3-41
Pilot Operated Proportional DC Valve
Series D*1FB
D_1FB UK.INDD RH 06.09.11
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
3
Technical Data
General
Design Pilot operated DC valve
Actuation Proportional solenoid
Size NG10 (CETOP05) NG16 (CETOP07) NG25 (CETOP08) NG32 (CETOP10)
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position unrestriced
Ambient temperature [°C] -20...+60
MTTF
D
value (OBE) [years] 75 (50)
Weight (OBE) [kg] 8.6 (9.3) 11.9 (12.6) 20.4 (21.1) 68 (68.7)
Vibration resistance [g]
10Sinus 5...200Hz acc. IEC 68-2-6
30 Random noise 20...20Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27
Hydraulic
Max. operating pressure
[bar]
[bar]
Pilot drain internal: P, A, B, X 350; T, Y 185 (NG10: T, Y 15)
Pilot drain external: P, A, B, T, X 350; Y 185 (NG10: Y 15)
Fluid Hydraulic oil as per DIN 51524...535, other on request
Fluid temperature [°C] -20...+60
Viscosity permitted [cSt] /
recommended [cSt] /
[mm
2
/s]
[mm
2
/s]
20...380
30...80
Filtration ISO 4406 (1999) 18/16/13 (meet NAS 1638: 7)
Nominal flow
at Dp=5 bar per control edge * [l/min] 75/90/120 130/200 250/400 1000
Leakage at 100 bar [ml/min] 100 200 600 1000
Pilot supply pressure
[bar]
[bar]
[bar]
min. 30 (+ T/Y pressure)
max. 350
optimal dynamics at 50
Pilot flow at 100bar [l/min] <0.5 <1.2 <1.2 <1.2
Pilot flow, step response [l/min] 2.0 1.9 4.5 18
Static / Dynamic
Step response at 100% step [ms] 50 75 100 180
Hysteresis [%] <5
Electrical characteristics
Duty ratio [%] 100
Protection class
Standard (as per EN175301-803) IP65 in accordance with EN 60529
DT04-2P "Deutsch" IP69K (with correctly mounted plug-in connector)
Solenoid Code K J
Supply voltage [V] 12 24
Current consumption [A] 2.5 1.1
Resistance [Ohm] 4.4 18.6
Coil insulation class F (155 °C)
Solenoid connection
Connector as per EN 175301-803 (code W),
DT04-2P "Deutsch" connector (code J). Solenoid identification as per ISO 9461.
Wiring min. [mm²] 3x1.5 (AWG 16) overall braid shield
Wiring lenght max. [m] 50
Electrical monitor switch
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Ambient temperature [°C] 0-70
Supply voltage/ripple [V] 18...42, ripple <10% eff.
Current consumption without load [mA] <30
Max. output current per channel,
ohmic
[mA] 400
Min. output load per channel, ohmic [kOhm] 100
Max. output drop at 0.2A
Max. output drop at 0.4A
[V]
[V]
<1.1
<1.6
EMV EN 61000-6-2 / EN 61000-6-4
Max. tol. ambient field strength [A/m] 1200
Min. distance to next AC solenoid [m] 0.1
Interface 4+PE acc. IEC 61076-2-101 (M12)
Wiring min. [mm²] 5x0.5 (AWG 20) overall braid shield
Wiring lenght max. [m] 50
* Flow rate for different Dp per control edge: Q
x
= Q
Nom.
·
√
Dp
x
Dp
Nom.