5-21
DURL_UK.INDD CM_26.10.2009
Catalogue HY11-3500/UK
2 Way Proportional Flow Control Valve
Series DUR*L06
Parker Hannifin GmbH
Hydraulic Controls Division
Kaarst, Germany
5
Characteristics
Proportional flow control valves of the series DUR*L06
are used to generate pressure-compensated flow from
A to B. The valve is equipped with a built-in check valve
for the return flow.
For meter-in and meter-out control of an actuator a recti-
fier plate can be used.
Function
When solenoid current is applied, the metering spool
opens against the reset spring and the flow is regulated
by the pressure compensating spool to port B.
With the aid of the pressure compensating spool, the
pressure drop is held constant on the metering window.
Thus pressure load changes are compensated, and the
oil flow remains constant.
In combination with the digital electronic module PC-
D00A-400 the valve parameters can be saved changed
and duplicated.
Technical features
• Lowhysteresis
• Highreproducibility
• Load-independentoilow
• Bypasscheckvalve
• MountingpatterntoISO6263
• 5owrates
Note
Rectifier plate and subplates see ‘Accessories’ at the end
of this chapter.
Design Electrically adjustable orifice valve with load sensing
Mounting type SubplateNG06,InterfaceDIN24340,ISO,CETOP
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -20°C...+50
MTTF
D
value [years] 150
Weight [kg] 1.6
Type of voltage [V] 24
Solenoidnominalcurrent [mA] 680
Duty cycle 100% ED
Solenoidconnection Connector as per EN 175301-803
Protection class IP 65 in accordance with EH60529 (plugged amd mounted)
Amplifier module PCD00A-400
Operatingpressure [bar] Max. 210
Fluid Hydraulic oil according to DIN 51524/525
Fluid temperature [°C] +20 up to max. +70
Viscosityrange [cSt]/ [mm²/s] 12...230
Filtration ISO4406(1999);18/16/13
Min. pressure difference [bar] DUR1.6/3.2:3;DUR6.3/12:5;DUR18:8
Hysteresis at Q
nom
[%] 6
Hysteresis at Q 20%•Q
nom
[%] 6
Repeatability at U
set
= 5V [%] 2
Technical data
5-22
DURL_UK.INDD CM_26.10.2009
Catalogue HY11-3500/UK
2 Way Proportional Flow Control Valve
Series DUR*L06
Parker Hannifin GmbH
Hydraulic Controls Division
Kaarst, Germany
5
Ordering Code / Performance Curves
Size
NG06
2 way flow
control valve
with bypass
check valvel
Nominal
flow
Linear
solenoid
L
Seal Design
series
DUR 06 P
Progressive
performance
curve
Solenoid
(not required
for ordering)
Seal kits
NBR FPM
SK-DUR***L SK-DUR***LFPM
Performance curves
DUR 1.6 L 06 PK*
DUR 3.2 L 06 PK* / DUR 6.3 L 06 PK*
DUR 12 L 06 PK* / DUR 18 L 06 PK*
K
Ordering code
Code Flow [l/min]
1,6 1.6
3,2 3.2
6,3 6.3
12 12.0
18 18.0
Code Seal
A NBR
1 FPM
Flow Q [l/min]
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
Solenoid current [%]
020406080 100
Flow Q [l/min]
8
7
6
5
4
3
2
1
0
Solenoid current [%]
020406080 100
20
18
16
14
12
10
8
6
4
2
0
Flow Q [l/min]
Solenoid current [%]
020406080 100
All characteristic curves measured with HLP46 at 50°C.
5-23
DURL_UK.INDD CM_26.10.2009
Catalogue HY11-3500/UK
2 Way Proportional Flow Control Valve
Series DUR*L06
Parker Hannifin GmbH
Hydraulic Controls Division
Kaarst, Germany
5
Dimensions
Dimensions
5-24
DURL_UK.INDD CM_26.10.2009
Catalogue HY11-3500/UK
2 Way Proportional Flow Control Valve
Series DUR*L06
Parker Hannifin GmbH
Hydraulic Controls Division
Kaarst, Germany
5
Accessories
Measured with HLP46 at 50°C.
Sandwich rectifier plate
If a 2 way flow control valve is used in combination with
a rectifier plate the valve can be used for meter-in and
meter-out flow control of an actuator.
Design
The intermediate rectifier plate is designed with 4 identi-
cal, symmetrically arranged check valves. Thus the dif-
ferential pressure is the same in both flow directions.
Dimension tolerances
* : ± 0.1mm
others : ± 0.2 mm
holes and silhouette of
valve body : untoleranced dimension
Ordering code: HROA06C
Dimensions
Connections Dimensions required units
A, B 12 x 1.5 2
Ordering code
SPD22B910 P, A, B and T = G1/4
SPD23B910 P, A, B and T = G1/8
O-ring for sealing the connecting surface
(not included)
Subplates
1)
1)
Detailsseechapter12,seriesSPD