59
9660/61/64 SERIES
6000 PSI/150 GPM
FOR TECHNICAL ASSISTANCE CALL TOLL FREE 1-888-333-PALL (7255) ©Copyright 1998, 2000, Pall Corporation. All rights reserved.
Assembly P/N: H 966
TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6 TABLE 7 TABLE 8 TABLE 9 TABLE 10
Element P/N:
HC 960 F
TABLE 2 TABLE 5 TABLE 6 TABLE 1
Ordering Information
Table 1. Seal Options
Code Seals
H Nitrile
Z Fluorocarbon
Table 2. Element Options
Code Rating
0 290 psid (std.)
1 3000 psid
(high collapse)
4 150 psid
(coreless)
Table 3. Port Style Options Table 4. Port Size OptionsTable 1. Seal Options
Code Seals
H Nitrile
Z Fluorocarbon
Table 2. Element Options
Code Rating
0 290 psid (std.)
1 3000 psid
(high collapse)
4 150 psid
(coreless)
Table 3. Port Style Options
Code Port Style
A SAE J514 straight thread
B NPT
D Flange SAE J518c-code 61
E Flange SAE J518c-code 62
K Manifold mount (9660/61 only)
Table 4. Port Size Options
Code Size Style Availability
16 1" A,D,E
20 1
1
⁄4" A,D,E
24 1
1
⁄2" A,B,D,K
See page 140.
*9661 only.
See page 17 for filter specifications.
Table 5. Filter Element Options
Code β
x
≥200 β
x(c)
=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
DP* 3 5
DT* 17 15
Assembly Element
Code Code**
R*** 4
S8
T13
U16
* Use code in second column
for element part no.
** Nominal length in inches
***Not available for 9664.
* Not available for 9664
Table 6. Length Options* Table 7. Bypass Valve Options
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal
lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M ‘T’ type switch with matching wiring
cap
S Electrical switch with MS receptacle
V Combined visual/electrical
with DIN connector
B Bleed plug and seal in place of
indicator
2 ‘P’ and ‘L’
3 ‘P’ and ‘S’
Table 8. Differential Pressure Device Options
Code Description
B 50 psid- 9660/64 only
C 50 psid bypass
with reverse flow
(9660/64 only)
W Non bypass-9661 only
K Non bypass with
reverse flow-9661 only
Table 10. Special Options
Code Description
Y411* Heavy duty ‘B’, ‘C’ or ‘K’ valve for
highly cyclic applications
Y151
3
⁄4" mounting bolt holes for ‘K’ head
(
1
⁄2" bolt holes standard)
Table 9. Mounting Bracket Options
Code Description
1 1 mounting bracket
2 2 mounting brackets
– No mounting brackets