Pilot Operated Proportional DC Valve
Series D*1FE
3-74
D_1FE UK.INDD RH 01.09.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
3
General
Design Proportional directional control valve, pilot operated
Actuation VCD®-actuator
Size
NG10 (CETOP 05) NG16 (CETOP 07) NG25 (CETOP 08) NG32 (CETOP 10)
D31 D41 D81 / D91 D111
Mounting Interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTF
D
value [years] 50
Weight [kg] 11.3 14.2 23.5 64.5
Vibration resistance [g]
10 Sinus 5...2000 Hz acc. IEC 68-2-6
30 Random noise 20...2000 Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27
Hydraulic
Max. operating pressure [bar]
Internal Pilot Drain P, A, B, X 350; T, Y 35
External Pilot Drain P, A, B, T, X 350; Y 35
Fluid Hydraulic oil acc. DIN 51524...535, other on request
Fluid temperature [°C] -20...+60
Viscosity permitted [cSt] /
recommended [cSt] /
[mm2/s]
[mm2/s]
20...380
30...80
Filtration ISO 4406 (1999) 18/16/13 (meet NAS 1638: 7)
Nominal flow at Dp = 5 bar per control edge
1)
[l/min] 120 200 400/450 1000
Max. recommended Flow (Standard) [l/min] 250 600 1000 3000
Regenerative B-A / B-T depending on application, see flow curves
Leakage at 100 bar [ml/min] 200 200 600 1000
Pilot [ml/min] < 100
Pilot supply pressure [bar] 20...350
Pilot flow, during step response at 210 bar [l/min] 9 10 18 30
Static / Dynamic
Step response at 100% stroke
2)
[ms] 13 19 24 60
Frequency response
Amplitude ±5 % at 210 bar
Phase ±5 % at 210 bar
[Hz]
[Hz]
180
130
80
100
65
75
38
64
Hysteresis [%] < 0.1
Sensitivity [%] < 0.05
Temperature drift of Center Position [%/K] < 0.025
Electrical
Duty ratio [%] 100
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage / ripple [V] 22...30, ripple < 5% eff., surge free
Current consumption max. [A] 3.5
Pre-fusing [A] 4.0 A medium lag
Input signal Code K (B) voltage
Impedance
[V]
[kOhm]
+10...0...-10, ripple < 0.01 % eff., surge free, 0...+10V P–>A (P–>B)
100
Code E voltage
Impedance
[mA]
[Ohm]
+20...0...-20, ripple < 0.01 % eff., surge free, 0...+20mA P–>B
250
Code S current
Impedance
[mA]
[Ohm]
4...12...20, ripple < 0.01 % eff., surge free, 12...20 mA P–>A
250
< 3.6 mA = enable off, > 3.8 mA = enable on acc. NAMUR NE43
Input Capacitance typ. [nF] 1
Differential input max. Code 0 [V] 30 for terminal D and E against PE (terminal G)
11 for terminal D and E against 0V (terminal B)
Code 5 [V]
30 for terminal 4 and 5 against PE (terminal W )
11 for terminal 4 and 5 against 0V (terminal 2)
Code 7 [V] 30 for terminal D and E against PE (terminal G)
Enable signal Code 5/7 [V] 5...30, Ri = 9 kOhm
Diagnostic signal [V] +10...0...-10 / +Ub, rated max. 5 mA
EMC EN 61000-6-2, EN 61000-6-4
Electrical connection Code 0/7 6 + PE acc. EN 175201-804
Code 5 11 + PE acc. EN 175201-804
Wiring min. Code 0/7 7 x 1.0 AWG16 overall braid shield
Code 5 8 x 1.0 AWG16 overall braid shield
Wiring lenght max. [m] 50
Technical Data
1)
Flow rate for different Dp per control edge:
2)
Measured with load (210 bar pressure drop/two control edges)
Q
x
= Q
Nom.
·
√
Dp
x
Dp
Nom.