5-21
DURL_UK.INDD CM_26.10.2009
Catalogue HY11-3500/UK
2 Way Proportional Flow Control Valve
Series DUR*L06
Parker Hannifin GmbH
Hydraulic Controls Division
Kaarst, Germany
5
Characteristics
Proportional flow control valves of the series DUR*L06
are used to generate pressure-compensated flow from
A to B. The valve is equipped with a built-in check valve
for the return flow.
For meter-in and meter-out control of an actuator a recti-
fier plate can be used.
Function
When solenoid current is applied, the metering spool
opens against the reset spring and the flow is regulated
by the pressure compensating spool to port B.
With the aid of the pressure compensating spool, the
pressure drop is held constant on the metering window.
Thus pressure load changes are compensated, and the
oil flow remains constant.
In combination with the digital electronic module PC-
D00A-400 the valve parameters can be saved changed
and duplicated.
Technical features
• Lowhysteresis
• Highreproducibility
• Load-independentoilow
• Bypasscheckvalve
• MountingpatterntoISO6263
• 5owrates
Note
Rectifier plate and subplates see ‘Accessories’ at the end
of this chapter.
Design Electrically adjustable orifice valve with load sensing
Mounting type SubplateNG06,InterfaceDIN24340,ISO,CETOP
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -20°C...+50
MTTF
D
value [years] 150
Weight [kg] 1.6
Type of voltage [V] 24
Solenoidnominalcurrent [mA] 680
Duty cycle 100% ED
Solenoidconnection Connector as per EN 175301-803
Protection class IP 65 in accordance with EH60529 (plugged amd mounted)
Amplifier module PCD00A-400
Operatingpressure [bar] Max. 210
Fluid Hydraulic oil according to DIN 51524/525
Fluid temperature [°C] +20 up to max. +70
Viscosityrange [cSt]/ [mm²/s] 12...230
Filtration ISO4406(1999);18/16/13
Min. pressure difference [bar] DUR1.6/3.2:3;DUR6.3/12:5;DUR18:8
Hysteresis at Q
nom
[%] 6
Hysteresis at Q ≤20%•Q
nom
[%] 6
Repeatability at ∆U
set
= 5V [%] 2
Technical data