Catalog HY15-3501/US
Parker Hannifin Corporation
Hydraulic Cartridge Systems
Check
Valves
Shuttle
Valves
Load/Motor
Controls
Flow
Controls
Pressure
Controls
Logic
Elements
Directional
Controls
Manual
Valves
Solenoid
Valves
Proportional
Valves
Coils &
Electronics
Bodies &
Cavities
Technical
Data
SH
CV
LM
FC
PC
LE
DC
MV
SV
PV
CE
BC
TD
PV21
Proportional Relief Valve
Series AP04G2YR 10C, 21C, 35CTechnical Information
Specifications
Rated Flow 95 LPM (25 GPM)
(At 300 PSI
∆∆
∆∆
∆P)
When Coil is Fully
Energized
Factory Set Relief 10C 103 Bar (1500 PSI)
Pressure When 21C 210 Bar (3000 PSI)
Coil De-Energized 35C 350 Bar (5000 PSI)
Measured at
45 LPM (12 GPM)
Hysteresis @ < 7%
250 Hz PWM of Maximum Pressure Setting
Response Time At To Unload 45ms
75% of Nominal To Load 25ms
Voltage Change
(Measured To 90%
of Press. Change)
Cartridge Material All parts steel. All operating
parts hardened steel.
Operating Temp. -40°C to +93.3°C (Nitrile)
Range/Seals (-40°F to +200°F)
-31.7°C to +121.1°C (Fluorocarbon)
(-25°F to +250°F)
Fluid Mineral-based or synthetic with
Compatibility/ lubricating properties at viscosities
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
Filtration ISO Code 16/13,
SAE Class 4 or better
Approx. Weight .14 kg (.30 lbs.)
Cavity C10-2
(See BC Section for more details)
General Description
Proportional Relief Valve. Decreasing Pressure With
Increasing Current. For additional information see
Technical Tips on pages PV1-PV6.
Features
•
Pilot operated spool-type design
•
Precise setting of factory preset pressure in de-energized
mode
•
One piece cartridge housing ensures internal
concentricity
•
Coil: Waterproof, hermetically sealed, requires no
O’Rings; Symmetrical coil can be reversed without
affecting performance.
•
All external parts zinc plated
Performance Curves
PWM Current Regulator Recommended
(1)
(2)
(1)
(2)
Flow (Q)
76
20
19
5
38
10
57
15
LPM
GPM
0
95
25
0
2000
1000
300
205
137
68
21
3000
5000 345
2744000
PSI Bar
Relief Pressure
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
Relief Performance
-35
-21
-10
Coil Fully Energized
Coil De-Energized
-35
-21
-10
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
0
1000
5000 345
205
274
137
68
Pressure
3000
4000
PSI Bar
2000
Input Current (%)
19 38
0
57 75
Pressure vs. Input Current