Hydraulics
A9
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio 44035 USA
Catalog HY14-2550/US
D_1FW-D_1FT.p65, dd, an
Proportional Directional Control Valves
A
General Description
The D*1FW/D*1FT series two-stage pilot operated
proportional directional control solenoid valves are
available with or without integrated control electronics.
Valves are available in sizes NG10 (CETOP 5), NG16
(CETOP 7), NG25 (CETOP 8) and NG32 (CETOP 10).
Typical applications include reproducible control of
actuator speed in rapid/slow speed profiling, and
smooth acceleration and deceleration performance.
Features
•
Standard DIN/ISO/CETOP/NFPA interfaces.
•
Optional integrated control electronics with ramp
adjustment.
•
Low leakage.
•
Progressive flow characteristics for improved low flow
resolution.
•
Spring centered main stage spool.
•
Wide selecton of spool options and flow capacity.
•
2:1 ratio spool options.
Technical Information Series D*1FW and D*1FT
Series D*1FW without integrated electronics
Series D*1FT with integrated electronics
Supply Voltage 14.5 to 30 VDC
Current 3 amps
Command Signal
(impedance) 0 ± 10 VDC (100K)
(select by ordering code) 0 ± 20 mA (500 ohms)
Command Polarity Pin ‘D’ more positive
than ‘E’; flow P to B
Ramp Time Adjustment 0 to 3 seconds
Environmental Protection
Class NEMA 1 (IP54)
Mating Connector
(order separately) (7-pin CE) Part #5004072
Solenoid (order code “L”)
Nominal Resistance 2.2 ohms
Nominal Current 2.5 amps
Nominal Voltage 6 volts
Solenoid (order code “X”)
1)
Nominal Resistance 9.8 ohms
Nominal Current 1.3 amps
Nominal Voltage 16 volts
Environmental Protection Class NEMA 1 (IP54)
Mating Connectors Part # 692914 (black)
Solenoid (DIN 4350) Part # 692915 (gray)
(optionally included with valve)
1) For use with 24 volt based electronic driver cards.
Repeatability %<2
Operating Pressure
Port P, A, B Bar (PSI) 345 (5000) max.
Port P, internal pilot 20 (290) min.
Port T, internal drain 10 (150) max.
Port T, external drain 345 (5000) max.
Port Y, pilot drain 10 (150) max.
Port X, external pilot 20-345 (290-5000)
Specifications
Interface DIN (NFPA/ISO/CETOP) NG10 (05) NG16 (07) NG25 (08) NG32 (10)
Flow Rating @10 Bar (150 PSI) ∆p (P→A, B→T)
(Spool options up to) LPM (GPM) 75 (20) 200 (53) 400 (106) 1000 (264)
Pilot Flow — Continuous LPM (GPM) 1.2 (0.3) 1.2 (0.3) 1.2 (0.3) 1.2 (0.3)
Step Response ms 60 75 100 200
Weight kg. (lbs.) 7.1 (16) 10.8 (24) 19 (42) 62 (137)
Hysteresis %<5
Fluid Cleanliness Level ISO Class 16/13
Fluid Viscosity,
Recommended 80 – 1000 SSU
Fluid Temperature, 0°C to +60°C
Recommended (+32°F to +140°F)
Ambient Operating -20°C to +60°C
Temperature (-4°F to +140°F)