Proportional Directional Control Valves
Catalog HY14-2550/US
A158
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Series D*1FP
A
General
Size NG10 (CETOP 5) NG16 (CETOP 7) NG25 (CETOP 8) NG32 (CETOP 10)
Mounting
DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting Position
Unrestricted
Ambient Temperature Range
-20°C to +50°C (-4°F to +122°F)
Hydraulic
Maximum Operating Pressure
Internal Pilot Drain P, A, B, X: 350 Bar (5075 PSI); T, Y: 35 Bar (508 PSI)
External Pilot Drain P, A, B, T, X: 350 Bar (5075 PSI); Y: 35 Bar (508 PSI)
Fluid
Hydraulic oil as per DIN 51524...51535, other on request
Fluid Temperature
-20°C to +60°C (-4°F to +140°F)
Viscosity Permitted
Recommended
20 to 380 cSt / mm
2
/s (93 to 1761 SSU)
30 to 80 cSt / mm
2
/s (139 to 371 SSU)
Filtration
ISO Class 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
Nominal Flow
at ∆p=5 Bar (72.5 PSI)
per control edge
1)
LPM (GPM)
120 (32) 200 (53) 450 (119) 1000 (265)
Max. Recommended Flow Std LPM (GPM)
250 (66) 600 (159) 1000 (265) 3000 (794)
Regenerative B-A /B-T
Depending on application, see flow curves
Leakage at 100 Bar (1450 PSI)
Overlap Spool
LPM (GPM)
0.2 (0.05)
0.2 (0.05)
0.6 (0.16)
1 (0.26)
Zerolap Spool LPM (GPM)
0.9 (0.24) 0.9 (0.24) 1 (0.26) —
Pilot LPM (GPM)
< 1 LPM (0.26 GPM)
Pilot Supply Pressure
20 Bar (290 PSI) to 350 Bar (5075 PSI)
Pilot Flow, Step Response
at 210 Bar (3045 PSI)
LPM (GPM)
10 (2.6) 12 (3.2) 24 (6.3) 40 (10.6)
Static / Dynamic
Step Response at 100% Stroke
2)
10 ms 13 ms 19 ms 45 ms
Frequency Response
± 5% at 210 Bar (3045 PSI)
Amplitude
Phase
28 Hz
118 HZ
95 Hz
95 Hz
95 Hz
90 Hz
40 Hz
75 Hz
Hysteresis
< 0.1%
Sensitivity
< 0.05%
Temperature Drift
< 0.025%
Electrical
Duty Ratio
100% ED; CAUTION: Coil temperature up to 150°C (302°F) possible
Protection Class
IP65 in accordance with EN 60529 (plugged and mounted)
Supply Voltage / Ripple
22...30V, ripple < 0.5% eff., surge free
Current Consumption
3.5 A maximum
Input Signal Voltage
+10...0...-10V, ripple < 0.01% eff., surge free, 0...+10V P→A
Impedance
100k Ohm
Current
4...12...20 mA, ripple < 0.01% eff., surge free, 12...20 mA P→A
< 3.6 mA = enable off, > 3.8 mA = enable on acc. NAMUR NE43
Impedance
250 Ohm
Input Capacitance
1 nF, typical
Differential Input Maximum
Code 0
Code 5
Code 7
30V for terminal D and E against PE (terminal G)
11V for terminal D and E against 0V (terminal B)
30V for terminal 4 and 5 against PE (terminal W)
11V for terminal 4 and 5 against 0V (terminal 2)
30V for terminal D and E against PE (terminal G)
Enable Signal Code 5 / 7
5...30V, Ri = 9 kOhm
Diagnostic Signal
+10...0...-10V / +Ub, rated maximum 5 mA
Pre-fusing
4.0 A medium lag
EMC
EN 61000-6-2, EN 61000-6-4
Electrical Connection
Code 0 / 7
Code 5
6 + PE acc. EN 175201-804
11 + PE acc. EN 175201-804
Wiring Min. Code 0 / 7
Code 5
mm
2
mm
2
7 x 1.0 (AWG16) overall braid shield
11 x 1.0 (AWG20) overall braid shield
Wiring Length
50m (164 ft.) maximum
1)
Flow rate for different ∆p per control edge:
Q
x
= Q
Nom.
·
√
∆p
x
∆p
Nom.
2)
Measured with load 210 Bar (3045 PSI)
pressure drop; two control edges
D_1FP.indd, ddp
Specifications