MS-SH-S 3799851
F12-30-MS-TH-S 3799616
F12-40-MF-IH-D 3799525
F12-40-MF-IH-K 3799526
F12-40-MS-SH-S 3799532
F12-40-MS-SH-T 3799533
F12-40-MS-TH-S 3799617
F12-60-MF-IH-D 3799988
F12-60-MF-IH-K 3799989
F12-60-MS-SH-S 3799998
F12-60-MS-TH-S 3799618
F12-80-MF-IH-D 3780767
F12-80-MF-IH-K 3780772
F12-80-MS-SH-S 3780783
F12-110-MF-IH-D 3781530
F12-110-MF-IH-K 3781534
F12-110-MS-SH-S 3781542
Catalogue HY17-8249/US
Ordering codes
14
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
Life expectancy
(logarithmic scale)
Other
causes
Bearing
fatigue
Rotating group
fatigue and wear
System
pressure
Hydraulic unit life versus system pressure.
Bearing life
General information
Bearing life can be calculated for that part of the load/
life curve (shown below) that is designated 'Bearing
fatigue'. 'Rotating group fatigue and wear' and 'Other'
caused by material fatigue, fluid contamination, etc.
should also be taken into consideration when estimat-
ing the service life of a motor/pump in a specific appli-
cation.
Bearing life calculations are mainly used when compar-
ing different frame sizes. Bearing life, designated B
10
(or L
10
), is dependent of system pressure, operating
speed, external shaft loads, fluid viscosity in the case,
and fluid contamination level.
The B
10
value means that 90% of the bearings survive,
at a minimum, the number of hours calculated. Statisti-
cally, 50% of the bearings will survive at least five
times the B
10
life.
Bearing life calculation
An application is usually governed by a certain duty or
work cycle where pressure and speed vary with time
during the cycle.
In addition, bearing life depends on external shaft
forces, fluid viscosity in the case and fluid conta-
mination.
Parker Hannifin (Mobile Controls Division) has a
computer program for calculating bearing life and will
assist in determining F11 or F12 motor/pump life in a
specific application.
Required information
When requesting a bearing life calculation from Parker
Hannifin (Mobile Controls Division), the following
information (where applicable) should be provided:
- A short presentation of the application
- F11 or F12 size and version
- Duty cycle (pressure and speed versus time
at given displacements)
- Low system pressure
- Case fluid viscosity
- Life probability (B
10
, B
20
, etc.)
- Operating mode (pump or motor)
- Direction of rotation (L or R)
- External shaft loads
- Fixed or rotating radial load
- Distance between flange and radial load
- Angle of attack (α) as defined below
The direction (a) of the radial load is positive in the
direction of rotation as shown.
To obtain maximum bearing life, the radial load should,
in most cases, be located approximately at 170°
(motor; R.H. rot'n) or 190° (pump; R.H rot'n).
Catalogue HY17-8249/US
Technical information
F F
α
15
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
Noise level
Series F11/F12 feature low noise levels from low to
high speeds and pressures.
As an example, the diagram to the right shows the
noise level of an F12-30.
The noise level is measured in a semi-anechoic room,
1 m behind the unit.
The noise level for a particular motor/pump may vary
±2 dB(A) compared to what is shown in the diagram.
NOTE: Noise information for F11/F12 frame
sizes are available from Parker Hannifin.
Efficiency
Because of its high overall efficiency, driving a motor/
pump from series F11/F12 requires less fuel or electric
power. Also, it allows the use of a small reservoir and
heat exchanger, which in turn reduce cost, weight, and
installation size.
The diagrams to the right shows volumetric and
mechanical efficiencies of an F12-30.
Contact Parker Hannifin for efficiency information on a
particular F11/F12 frame size that is being considered.
Catalogue HY17-8249/US
Technical information
Volumetric efficiency.
Mechanical efficiency.
100%
90%
80%
0 1000 2000 3000 4000 Speed
[rpm]
100%
90%
80%
0 1000 2000 3000 4000 Speed
[rpm]
F12-30
(motor)
F12-30
(motor)
3000 psi
6000 psi
6000 psi
3000 psi
Noise level
[dB(A)]
90
85
80
75
70
65
0 1000 2000 3000 4000 5000 Pressure
[psi]
5000 rpm
3500 rpm
2000 rpm
F12-30
(M, L or R function)
16
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
1000 2000 3000 4000 Speed [rpm]
F12-110 -80 -60 -40 -30
1000 2000 3000 4000 Speed [rpm]
F12-110 -80 -60 -40 -30
F12-L or -R
F12-M
Inlet press.
[psi]
30
20
10
0
5 in. Hg vacuum
Inlet press.
[psi]
30
20
10
0
5 in. Hg vacuum
Inlet
pressure
gauge
Function L or RM H
F11-5 4600 3800 3200
F11-10 4200 3100 2700
F11-14 3900 - 3200
F11-19 3500 2400 2100
F11-150 1700 1300 1100
F11-250 1500 950 -
Selfpriming speed and required inlet
pressure
Series F11
In pump applications, the F11 with function L (counter
clockwise rotation) or R (clockwise rotation) is normally
used. The L and R (pump) provide the highest self-
priming speeds (see table) as well as the lowest noise
level. The M (motor) function can also be used as a
pump, in either direction, but at a lower selfpriming
speed.
Operating above the selfpriming speed (refer to
Diagram 1) requires increased inlet pressure.
As an example, at least 1.0 bar is needed when operat-
ing the F11-19-M as a pump at 3500 rpm. An F11 with
H function, used as a motor (e.g. in a hydrostatic
transmission), may sometimes operate as a pump at
speeds above the selfpriming speed; this requires
additional inlet pressure.
Insufficient inlet pressure can cause pump cavitation
resulting in greatly increased pump noise and deterio-
rating performance.
Series F12
When operating the F12 as a pump (with L or R valve
plate) above the selfpriming speed, the inlet must be
pressurized. Increased noise and deteriorating per-
formance may otherwise be experienced.
Diagrams 2 and 3 show required pump inlet pressure
vs. shaft speed.
The F12 motor (type M valve plate) sometimes oper-
ates as a pump e.g. when used in a propel transmis-
sion and the vehicle is going downhill.
Minimum required inlet pressure versus shaft speed is
shown in the diagrams.
Diagram 2.
Min. required pump (F12-L or -R) inlet press.
Diagram 3. Min. required motor (F12-M) inlet pressure.
Diagram 1. Min required inlet pressure (F11-19).
NOTE:
Diagrams 1, 2 and 3 are valid
at sea level.
Catalogue HY17-8249/US
Technical information
H
M
L, R
1000 2000 3000 4000 Speed [rpm]
Inlet pressure
[psi]
30
20
15
10
0
F11-19
5 in. Hg vacuum
17
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
F11-5
(CETOP versions)
Catalogue HY17-8249/US
Installation dimensions
3.31 max
1.50
Main port A
BSP ½"
Main port B
BSP ½"
Drain port C
BSP ¼"
2.56
0.20
1.87
3.48
2.13
1.57
1.18
0.20
40˚
0.35
0.51
5.28 max
Ø0.7090
0.7085
Ø3.1496
3.1478
Ø0.80 min
Approx.
center of
gravity
3.78 max
2.09
4.47
0.31
0.47
min
0.98
0.35
0.79
M6*
0.81
Ø0.43 (x2)
Ø5.00
max
3.94
Drain port D
BSP ¼"
Flange C
Key shaft K
Key 6x6
R 0.03
R 0.02
W18x1,25x13x9g
Type D spline shaft (DIN 5480)
Mounting flange C
* Metric thread
18
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
F11-10
(CETOP versions)
Catalogue HY17-8249/US
Installation dimensions
3.70 max
1.81
Main port A
BSP ¾"
Main port B
BSP ¾"
Drain port C
BSP
3
/8"
3.11
0.43
2.09
3.98
2.48
1.97
1.38
0.28
40˚
0.35
0.55
6.14 max
Ø0.7878
0.7872
Ø3.9370
3.9349
Ø0.91 min
Approx.
center of
gravity
4.57 max
2.24
5.24
0.31
0.47
min
1.18
0.35
0.87
M6*
0.89
Ø0.51 (x2)
Ø5.98
max
4.92
Drain port D
BSP ¼"
Flange C
Key shaft K
Key 6x6
R 0.03
R 0.02
W20x1.25x14x9g
Spline shaft D (DIN 5480)
Mounting flange C
* Metric thread
19
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
F11-14
(CETOP versions)
Catalogue HY17-8249/US
Installation dimensions
B A
25˚
3.94
5.87
6.18
max
0.37
1.65 1.38
0.55
0.14
4.02
1.772.83
2.09
1.26
2.32
R 0.03
5.51
Ø0.51 (x2)
4.49
5.91
39˚ (x4)
0.31
Ø1.06
Ø0.9846
0.9841
4.02
1.81
1.18
0.31
1.10
Ø0.9744
M8x0.63
Ø3.9370
3.9349
R 0.02
1.02
Anticavitation valve
(left or right hand optional;
right hand shown)
Main port A
(BSP 3/4”-A)
W 25x1.25x18x9g
Type D spline
shaft (DIN 5480)
Drain port C
(BSP 3/8”-A)
Speed sensor
(optional)
Flange C
Drain port D
(BSP 3/8”-A)
Type K key shaft
CCW CW
Type C mounting flange
Key 8x7x35
Main port B
(BSP 3/4”-A)
5.24
20
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
F11-19
(CETOP version)
3.46
0.43
2.48
4.49 max
2.13
Drain port D
BSP
3
/8"
Main port A
BSP ¾"
Main port B
BSP ¾"
Drain port C
BSP
3
/8"
Flange C
Key shaft K
Key 8x7x35
R 0.05
max
R 0.04
max
Ø1.11 min
Ø0.9846
0.9841
Ø4.4094
4.4073
2.28
0.98
1.65
6.50 max
1.14
0.98
1.10
0.91
5.43
3.94
0.63
0.39
45˚
4.96
Ø6.69
max
Ø0.55 (x2)
3.42
5.51
Mounting flange C
Approx.
center of
gravity
0.63
min
M8*
1.10
W25x1.25x18x9g
Spline shaft D (DIN 5480)
* Metric thread
Catalogue HY17-8249/US
Installation dimensions
21
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
F11-14
(ISO versions)
Catalogue HY17-8249/US
Installation dimensions
B A
3.98 Main ports M26
(metric thread;
depth 0.47;
ISO 9974-1)
Drain port M26
(metric thread;
depth 0.47;
ISO 9974-1)
Drain port M26
(metric thread;
depth 0.47;
ISO 9974-1)
1.81
4.84
1.18
1.10
Ø0.974
W25x1.235x18x9g)
Type D spline shaft (DIN 5480)
R 0.02 max
0.26
0.73
0.47
M8 (metric thread)
0.63 deep
Ø3.1496/3.1478
0.31
Ø1.06
Ø0.9846/0.9841
1.10
3.54
5.47
5.79
(max)
0.83
1.65
1.38
Type K key shaft
Flange I
(ISO 3019/2)
0.14
2.866
4.02
1.77 Speed sensor
(optional)
2.09
25
0.41 (x4)Ø0.35 (x4)
Ø0.35 (x4)
3.74
CCW CW
Type I mounting flange (ISO 3019/2)
Key 8x7x35
22
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
F11-14
(SAE versions)
Catalogue HY17-8249/US
Installation dimensions
Ø0.94 (x2)
0.250
Ø1.06
Ø1.000/0.998
4.02
0.95
1.30
0.31
1.50
1.25
5.94
0.67
(x2)
6.21
(max)
5.75
29˚ (x4)
4.02
1.77 Speed sensor
(optional)
2.09
25˚
Ø0.57 (x2)
4.72
6.85 (max)
BA
R 10.24 (x2)
CCW CW
R 0.55 (x4)
(0.31)
3.98
1.81
5.24
1.18
Ø3.15
1.11
5
/
16
"-24 UNF-2B
(0.63 deep)
R 0.02
0.37
Ø4.000/3.998
Main ports 1
1
/
16
"-12 UN,
O-ring boss; SAE J514d
Drain port
9
/
16
" UNF;
O-ring boss; SAE J514d
Type S spline shaft
13 T,
16
/
32
DP
(SAE J498b; class 1,
30 involute spline,
flat root, side fit)
Drain port
9
/
16
" UNF,
O-ring boss; SAE J514d
Type T key shaft
Key
8x7x35
Type S mounting flange SAE 'B' ( SAE J744c)
23
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
F11-19
(SAE version)
Catalogue HY17-8249/US
Installation dimensions
3.46
0.43
2.48
Drain port D
9
/16"-18
Flange S
Key shaft T
SAE 'B-B'
(SAE J744c)
Key
1
/
4
"x
1
/
4
"x1
1
/
4
"
R 0.04
R 0.03
Ø1.11 min
Ø1.000
0.998
2.91
0.31
1.50
7.13 max
0.31
1.30
4.61
0.67
Spline shaft S (SAE J498b)
Approx.
center of
gravity
SAE 'B' (13T, 16/32 DP;
class 1, flat root, side fit)
2.13
Main port A
11/16"-12*
Main port B
11/16"-12*
Drain port C
9
/16"-18
Ø4.000
3.998
Ø6.93
max
1.14
0.38
6.10
30˚
Ø0.57 (x2)
Mounting flange S
SAE 'B' (SAE J744c)
0.63
min
5
/16"/24**
1.11
R 0.55
1.02
5.75
4.84
4.49 max
* O/ring boss (SAE J514d)
** UNC thread
24
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
F12-30, -40, -60, -80 and -110
(ISO versions)
Catalogue HY17-8249/US
Installation dimensions
A1
A1
A3
B3
K3
L3
C3
A2
G2
J2
N2
G3
H3
J3
F3
S2
See
table
D3 (thread)
Ø E3
P2
L2
Type I
flange
M2
D2
Ø E2
Ø F2
H2
(±0.02)
K2
Port C
1)
B2
C2
Port D Port A Port B
Ø D1 (x4)
B1
C1
T3
Type I mounting flange
(ISO 3019/2)
Type D (Z)
spline shaft
Type K (P)
key shaft
Port E (third drain port)
F12-110 barrel housing
(ISO/cartridge version)
NOTE:
Type Z has
no thread
Flushing
valve
(optional)
Speed
sensor
(optional)
1) Inspection/
drain port
Shown: F12-80
Q2
R2
25
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
Catalogue HY17-8249/US
Installation dimensions
Dim. F12-30 F12-40 F12-60 F12-80 F12-110
A1 3.48 4.46 4.46 5.01 5.57
B1 4.65 5.75 5.75 6.22 7.09
C1 4.65 5.59 5.67 6.10 7.09
D1 0.43 0.53 0.53 0.53 0.71
A2 3.94 4.33 4.92 5.32 5.71
B2 2.32 2.56 2.76 3.05 3.35
C2 0.98 1.02 0.87 1.26 1.50
D2 0.32 0.32 0.39 0.47 0.55
E2 1.30 1.65 1.65 2.05 2.26
F2 3.9370/ 4.9213/ 4.9213/ 5.5118/ 6.2992/
3.9349 4.9188 4.9188 5.5093 6.2967
G2 6.77 6.81 7.48 8.50 9.09
H2 1.00 1.28 1.28 1.28 1.59
J2
1)
1.97 2.36 2.36 2.76 3.23
J2
2)
1.97 - - - -
K2 2.16 2.05 2.13 2.76 2.61
L2 1.58 1.97 1.97 2.21 2.76
M2 0.20 0.20 0.20 0.28 0.24
N2 5.37 5.39 6.06 6.79 7.05
P2 0.32 0.32 0.32 0.32 0.32
Q2 1.10 1.10 1.30 1.42 1.61
R2
3)
1.38 1.38 1.61 1.77 1.97
R2
4)
1.69 1.38 - 1.61 -
S2*
3)
M12 M12 M12 M16 M16
x24 x24 x28 x36 x36
A3 4.80 5.28 5.67 6.10 6.69
B3 2.60 2.60 2.60 2.95 3.29
C3 0.937 0.937 0.937 1.094 1.250
D3* M12 M12 M12 M16 M16
E3 1.1817/ 1.1817/ 1.3787/ 1.5755/ 1.7724/
1.1812 1.1812 1.3780 1.5749 1.7717
F3 1.30 1.30 1.50 1.69 1.91
G3 5.37 5.39 6.06 6.79 7.05
H3 0.93 1.20 1.20 1.20 1.52
J3 0.95 0.95 1.10 1.42 1.42
K3 2.000 2.000 2.000 2.250 2.626
L3 0.71 0.79 0.79 0.79 0.87
S3 0.63 0.63 0.63 1.02 -
T3----2.68
* Metric thread
1) Key shaft type K 3) Spline shaft type D
2) " " " P 4) " " " Z.
Ports F12-30 F12-40 F12-60 F12-80 F12-110
A, B
3
/
4
"
3
/
4
"
3
/
4
"1"1
1
/
4
"
size
Screw M10 M10 M10 M12 M14
thread
1)
(0.79) (0.79) (0.79) (0.79) (1.02)
C, D M22 M22 M22 M22 M22
thread
2)
x1.5 x1.5 x1.5 x1.5 x1.5
E - - - - M22
thread
2)
x1.5
A, B: ISO 6162 1) Metric thread (depth in inches)
2) Metric thread x pitch in mm.
Spline shaft (DIN 5480; in mm)
= Max 5 100 psi (350 bar) operating pressure.
Metric key shaft (in mm)
Type K (standard) Type P (optional)
F12-30 30 dia. 25 dia.
-40 30 dia. -
-60 35 dia. -
-80 40 dia. -
-110 45 dia. -
Type D (standard) Type Z (optional)
F12-30 W30x2x14x9g W25x1.25x18x9g
-40 W32x2x14x9g W30x2x14x9g
-60 W35x2x16x9g W32x2x14x9g
-80 W40x2x18x9g W35x2x16x9g
-110 W45x2x21x9g -
26
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
F12-30, -40, -60, -80 and -110
(Cartridge versions)
Catalogue HY17-8249/US
Installation dimensions
A4
B4
A5
G5
R5
Q5
Ø V5
Ø F5
See table
Type C
spline
shaft
H5
(±0.2)
K5
S5
T5
B5
C5
N5
Ø M6
Ø N6
Ø P6
L6
O-ring
(included)
A6
B6
C6
K6
G6
H6
Q6
R6
P5
Port DPort BPort A
Port C
1)
C4
T6
E4
Ø D4
(x2)
40 (-30, -40, -60, -110)
43 (-80)
Flushing
valve
(optional)
Speed
sensor
(optional)
Type C mounting flange
1) Inspection/
drain port
Port E (third drain port)
F12-110 barrel housing
(ISO/cartridge version)
Shown: F12-80
Ø E5
J5
D5
L5
M5
Type K (X) key shaft
XX˚
27
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
Catalogue HY17-8249/US
Installation dimensions
O-ring dimensions (in mm)
F12-30 127x4
-40 150x4
-60 150x4
-80 180x4
-110 190x4
Ports F12-30 F12-40 F12-60 F12-80 F12-110
A, B
3
/
4
"
3
/
4
"
3
/
4
"1"1
1
/
4
"
size
Screw M10 M10 M10 M12 M14
thread
3)
(0.79) (0.79) (0.79) (0.87) (1.02)
C M14 M14 M14 M14 M14
thread
4)
x1.5 x1.5 x1.5 x1.5 x1.5
D, E M18 M18 M22 M22 M22
thread
4)
x1.5 x1.5 x1.5 x1.5 x1.5
A, B: ISO 6162 3) Metric thread (depth in inches)
4) Metric thread x pitch in mm.
Dim. F12-30 F12-40 F12-60 F12-80 F12-110
A4 6.30 7.87 7.87 8.82 9.84
B4 5.51 6.46 6.46 7.72 8.11
C4 7.40 9.25 9.25 10.24 11.26
D4 0.55 0.71 0.71 0.87 0.87
E4 3.03 3.74 3.74 4.33 4.57
A5 3.94 4.33 4.92 5.31 5.71
B5 2.32 2.56 2.76 3.05 3.35
C5 0.98 1.02 0.87 1.26 1.50
D5 0.31
1)
2)
0.39 0.47 0.55
E5 1.1817/
1)
2)
1.3787/ 1.5755/ 1.7724/
1.1812 1.3780 1.5749 1.7717
F5 5.3150/ 6.2992/ 6.2992/ 7.4803/ 7.8740/
5.3125 6.2967 6.2967 7.4775 7.8712
G5 5.00 5.24 5.75 6.18 6.89
H5 3.50 3.63 3.63 4.35 4.83
J5 1.97 2.36 2.36 2.76 -
K5 0.55 0.63 0.59 0.59 0.59
L5 1.57 1.97 1.97 2.20 -
M5 0.20 0.20 0.20 0.28 -
N5 3.58 3.82 4.33 4.49 4.84
P5 0.87 1.18 1.22 1.57 1.57
Q5 1.10 1.10 1.10 1.46 1.46
R5 1.38 1.38 1.38 1.77 1.77
S5 2.78 2.83 2.99 3.58 3.77
T5 0.59 0.59 0.59 0.59 0.59
V5 1.30 1.38 1.38 1.77 1.77
A6 4.80 5.28 5.67 6.10 6.69
B6 2.60 2.60 2.60 2.95 3.27
C6 0.937 0.937 0.937 1.094 1.250
G6 3.60 3.82 4.33 4.49 4.84
H6 2.74 2.80 2.91 3.52 3.69
K6 2.000 2.000 2.000 2.250 2.626
L6 0.63 0.71 0.71 0.79 0.79
M6 3.62 4.53 4.53 5.12 5.51
N6 4.33 5.00 5.31 6.06 6.30
P6 5.047 6.031 6.031 7.213 7.606
Q6 0.20 0.20 0.20 0.20 0.20
R6 0.20 0.20 0.20 0.20 0.20
T6----2.68
1) Key shaft type K: D5 - 0.31; E5 - 1.1817/1.1812
2) Key shaft type X: D5 - 0.39; E5 - 1.3787/1.3780
Spline shaft (DIN 5480; in mm)
Type C (standard)
F12-30 W30x2x14x9g
-40 W30x2x14x9g
-60 W30x2x14x9g
-80 W40x2x18x9g
-110 W40x2x18x9g
Metric key shaft (in mm)
Type K (std) Type X (opt.)
F12-30 30 dia.
-40 - 35 dia.
-60 35 dia.
-80 40 dia.
-110
28
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
F12-30, -40, -60, -80 and -110
(SAE versions with 4 bolt flange)
Catalogue HY17-8249/US
Installation dimensions
A7
A7
Ø D7 (x4)
B7
Type S (SAE 4 bolt) mounting flange
C7
T9
Port E (third drain port)
F12-110 barrel housing
(SAE version)
A8
G8
J8
N8
L8
Type S
flange
M8
D8
Ø E8
Ø F8
H8
K8
Port C
1)
B8
C8
Port D
Type T
key shaft
Flushing
valve
(optional)
Speed
sensor
(optional)
1) Inspection/
drain port
A9
B9
K9
L9
C9
G9
H9
J9
F9
R8
Q8
See
table
D9 (thread)
Ø E9
Port A Port B
Type S (U)
spline shaft
Shown: F12-80 with 4 bolt flange
29
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
Catalogue HY17-8249/US
Installation dimensions
Dim. F12-30 F12-40 F12-60 F12-80 F12-110
A7 3.54 4.51 4.51 4.51 6.36
B7 4.65 5.83 5.83 6.10 8.03
C7 4.65 5.67 5.67 6.10 7.87
D7 0.55 0.55 0.55 0.55 0.83
A8 3.94 4.33 4.92 5.31 5.71
B8 2.32 2.56 2.76 3.05 3.35
C8 0.98 1.02 0.87 1.26 1.50
D8 0.25 0.31 0.31 0.38 0.44
E8 1.30 1.65 1.65 2.05 2.26
F8 4.000/ 5.000/ 5.000/ 5.000/ 6.000/
3.998 4.998 4.998 4.998 5.998
G8 7.46 7.76 8.43 9.45 10.39
H8 0.31 0.31 0.31 0.31 0.31
J8 1.50 1.89 1.89 2.13 2.64
K8 2.83 2.99 3.11 3.74 3.90
L8 1.25 1.50 1.50 1.75 2.13
M8 0.10 0.16 0.16 0.16 0.29
N8 6.04 6.34 7.02 7.76 8.35
Q8
1)
0.91 0.91 0.91 0.98 1.34
Q8
2)
---0.91-
R8
1)
1.30 1.89 1.89 2.13 2.63
R8
2)
---1.88-
A9 4.80 5.28 5.67 6.10 6.69
B9 2.60 2.60 2.60 2.95 3.27
C9 0.937 0.937 0.937 1.094 1.250
D9*
5
/
16
"-24
3
/
8
"-24
3
/
8
"-24
1
/
2
"-20
5
/
8
"-18
E9 1.000/ 1.250/ 1.250/ 1.500/ 1.750/
0.998 1.248 1.248 1.498 1.748
F9 1.11 1.39 1.39 1.67 1.94
G9 6.06 6.34 7.02 7.76 8.35
H9 0.38 0.50 0.50 0.50 0.50
J9 0.63 0.75 0.75 1.02 1.26
K9 2.000 2.000 2.000 2.250 2.626
L9 0.71 0.79 0.79 0.79 0.87
T9----2.68
* UNF-2B thread
1) Spline shaft type S
2) " " " U
Main ports A and B, type U (optional)
F12-110 1
5
/
8
" - 12 UN
O-ring ports according to SAE J514d
Ports F12-30 F12-40 F12-60 F12-80 F12-110
A, B
3
/
4
"
3
/
4
"
3
/
4
"1"1
1
/
4
"
size
Screw
3
/
8
"-16
3
/
8
"-16
3
/
8
"-16
7
/
16
"-14
1
/
2
"-13
thread
3)
(0.87) (0.79) (0.87) (1.06) (0.98)
C
7
/
8
"-14
7
/
8
"-14
7
/
8
"-14
7
/
8
"-14 1
1
/
16
"-12
thread
D
3
/
4
"-16
3
/
4
"-16
7
/
8
"-14
7
/
8
"-14 1
1
/
16
"-12
thread
E- - - -1
1
/
16
"-12
thread
A, B: ISO 6162; C, D, E: O-ring boss (SAE J514)
3) UN thread (depth in inches)
Key shaft (SAE J744)
T (standard) X (optional)
F12-30 SAE 'B-B' -
(1"/ 25.4 mm)
-40 SAE 'C' -
(1
1
/
4
"/ 31.75 mm)
-60 SAE 'C' -
(1
1
/
4
"/ 31.75 mm)
-80 SAE 'C-C' SAE ’D’
(1
1
/
2
"/ 38.1 mm) (1
3
/
4
"/ 44.45 mm)
-110 SAE 'D' -
(1
3
/
4
"/ 44.45 mm)
Mounting flange (SAE J744)
S (standard) X (optional)
F12-30 SAE 'B', 4 bolt -
-40 SAE 'C', " -
-60 SAE 'C', " -
-80 SAE 'C', " SAE ’D’, 4 bolt
-110 SAE 'D', " -
Spline shaft (SAE J498b, class 1, flat root, side fit)
S (standard) U (opt.) X (optional)
F12-30 SAE 'B' - -
13T, 16/32 DP
-40 SAE 'C' 14T, - -
12/24 DP
-60 SAE 'C' 14T, - -
12/24 DP
-80 SAE 'C-C' SAE 'C' SAE 'D'
17T, 12/24 DP 14T,12/24DP 13T, 8/16 DP
-110 SAE 'D' - -
13T, 8/16 DP
= Max 5100 psi (350 bar) operating pressure.
30
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
F12-30, -40, and -60
(SAE versions with 2 bolt flange)
Catalogue HY17-8249/US
Installation dimensions
Ø D10
(x2)
A10
B10
G11
J11
D11
A11 B11
C11
N11
L12
A12
B12
C12
G12
Port A Port B Port D
H12
K12
J12
F12
D12 (thread)
Type T
flange
Ø E12
L11
M11
Ø E11
Ø F11
K11
H11
Port C
(inspection/
drain port)
Type T
key shaft
R11
Q11
See
table
Type S spline shaft
F10
E10 R
C10 R
Flushing
valve
(optional)
Speed
sensor
(optional)
Shown: F12-60 with 2 bolt flange
31
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
Catalogue HY17-8249/US
Installation dimensions
Ports F12-30 F12-40 F12-60
A, B size
3
/
4
"
3
/
4
"
3
/
4
"
Screw
3
/
8
"-16
3
/
8
"-16
3
/
8
"-16
thread
1)
(0.87) (0.79) (0.87)
C thread
3
/
4
"-16
3
/
4
"-16
7
/
8
"-14
D thread
3
/
4
"-16
3
/
4
"-16
7
/
8
"-14
A, B (main ports): SAE J518c (6000 psi)
C, D (drain ports): O-ring boss (SAE J514)
1) UN thread (depth in inches).
Spline shaft(SAE J498b, class 1, flat root, side fit)
Type S
F12-30 SAE 'B'
13 T; 16/32 DP
-40 SAE 'C'
14 T; 12/24 DP
-60 SAE 'C'
14 T; 12/24 DP
Mounting flange (SAE J744)
Type T
F12-30 SAE 'B', 2 bolt
-40 SAE 'C', 2 bolt
-60 SAE 'C', 2 bolt
Key shaft (SAE J744)
Type T
F12-30 1" dia. SAE 'B-B'
-40 1
1
/
4
" dia. SAE 'C'
-60 1
1
/
4
" dia. SAE 'C'
Dim. F12-30 F12-40 F12-60
A10 5.75 7.13 7.13
B10 6.93 8.46 8.46
C10 2.48 2.91 2.91
D10 0.57 0.69 0.69
E10 0.39 0.63 0.63
F10 0.39 0.61 0.61
A11 3.94 4.33 4.92
B11 2.32 2.56 2.76
C11 0.98 1.02 0.87
D11 0.25 0.31 0.31
E11 1.30 1.65 1.65
F11 4.000/ 5.000/ 5.000/
3.998 4.998 4.998
G11 7.46 7.76 8.43
H11 0.31 0.31 0.31
J11 1.50 1.89 1.89
K11 2.80 3.03 3.21
L11 1.25 1.50 1.50
M11 0.10 0.16 0.16
N11 6.06 6.34 7.03
Q11 1.02 1.06 1.06
R11 1.30 1.89 1.89
A12 4.80 5.28 5.67
B12 2.60 2.60 2.60
C12 0.937 0.937 0.937
D12
* 5
/
16
"-24
3
/
8
"-24
3
/
8
"-24
E12 1.000/ 1.250/ 1.250/
0.998 1.248 1.248
F12 1.11 1.39 1.39
G12 6.06 6.34 7.03
H12 0.38 0.50 0.50
J12 0.63 0.75 0.75
K12 2.000 2.000 2.000
L12 0.71 0.79 0.79
* UNF-2B thread
Main ports A and B, type U (optional)
F12-30 1
1
/
16
" - 12 UN
-40 1
5
/
16
" - 12 UN
-60 1
5
/
16
" - 12 UN
O-ring ports according to SAE J514d
= Max 350 bar operating pressure.
32
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
F11-150
(CETOP version)
Catalogue HY17-8249/US
Installation dimensions
4.29
10
0.98
6.26
12.09
6.77 4.65
0.71
Drain port D
BSP 3/4"
Ø2.24
min
Ø7.8740
7.8712
Ø9.84
Ø0.87(x4)
9.29 max
9.29
Approx.
center of
gravity
R 0.04
14x9x70
(0.55x0.35x2.76;
metric key)
R 0.03
Flange C
Type C mounting flange
8.74 max
3.98
3.35
2.11
3.125
1.18
9.84
1.97
3.23
1.81
ØM16(x8)*
1.44
Main port A
1 1/2" **
Main port B
1 1/2" **
Drain port C
BSP 3/4"
Ø1.9692/
1.9686
M16
(metric thread)
Type K key shaft
1.97
1.97
W45x2x21x9g
(metric spline)
Spline shaft D (DIN 5480)
* Metric thread, deep1.4
** 6000 psi flange (SAE J581c)
1.18
M16
(metric thread)
33
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
F11-150
(SAE version)
Catalogue HY17-8249/US
Installation dimensions
8.74 max
3.98
3.35
1.94
3.13
1.18
11.69
6.18
0.94
8.11
13.98
0.31
2.63
0.50
ØM16* (x8)
1.437
6.77 4.65
0.71
Main port A
1 1/2" **
Main port B
1 1/2" **
Drain port C
BSP 3/4"
Drain port D
BSP 3/4"
Ø1.750/
1.748
Ø2.24
min
Ø6.000/
5.998
7
/
16
"x
7
/
16
"x2
1
/
8
"
(key)
Key shaft T
SAE 'D'
(SAE J744c)
Ø0.83 (x4)
8.43 max
7.56
6.362
Approx.
center of
gravity
R 0.04
R 0.03
0.31
2.63
SAE 'D'; 13T, 8/16 DP;
class 1, flat root, side fit
Spline shaft S (SAE J498b)
Mounting flange S
SAE 'D' (SAE J744c)
Flange S
* Metric thread, deep1.4
** 6000 psi flange (SAE J581c)
34
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
F11-250
(SAE version)
Catalogue HY17-8249/US
Installation dimensions
9.13
3.98
5.55
3.125
M16 (metric
thread)
13.23
6.36
8.11
max
0.50
1.22
R 0.03
M16 (x8)
1.4 deep
(metric
thread)
1.437
7.76 4.65
0.94
1.06
Main port A
1 1/2" *
Main port B
1 1/2" *
Drain port C
BSP 3/4"
Drain port D
BSP 3/4"
2.11
Ø6.000/
5.998
6.36
8.11 max
Ø0.83
(x4)
Ø1.9692/
1.9686
Type K key shaft
(metric; not SAE)
14x9x70
(0.55x0.35x2.76;
metric key)
Ø2.24
min
Ø1.54
(x2)
7.09
15.55
3.23
0.31
8.50
Approx.
center of
gravity
R 0.03
0.31
2.63
1.38
Mounting flange S
SAE 'D' (SAE J744c)
Spline shaft F (SAE J498b)
SAE F; 15T, 8/16 DP;
class 1, flat root, side fi
t
Optional:
SAE S; 13T, 8/16 DP
* 6000 psi flange (SAE J581c)
35
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
F11 with built-in
make-up valve
Saw bar supported
directly on the
motor flange
Feed
cylinder
Chain spur gear mounted
directly on the shaft
Saw
chain
Protective
cover
Saw
bar
Port A Port B
Port G
Only for F11-10, -19
(for make-up flow
if required)
Port C/D
Chain saw installation (example; F11-10 shown)
F11 fan motors
Frame sizes -10, -14 and -19 are also available as 'fan
motors' with a built-in check valve (refer to the sche-
matic below) and CETOP mounting flange. Just like the
saw motor, the fan motor can be operated at very high
speeds without reliability problems.The fan is usually
installed directly on the motor shaft without additional
bearing support.
Additional information (available versions, ordering
codes, installation dimensions, etc.) is available in
publication 'F11 Fan Motors'
(catalogue 9129 8247-02).
Fan motor (F11-10 shown).
Fan motor schematic (left hand rotation shown).
F11 saw motors
Series F11 motors have proven extremely reliable in
demanding applications such as bar (chain) saws.
Primarily due to the 40° bent-axis design, spherical
pistons (with laminated piston rings) and gear synchro-
nization, very high speeds are permissible. Not even
low temperatures at start-up affect reliability.
To further enhance the saw function and, at the same
time, reduce weight, cost and installation dimensions, a
specific saw motor has been developed (frame sizes
-10, -14 and -19; refer to the illustration to the right)
which is specifically dedicated to bar saws. The motor
allows the saw bar bearings to be mounted directly on
the motor housing, and the spur gear installs on the
motor shaft without any additional bearings.
For more detailed information (available versions,
ordering codes, installation dimensions, etc.), refer to
'F11 Saw Motors' (catalogue 9129 8245-02).
Catalogue HY17-8249/US
Technical information
Built-in
make-up
valve
Mounting
flange C
(CETOP)
Key shaft
(CETOP)
Port GMain port B
Main port A
Drain port C
Alternative
drain port D
36
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
Integrated flushing valve
(F12-30, -40, -60, -80)
Nozzle
(optional)
Port A
Port B
Built-in
flushing
valve
Nozzle
(optional)
FV13 flushing
valve block
Nozzle
(optional)
Port A
Port B
Nozzle (optional)
FV13 flushing
valve block
F12 accessory valve blocks
Type FV13 flushing valve (for F12-110)
A separate flushing valve block is available for the
F12-110. It has the same function as the integrated
valve for the other F12 frame sizes (above).
The valve block mounts between the motor port flange
and the split flanges as shown to the right.
An optional nozzle can be installed in the valve block
drain port.
Ordering code: FV13
NOTE: Additional information is available in
publication ’Mobile motor/pump accessories’
(catalogue HY17-8258/UK).
F12 integrated flushing valve
(F12-30, -40, -60 and -80)
Series F12 (except F12-110; refer to the FV13 flushing
valve block below) is available with an integrated
flushing valve which provides the rotating parts with an
additional cooling flow, required when operating at high
speeds and power levels.
In a hydrostatic transmission, the valve also ensures
that part of the main circuit fluid is being removed and
replaced by cool, filtered fluid from the charge pump.
The flow is limited by a suitably sized nozzle that
installes below a plug in the motor port flange.
NOTE: Ordering code, available nozzles and
other information is provided in publica-
tion ’Mobile motor/pump accessories’
(catalogue HY17-8258/UK).
Catalogue HY17-8249/US
Technical information
37
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
BT brake
valve block
BT brake
valve block
F12-
motor
Brake release valve
flushing valve etc.
Port BR
(brake
release)
Port A
Port B
Port S
(make-up)
Port G
SR valve block
Type SR pressure relief/make-up valve
The SR pressure relief/make-up valve block for series
F12 motors is designed to protect the motor from high
pressure spikes as well as provide an excellent make-
up function to help prevent motor cavitation (when port
G is pressurized).
The valve block mounts between the motor port flange
and the split flanges (as shown to the right).
The SR block is available in three sizes:
- SR11 (
3
/
4
") for F12-30, -40, -60
- SR12 (1") for F12-80
- SR13 (1
1
/
4
") for F12-110
NOTE: - For additional information such as
pressure settings and installation
dimensions, refer to publication
’Mobile motor/pump accessories’
(catalogue HY17-8258/UK).
- To obtain a combined cross-over relief/
make-up and flushing function on the
F12-110, the SR13 and FV13 valve
blocks can be stacked (with the flushing
valve block mounted next to the motor).
Type BT brake valve
When a motor (in an open loop system) is used in a
hydrostatic vehicle transmission, the motor may
operate faster than what corresponds to the available
pump flow (e.g. in a steep downhill); this can lead to
motor cavitation and loss of braking power.
The BT brake valve prevents cavitation by throttling
the return flow from the motor as soon as the pressure
level in the inlet port decreases to approximately 35
bar. At the same time, motor braking is provided when
the pump flow decreases or is shut off.
The BT brake valve can be supplied with various
optional functions such as a mechanical brake release
valve and a flushing valve.
The valve block is very compact and installs between
the motor port flange and the split flanges
(refer to the illustration).
The BT valve block is available in two sizes:
- BT21 (
3
/
4
") for F12-30, -40, -60
- BT22 (1") for F12-80
NOTE: Detailed information on the BT valve is
provided in publication
’Mobile motor/pump accessories’
(catalogue HY17-8258/UK).
Catalogue HY17-8249/US
Technical information
Port A
Port B
Port G SR valve block F12-motor
Port L
38
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
SV pressure relief
valve block
SV valve block
Port A
Port B
(Port L)
Speed
sensor
Type SV pressure relief valve
The SV pressure relief valve for series F12 motors
protects the motor and the corresponding main hy-
draulic lines from pressure spikes. Like the SR valve
block (page 31), it has integrated cartridge type
pressure relief valves and mounts between the motor
port flange and the split flanges as shown to the right.
The design of the relief valves permits a limited make-
up flow (when port L is pressurized).
The SV valve block is available in three sizes:
- SV11 (
3
/
4
") for F12-30, -40, -60
- SV12 (1") for F12-80
- SV13 (1
1
/
4
") for F12-110
NOTE: - Detailed information on available
pressure settings, installation dimen-
sions, etc. is provided in publication
’Mobile motor/pump accessories’
(catalogue HY17-8258/UK).
- On the F12-110, the FV13 flushing valve
block (page 36) can be mounted between
the SV13 block and the motor port flange
to obtain a combined pressure relief and
flushing function.
Speed sensor
A speed sensor kit is available for series F11/F12.
A ferrostat differential (Hall-effect) sensor installs in a
separate, threaded hole in the F11/F12 bearing
housing.
On F12 the speed sensor is directed towards the ring
gear.On F11 the speed sensor is directed towards the
pistons. The speed sensor outputs a square wave
signal within a fequency range of 5 Hz to 20 kHz.
NOTE: - The motor bearing housing must be
prepared for the speed pick-up;
refer to the F11/F12 ordering codes
(pages 7-12).
- On F11 the pistons position must be
known before mounting.
- Additional information is provided in
’Mobile motor/pump accessories’
(catalogue HY17-8258/UK).
- The speed sensor is also shown in the
illustrations on pages 19, 21, 22, 24, 26
and 28.
Catalogue HY17-8249/US
Technical information
F12 with speed sensor.
F11-14 with speed sensor.
Speed
sensor
39
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
L
2"
hose
Suction
fitting
(Split-flange
half)
(Mounting
screw)
(O-ring)
Suction fittings
To minimize the risk for cavitation when operating the
F12 as a pump, we recommend using our suction
fittings; all take 2" hoses.
Part no. SAE size For L [inch]
379 4070
3
/
4
" F12-30 3.94
F12-40
F12-60
370 4095 1" F12-80 3.94
370 3916 1
1
/
4
" F12-110 4.02
The suction fittings are designed for use with standard
SAE or metric split-flange halves as shown.
O-ring and mounting screw sizes are listed below.
SAE O-ring Screw size
size dimension [mm] SAE Metric
3
/
4
" 30.0x3.53
3
/
8
"-16x1.50 M10x35
1" 32.9x3.53
7
/
16
"-14x1.50 M12x40
1
1
/
4
" 37.7x3.53
1
/
2
"-13x1.75 M14x45
Suction fitting kits
Suction fitting kits are available for the F12 ISO and
Cartridge versions. A kit consists of a suction fitting
(shown above), two split-flange halves, an
O-ring and four mounting screws.
Part no. SAE size For Screw size
379 4421
3
/
4
" F12-30/-40/-60 M10x35
370 4098 1" F12-80 M12x40
370 3926 1
1
/
4
" F12-110 M14x45
Split-flange kits
Separate metric split-flange kits, consisting of two split-
flange halves and four mounting screws for use on the
F12 ISO and cartridge versions, are also available.
Part no. SAE size For Screw size
379 4405
3
/
4
" F12-30/-40/-60 M10x35
370 4329 1" F12-80 M12x40
370 4330 1
1
/
4
" F12-110 M14x45
F12 main port suction fittings
(Split-flange
half)
(Mounting
screw)
Catalogue HY17-8249/US
Technical information
40
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
Clockwise rotation
Port A Port B
Counter
clockwise
rotation
Direction of rotation
The M and H versions of series F11, and the M version
of series F12, are bi-directional.
The L and R pump versions are uni-directional, allow-
ing higher selfpriming speeds
(refer to page 14).
The illustration to the right shows direction of flow
versus shaft rotation. In a motor application, the shaft
turns clockwise when port B (black arrow) is pressu-
rized, and counter clockwise when port A (open arrow)
is pressurized.
In a pump application where the shaft turns clock-wise,
port B is the inlet port and should be connected to tank;
when the shaft turns counter clockwise, port A is the
inlet port.
Hydraulic fluids
Ratings and performance data for series F11/F12 are
based on operating with good quality, contamination-
free, petroleum-based fluids.
Hydraulic fluids type HLP (DIN 51524), automatic
transmission fluids type A, or API CD engine oils can
be used.
Fire resistant fluids (when used under modified operat-
ing conditions) and synthetic fluids may also be suit-
able.
For additional information, refer to Hydraulic Marketing
IS data base:
- Hydraulic fluid specifications
- Fire resistant fluids.
Operating temperature
The following temperatures should not be exceeded
(type H and N shaft seals):
Drain fluid: 195 °F
(90 °C)
Viton shaft seals (F11 type E, F12 type V) can be used
to 240 °F
(115 °C)
drain fluid temperature.
NOTE: The temperature should be measured at
the utilized drain port.
Continuous operation may require case flushing in
order to meet the viscosity and temperature limitations.
The following table shows operating speeds, above
which flushing is usually required, as well as suggested
flow through the case.
NOTE:
When operating the F11/F12 as a pump above the
selfpriming speed (valid for both the pump and
motor versions), the inlet must be sufficiently
pressurized. Increased noise and deteriorating
performance may otherwise be experienced.
For further information refer to ’Selfpriming speed
and required inlet pressure’ on page 6.
Catalogue HY17-8249/US
Installation information
Series F12
Frame size Speed [rpm] Flow [l/min] Flow [gpm]
F12-30 3500 4–8 1.0–2.1
F12-40 3000 5–10 1.3–2.6
F12-60 3000 7–14 1.9–3.7
F12-80 2500 8–16 2.1–4.2
F12-110 2300 9–18 2.4–4.8
Series F11
Frame size Speed [rpm] Flow [l/min] Flow [gpm]
F11-5 5500 1–2 0.25-0.5
F11-10 4500 2–3 0.5-0.8
F11-14 4500 23 0.5-0.8
F11-19 4000 2–4 0.5-1.0
F11-150 2200 10–20 2.6-5.2
F11-250 1800 12–22 3.2-5.8
41
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
Catalogue HY17-8249/US
Installation information
Shaft seal H/V
N
H/V
N
H/V
N
H/V
N
H/V
N
F12-30 205
30
100
20
80
15
65
10
50 -
F12-40 175
30
85
15
65
10
50
5
--
F12-60 175
30
85
15
65
10
50
5
--
F12-80 145
30
70
10
60
5
-- --
F12-110 140
30
65
10
-- -- --
Max recommended case pressure versus shaft speed -
F12 seal types H or V, and N
Series F12
Shaft seal H/V
N/E
H/V
N/E
H/V
N/E
H/V
N/E
H/V
N/E
H/V
N/E
H/V
N/E
H/V
N/E
H/V
N/E
H/V
N/E
F11-5 20
2.2
13
1.9
10
1.6
8
1.3
6.5
0.9
5
0.6
4.2
0.5
4
0.3
3.5
0.2
3
0
F11-10 20
2.2
11.5
1.8
8.5
1.2
7
1.0
5.5
0.7
4
0.5
3.8
0.4
3.5
0.2 3.0 0 - -
F11-14 19
2.2
9.5
1.5
7
1.0
5.5
0.8
4.5
0.5
3.5
0.4
3.0
0.2
2.5
0
-- --
F11-19 19
2.2
9.5
1.4
7
0.9
5.5
0.6
4.5
0.4
3.5
0.3
3.0
0-- ----
F11-150 9.5
2.2
4.5
0.6-- -- -- -- -- -- -- --
F11-250 9.5
-
4.5
-----------------
Max case pressure [psi]
versus shaft speed [rpm]
S
peed
1500 3000 4000 5000 6000 8000 9000 10000 11000 12000
Max recommended case pressure versus shaft speed - F11 seal types H or V and N or E.
Max case pressure [psi] vs. shaft speed [rpm]
S
peed
1500 3000 4000 5000 6000
Series F11
Viscosity
The ideal operating range is75 to 150 SUS
(15 to 30 mm
2
/s).
At operating temperature, the viscosity (of the drain
fluid) should be kept above 46 SUS (8 mm
2
/s [cSt]).
At start-up, the viscosity should not exceed
5 000 SUS (1000 mm
2
/s)
Filtration
To obtain the highest service life of the F11/F12,
the fluid cleanliness should meet or exceed
ISO code 18/13 (ISO 4406).
During normal operating conditions, a 10 µm
(absolute) filter is recommended.
Case pressure
The tables below show the highest recommended
case pressure as a function of shaft speed.
‘Nominal’ shaft seal life can be expected at a certain
speed and the corresponding max case pressure. Seal
life will be shorter, however, at unfavourable operating
conditions (high temperature, low oil viscosity,
contaminated oil).
42
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
Port C
Port E
(F12-110)
Port D
Drain flow
Flushing flow
(when required)
Spring loaded
check valve
Drain flow
Case drain connections
Series F11/F12 have two drain ports, C and D, while
F12-110 has an additional port, E.
The uppermost drain port (such as port C in the illus-
tration below) should always be utilized.
In mounting positions such as 'shaft up' (below)
a spring loaded check valve should be installed in the
drain line in order to insure a sufficiently high oil level
in the case.
Preferably, the drain line should be connected directly
to the reservoir.
Before start-up
Make sure the F11/F12 case as well as the entire
hydraulic system is filled with a recommended fluid.
The internal leakage, especially at low operating
pressures, is
not
sufficient to provide lubrication at
start-up.
NOTE:
- To avoid cavitation and obtain a low noise level as
well as reduced heat generation, tubes, hoses and
fittings must be adequately dimensioned.
- Preferably, the suction line flow speed should be
1.5 to 3.5 fps (0.5 to 1 m/s), and pressure line flow
speeds 10 to 16 fps (3 to 5 m/s).
- For series F12, suitable suction fittings are available
(refer to page 39).
Catalogue HY17-8249/US
Installation information
43
Parker Hannifin
Mobile Controls Division
Trollhättan, Sweden
Hydraulic motor/pump
Series F11/F12
Offer of Sale
Please contact your Parker representation for a detailed ”Offer of Sale”.
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED
HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide
product and/or system options for further investigation by users having technical expertise. It is important that you analyze all
aspects of your application, including consequences of any failure, and review the information concerning the product or
system in the current product catalogue. Due to the variety of operating conditions and applications for these products or
systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and
systems and assuring that all performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are
subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.
WARNING
!
Catalogue HY17-8249/US
General information
Parker Hannifin is the world’s premier supplier of motion and control systems
and solutions, with sales and manufacturing facilities throughout the world.
For product information and details of your nearest Parker sales office, visit us
at www.parker.com or call free on 1-800-272-7537 (North America).
Hydraulics Group
Sales Offices
Catalogue HY17-8249/US
2M 03/04 RT
© Copyright 2004
Parker Hannifin Corporation
All rights reserved.
North America
USA, Canada
100 Parker Drive
Otsego, MI 49078
USA
Tel: +1 269-694-9411
Fax: +1 269-694-4638
Mexico
Via de Ferrocarril a Matamoros #730
Apodaca, N.L.
Mexico
C.P. 6 6 6 0 0
Tel: +52 81 56 6000
Fax: +52 81 56 6076
Latin America
Pan American Division
7400 N.W. 19th Street
Suite A
Miami, FL 33126
USA
Tel: +305 470 8800
Fax: +305 470 8808
Argentina
Stephenson 2711
(1667) Tortuguitas–Malvinas Argentinas
Pcia. de Buenos Aires
Argentina
Tel: +54 11 4752 4129
Fax: +54 11 4752 3704
Brazil
Av. Lucas Nogueira Garcez
2181 Jacarei, SP Brazil 12300-000
Brazil
Tel: +55 12 354 5100
Fax: +55 12 354 5262
Chile
Av. Americo Vespucio 2760-C,
Conchali
Santiago
Chile
Tel: +56 2 623 1216
Fax: +56 2 623 1421
Venezuela
Av. Principal de Boleita Norte con Calle Miraima,
Edf. Draza, Planta Baja
Caracas 1070
Venezuela
Tel: +58 212 238-5422
Fax: +58 212 239-2272