2
Parker Hannifin
Cylinder Division
Europe
Catalogue HY07-1235/UK
Bladder Accumulators
Series BAE
Introduction
About Parker Hannifin
Parker Hannifin is the global leader in motion and control
technologies, partnering with its customers to increase their
productivity and profitability. The company employs more
than 61,000 people in 48 countries around the world, providing
customers with technical excellence and first class customer
service.
Catalogues describing our standard products are available from
your nearest Parker sales office – please see the rear cover of
this catalogue for addresses. Where an application demands a
non-standard approach, special products can be designed to
order – our engineers will be pleased to advise.
Visit us at www.parker.com
Contents Page
Technical Data 2
Design Features and Benefits 3
Models, Capacities and Dimensions 3
Flow Rates 3
Repair Kits and Parts List 4
Bladder Compounds 5
Port Sizes 5
Fluid Port Adapters 5
Charging and Gauging Assemblies 5
Mounting Accessories 6
Model Numbers 7
How to Order 7
Why use a Bladder Accumulator?
• storesenergyunderpressure
• dampsoutpumppulsationandowuctuations
• improvessystemefciency
• supplementspumpdelivery
• suppliespowerinemergency
• absorbshydraulicshocks
• compensatesforpressurechangesincasesofthermalstress
• verycontaminanttolerant
• suitableforusewithlow-lubricityuids
• fastresponsetimes
• Safety–cannotdisassembleunderpressure
Bladder Accumulators
Liquids are practically incompressible and therefore cannot be
used directly for storing energy. Hydro-pneumatic accumulators
use the differing compressibility of liquid and gaseous media to
enable energy to be stored in liquids under pressure.
Parker's hydro-pneumatic bladder accumulators provide a
means of regulating the performance of a hydraulic system.
Their simple, compact, design ensures dependable
performance, maximum efficiency and long service life.
Technical Data
Standard volumes 1 – 50 litres
Operating pressure Up to 330 bar, with p
2
< 4 x p
1
where p
1
= minimum working pressure
and p
2
= maximum working pressure
Precharge pressure
– energy storage 90% of minimum working pressure
– pulsation dampening 60% of maximum working pressure
– shock suppression 60% of maximum pump pressure
Std. temperature range Shell and ports: -40°C to +80°C
Bladder and seals: -15°C to +80°C
For use at other temperatures, please
consult factory.
Fluid type Mineral oil (standard compounds)
PositioningFromvertical(uidportdownwards)tohorizontal.
A minimum clearance of 200mm must be left above the gas
valve for mounting the charging and gauging assembly – see
page 5.
Warning
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED
ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries, sales offices and authorized distributors provide
product or system options for further investigation by users having technical expertise. Before you select or use any product or system it is
important that you analyse all aspects of your application and review the information concerning the product or system in the current product
catalogue. Due to the variety of operating conditions and applications for these products or systems, the user, through his own analysis
and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance and safety
requirements of the application are met.
The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to
change by Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
Please contact you local Parker representative for a detailed offer of sale.