Parker Hannifin Corporation
Hydraulic Cartridge Systems
Technical Information
Specifications
General Description
Pilot Operated Sequence Valve with Reverse Flow
Check. For additional information see Technical Tips
on pages PC1-PC6.
Features
•
High flow capacity
•
For use on clamp and drill circuits where pressure is to be
maintained regardless of drop in system pressure
•
Integral 250 micron pilot flow filter
•
Hardened working parts for maximum durability
•
Adjustable and tamperproof versions available
•
All external parts zinc plated
Rated Flow 70 LPM (18.5 GPM)
Maximum Inlet 420 Bar (6000 PSI)
Pressure
Maximum H - 10-210 Bar (145-3000 PSI)
Pressure Setting P - 10-420 Bar (145-6000 PSI)
Maximum Tank 420 Bar (6000 PSI)
Pressure
Leakage at 50 drops/min.
150 SSU (32 cSt) @ 100 Bar (1450 PSI)
Cartridge Material All parts steel. All operating
parts hardened steel.
Operating Temp. -40°C to +93.3°C (Nitrile)
Range/Seals (-40°F to +200°F)
-31.7°C to +121.1°C (Fluorocarbon)
(-25°F to +250°F)
Fluid Mineral-based or synthetic with
Compatibility/ lubricating properties at viscosities
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
Filtration ISO Code 16/13,
SAE Class 4 or better
Approx. Weight 0.25 kg (0.55 lbs.)
Cavity C10-3S
(See BC Section for more details)
Form Tool Rougher NFT10S-3R
Finisher NFT10S-3F
Performance Curve
(Pressure rise through cartridge only)
Application
(2)
(3)
(1)
(2)
(3)
(1)
Flow (Q)
80
21.2
100
26.5
0
40
10.6
20
5.3
60
15.9
LPM
GPM
120
31.7
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
0
1450
300
400
200
100
Pressure Drop
4350
5800
PSI Bar
2900
Flow vs. Inlet Pressure 1 to 2
FREE FLOW 2 to 1
Drill
Clamp
NOTE: Drain line should be piped
directly back to tank. Any back
pressure in the drain line will be
additive to the sequence pressure.