Technical Data
1)
Flow rate for different ∆p per control edge: Q
x
= Q
Nom.
·
√
∆p
x
∆p
Nom.
2)
Inverse polarity on request
General
Design Direct-operated DC Valve with onboard electronics
Actuation Proportional solenoid
Size NG6 (CETOP 3)
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position Any
Ambient temperature [°C] -20...+60
Weight [kg] 1.9
Hydraulic
Max. operating pressure [bar] Ports P, A, B, T, X max. 350; Port Y max. 50
Fluid Hydraulic oil as per DIN 51524...535, other on request
Fluid temperature [°C] -20...+60
Viscosity permitted [mm2/s] 20...380
Viscosity recommended [mm2/s] 30...80
Filtration ISO 4406 (1999) 18/16/13 (acc. NAS 1683: 7)
Flow nominal
1)
[l/min] 20
Leakage at 100 bar [ml/min] <200
Static / Dynamic
Step response at 100% step [ms] 90
Hysteresis [%] <8
Electrical characteristics
Duty ratio [%] 100
Protection class IP54
Supply voltage/ripple [V] 14.5 ... 30, ripple <5% eff.
Current consumption max. [A] 2.8
Input signal
2)
Voltage [V] 10...0...-10, ripple <0.01% eff., surge free, 0...+10V P->A
Impedance [kOhm] 100
Current [mA] 20...0...-20, ripple <0.01% eff., surge free, 0...+20mA P->A
Impedance [Ohm] 500
Differential input max. [V] 30 for terminal D and E against PE
Ramp [s] 0...3
Pre-fusing [A] 6.3 medium lag
EMC EN 50081-1 / EN50082-2
Coil insulation class F (155 °C)
Electrical connection 6+PE acc. DIN 43563
Wiring min. [mm²] 7x1.0 (AWG 18) overall braid shield
Wiring lenght max. [m] 50