PV11
Proportional Relief Valve
Series AP04G2YP 10C, 21C, 35CTechnical Information
Specifications
Rated Flow 95 LPM (25 GPM)
(At 300 PSI
∆∆
∆∆
∆P)
When Coil is Fully
De-Energized
Factory Set Relief 10C 103 Bar (1500 PSI)
Pressure When 21C 210 Bar (3000 PSI)
Coil De-Energized 35C 350 Bar (5000 PSI)
Measured at
45 LPM (12 GPM)
Hysteresis @ < 7%
250 Hz PWM of Maximum Pressure Setting
Response Time At To Unload 10ms
75% of Nominal To Load
Voltage Change 10C 45 ms
(Measured To 90% 21C 60 ms
of Press. Change) 35C 80 ms
Cartridge Material All parts steel. All operating
parts hardened steel.
Operating Temp. -40°C to +93.3°C (Nitrile)
Range/Seals (-40°F to +200°F)
-31.7°C to +121.1°C (Fluorocarbon)
(-25°F to +250°F)
Fluid Mineral-based or synthetic with
Compatibility/ lubricating properties at viscosities
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
Filtration ISO Code 16/13,
SAE Class 4 or better
Approx. Weight .14 kg (.31 lbs.)
Cavity C10-2
(See BC Section for more details)
General Description
Proportional Relief Valve. Increasing Pressure With
Increasing Current. For additional information see
Technical Tips on pages PV1-PV6.
Features
•
Pilot operated spool-type design fits industry common
cavity (10-2)
•
Relieving pressure output is proportional to DC current
input
•
Precise setting of factory preset pressure in energized
mode
•
One piece cartridge housing ensures internal
concentricity
•
Coil: Waterproof, hermetically sealed, requires no
O’Rings; Symmetrical coil can be reversed without
affecting performance.
•
All external parts zinc plated
Performance Curves
PWM Current Regulator Recommended
(1)
(2)
(1)
(2)
Flow (Q)
76
20
19
5
38
10
57
15
LPM
GPM
0
95
25
0
2000
1000
300
205
137
68
21
3000
5000 345
2744000
PSI Bar
Pressure Drop ( P)
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
Relief Performance
-35
-21
-10
Coil De-Energized
Coil Fully Energized
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
0
1000
5000 345
205
274
137
68
Pressure
3000
4000
PSI Bar
2000
Current, Amp
.30
.15
12V
24V
.60
.30
0
.90
.45
1.20
.60
Pressure vs. Input Current
-35
-21
-10
Measured at coil stabilized
temperature and nominal flow