D1FV UK.INDD RH 06.09.11
3-53
Proportional Pressure Reducing Valve
Series D1FV
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
3
D1FV*3 OBE
D1FV D1FV OBE
The proportional pressure reducing valves series D1FV
are available with and without onboard electronics (OBE).
D1FV OBE
The digital onboard electronics is situated in a robust
metal housing, which allows the usage under rough en-
vironmental conditions.
The nominal values are factory set. The cable for connec-
tion to a serial RS232 interface is available as accessory.
D1FV for external electronics
The parameters can be saved, changed and duplicated in
combination with the digital power amplifier PWD00A-400.
The value parameters can be edited with the common
ProPxD software for both versions.
The D1FV values control the pressure in the A- or B-ports
using the barometric feedback principle.
Technical Features
Barometric feedback
3 command options for D1FV OBE: ±10V, 4...20mA,
±20mA
High repeatability from valve to valve
Low hysteresis
Manual override
Pressure stages 25 bar and 45 bar
Parametrizing connection
Main connection
(always on B-side)
Characteristics
T
T
T
T
P
P
B
B
a
A
A
P
T
T
T
T
P
P
B
B
b
A
A
P
T
T
T
T
P
P
B
B
b
A
A
P
a
Function C
Function K
Function E
D1FV UK.INDD RH 06.09.11
3-54
Proportional Pressure Reducing Valve
Series D1FV
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
3
Size
DIN NG06
CETOP 03
NFPA D03
Ordering Code
Proportional
control
Seals Solenoid
12V / 2.2A
* Please order connector separately.
See chapter 3 accessories.
Control
function
Connector
D1FV
Code Pressure range
C 25 bar
D 45 bar
Code Control function
C
E
K
Spool/
body
design
Design
series
(not required
for ordering)
Spool
type
Pressure
range
Proportional
pressure
reducing
valve
Code Connector
W*
Connector as per EN
175301-803
J*
Connector
DT04-2P "Deutsch"
VF1D E02 0 K 3
Code Seals
N NBR
V FPM
D1FV UK.INDD RH 06.09.11
3-55
Proportional Pressure Reducing Valve
Series D1FV
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
3
D1FB_UK.INDD CM 06.09.2011
Ordering Code
Size
DIN NG06
CETOP 03
NFPA D03
Directional
control
valve
Proportional
control
Control
function
Please order connector separately.
See chapter 3 accessories.
Parametrizing cable OBE ® RS232
Item no. 40982923
Spool position
Code Input signal
1)
Function Port Options
F0
0...+/-10V 0...+10V > P-A 6 + PE
Potentiometer
supply
G0
0...+/-20mA 0...+20mA > P-A 6 + PE
M0
0...+/-10V 0...+10V > P-B 6 + PE
Potentiometer
supply
S0
4...20mA 12...20mA > P-A 6 + PE
W5
2)
0...+/-10V
4...20mA
0...+/-20mA
0...+10V > P-A
12...20mA > P-A
0...+20mA > P-A
11 + PE
Potentiometer
supply & com-
mand preset
channel
Code Control function
C
E
K
Electronic
attachment
Design
series
(not required
for ordering)
Input
signal
D1FV OBE (with onboard electronics)
1)
Single solenoid always 0...+10V respectively 4...20mA
2)
Factory set ±10V on delivery
Pressure
range
Spool
type
Seals Spool/
body
design
Code Pressure range
C 25 bar
D 45 bar
OBE
VF1D E02 0 3
Code Seals
N NBR
V FPM
D1FV UK.INDD RH 06.09.11
3-56
Proportional Pressure Reducing Valve
Series D1FV
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
3
Technical Data
General
Design Direct operated proportional pressure reducing valve
Actuation Proportional solenoid
Size NG06/CETOP 03/NFPA D03
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position unrestricted
Ambient temperature [°C] -20...+40
MTTF
D
value (OBE) [years] 150 (75)
Weight (OBE) [kg] 2.2 (2.9)
Vibration resistance [g]
10 Sinus 5...2000 Hz acc. IEC 68-2-6
30 Random noise 20...2000 Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27
Hydraulic
Max. operating pressure [bar] Ports P, A, B 350; Port T 185
Max. pressure drop PABT / PBAT [bar] 350
Fluid Hydraulic oil as per DIN 51524...535, other on request
Fluid temperature [°C] -20...+40
Viscosity permitted [cSt] /
recommended [cSt] /
[mm
2
/s]
[mm
2
/s]
20...380
30...80
Filtration ISO 4406 (1999) 18/16/13 (meet NAS 1638: 7)
Max. flow [l/min] 10
Min. primary pressure [bar] 30
Static / Dynamic
Hysteresis [%] <4
Temperature drift solenoid current [%/K] <0.02
Electrical characteristics
Duty ratio [%] 100
Protection class
Standard (as per EN175301-803) IP65 in accordance with EN60529 (with correctly mounted
plug-in connector); DT04-2P “Deutsch“ IP69K (with correctly mounted plug-in connector)
Supply voltage [V] 12
Current consumption [A] 2.2
Resistance [Ohm] 4.4
Coil insulation class F (155 °C)
Solenoid connection
Connector as per EN 175301-803 (code W), DT04-2P “Deutsch“ connector (code J).
Solenoid identification as per ISO 9461.
Wiring min. [mm²] 3x1.5 (AWG 16) overall braid shield (code W), "Deutsch" connector DP4 2 Pin (code J)
Wiring lenght max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
D1FV UK.INDD RH 06.09.11
3-57
Proportional Pressure Reducing Valve
Series D1FV
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
3
OBE
D1FB_UK.INDD CM 06.09.2011
Technical Data / Characteristic Curves
Electrical characteristics OBE
Duty ratio [%] 100
Protection class IP65 in accordance with EN 60529 (plugged and mounted)
Supply voltage/ripple DC [V] 18...30, ripple < 5% eff., surge free
Current consumption max. [A] 2.0
Pre fusing medium lag [A] 2.5
Input signal
Codes F0 & W5
voltage [V] +10...0...-10, ripple < 0.01 % eff., surge free, Ri = 100kOhm, 0...+10V Þ P -> A
Codes M0
voltage [V] +10...0...-10, ripple < 0.01 % eff., surge free, Ri = 100kOhm, 0...+10V Þ P -> B
Codes S0 & W5
current
[mA] 4...12...20, ripple < 0.01 % eff., surge free, Ri = 200Ohm, 12...20mA Þ P -> A
< 3.6 mA = enable off,
> 3.8 mA = enable on (acc. to NAMUR NE43)
Code G0 [mA] +20...0...-20, ripple < 0.01 % eff., surge free, Ri = 200Ohm, 0...+20mA Þ P -> A
Differential input max.
Codes F0, G0, M0 & S0 [V]
30 for terminal D and E against PE (terminal G)
11 for terminal D and E against 0V (terminal B)
Code W5 [V]
30 for terminal 4 and 5 against PE (terminal PE)
11 for terminal 4 and 5 against 0V (terminal 2)
Channel recall signal [V] 0...2.5: off / 5...30: on / Ri = 100 kOhm
Min [%] 0...50
Adjustment ranges Max [%] 50...100
Ramp [s] 0...32.5
Interface RS 232, parametrizing connection 5pole
EMC EN 61000-6-2, EN 61000-6-4
Central connection
Codes F0, G0, M0 & S0
Code W5
6 + PE acc. to EN 175201-804
11 + PE acc. to EN 175201-804
Wiring min.
Codes F0, G0, M0 & S0
Code W5
[mm²]
[mm²]
7 x 1.0 (AWG16) overall braid shield
11 x 1.0 (AWG16) overall braid shield
Wiring length max. 50
Flow characteristics
All characteristic curves measured with HLP46 at 50°C.
0 2 4 6 8 10
50
40
30
20
10
0
Flow [l/min]
A-T / B-T
P-A / P-B
Pressure drop p [bar]
D1FV UK.INDD RH 06.09.11
3-58
Proportional Pressure Reducing Valve
Series D1FV
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
3
Block Diagrams
OBE
Code W5
11 + PE acc. to EN 175201-804
Code F0
6 + PE acc. to EN 175201-804
Code G0, S0
6 + PE acc. to EN 175201-804
D1FV UK.INDD RH 06.09.11
3-59
Proportional Pressure Reducing Valve
Series D1FV
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
3
Interface Program
ProPxD interface program
The ProPxD software permits comfortable parameter
setting for the module electronics. Via the clearly arranged
entry mask the parameters can be noticed and modified.
Storage of complete parameter sets is possible as well
as printout or record as a text file for further documenta-
tion. Stored parameter sets may be loaded anytime and
transmitted to other valves. Inside the electronics a non-
volatile memory stores the data with the option for recal-
ling or modification.
Features
comfortable editing of all parameters
depiction and documentation of parameter sets
storage and loading of optimized parameter adjust-
ments
executable with all actual Windows ® operating sy-
stems from Windows ® 95 upwards
plain communication between PC and electronics via
serial interface RS232C.
comfortable PC user software, free of change:
www.parker.com/euro_hcd
– see "Support"
The parametrizing cable may be ordered under item no.
40982923.
OBE
D1FV UK.INDD RH 06.09.11
3-60
Proportional Pressure Reducing Valve
Series D1FV
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
3
Dimensions
Surface finish
NBR
BK375
4x M5x30
DIN 912 12.9
7.6 Nm
±15%
SK-D1FB-N
D1FV*C
D1FV*E
67,5
1585
19,4
46
B A
T
P
BTA
222
76,7
72,5
19,4
72,5 76,70
167
46
B A
T
P
85
15
~53
BTA
19,4
72,576,70
167
B A
T
P
85
15
BTA
46
~53
D1FV*K
D1FV UK.INDD RH 06.09.11
3-61
Proportional Pressure Reducing Valve
Series D1FV
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
3
Dimensions
D1FV*C OBE
D1FV*E OBE
Surface finish
NBR
BK375
4x M5x30
DIN 912 12.9
7.6 Nm
±15%
SK-D1FB-N
BTA
221
46
125
72
19,4
Ø9,5
Ø5,5
22
B A
T
P
76,7
BTA
166
125
72
19,4
Ø9,5
Ø5,5
22
B A
T
P
46
76,7
BTA
166
46
125
72
19,4
Ø9,5
Ø5,5
22
B A
T
P
76,7
D1FV*K OBE
D1FV UK.INDD RH 06.09.11
3-62
Proportional Pressure Reducing Valve
Series D1FV
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
3
Dimensions
Dimensions with DT04-2P "Deutsch" connector
D1FV*C
19,4
46
B A
T
P
BTA
222
76,7
72,5
19,4
B A
T
P
BTA
167
76,7
46
~53
67,5
72,5
19,4
B A
T
P
BTA
167
76,7
46
~53
67,5
72,5
D1FV*E D1FV*K
Surface finish
NBR
BK375
4x M5x30
DIN 912 12.9
7.6 Nm
±15%
SK-D1FB-N