Technical data
General specifications
Sensing range 200 ... 1500 mm
Adjustment range 200 ... 1500 mm
Dead band 0 ... 200 mm
Standard target plate 20 mm x 20 mm
Transducer frequency approx. 200 kHz
Nominal ratings
Time delay before availability t
v
250 ms
Limit data
Permissible cable length max. 300 m
Indicators/operating means
LED green Power on
LED yellow solid: switching state switch output
flashing: misadjustment
Electrical specifications
Rated operating voltage U
e
24 V DC
Operating voltage U
B
15 ... 30 V (including ripple)
In supply voltage interval 15 ... 20 V sensitivity reduced to
20% ... 0%
Ripple 10 %
No-load supply current I
0
60 mA
Input
Input type 1 Function input
Input voltage Operating voltage
Level low level : 0 ... 3 V
high level : 15 V
Switching output
Output type 1 switch output PNP, NO
Default setting 200 ... 1500 mm
Operating current I
L
300 mA , short-circuit/overload protected
Voltage drop 3 V
Analog output
Output type 1 current output 4 ... 20 mA , rising ramp
Default setting 200 ... 1500 mm
Linearity error 1.5 %
Load resistor 300
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Shock resistance 30 g , 11 ms period
Vibration resistance 10 ... 55 Hz , Amplitude ± 1 mm
Mechanical specifications
Connection type Connector plug M12 x 1 , 5-pin
Degree of protection IP65
Material
Housing PBT
Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam
Installation position any position
Mass 500 g
Compliance with standards and
directives
Standard conformity
Standards EN 60947-5-2:2007+A1:2012
IEC 60947-5-2:2007 + A1:2012
EN 60947-5-7:2003
IEC 60947-5-7:2003
Approvals and certificates
UL approval cULus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated 36 V
Model Number
UC1500-F65-IE2R2-V15
Features
•Level indication
1 analog output, 4-20 mA current
source
•1 switch output
Programmable by means of
Interface (see accessories) and
SONPROG
Synchronization options
Temperature compensation
Diagrams
Characteristic response curve
Distance X [mm]
Distance Y [mm]
Curve 1: flat surface 100 mm x 100 mm
Curve 2: round bar, Ø 25 mm
400
320
240
160
80
0
-80
-160
-240
-320
-400
0 300 600 900 1200 1500 1800 2100 2400 2700 3000
2
X
Y
1
Ultrasonic sensor UC1500-F65-IE2R2-V15
2
Release date: 2019-06-07 10:24 Date of issue: 2019-06-07 235142_eng.xml
Germany: +49 621 776 1111Pepperl+Fuchs Group
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
fa-info@de.pepperl-fuchs.com
Dimensions
Electrical Connection
Pinout
2 x ø8.8
2 x ø5.5
ø30
10
17
30
6
54
4612
64.4
125
1
+U
B
XI
2
4
5
-U
B
3
Switch output
Analog output
1
3
4
5
2
1 BN
2 WH
3 BU
4 BK
5 GY
Wire colors in accordance with EN 60947-5-2
(brown)
(white)
(blue)
(black)
(gray)
Additional Information
Sensor
Function of the outputs
Sensor
Sensor
Switching
output
Analog-
output
1
0
max.
min.
S
min
S
max
A
E
Ultrasonic sensor UC1500-F65-IE2R2-V15
3
Release date: 2019-06-07 10:24 Date of issue: 2019-06-07 235142_eng.xml
Germany: +49 621 776 1111Pepperl+Fuchs Group
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
fa-info@de.pepperl-fuchs.com
Application ranges
The design and function of this ultrasonic sensor make it ideal for filling level applications in small containers. The device has a switch output and an analogue output. With
the switch output, a specific filling level in a tank can be signalled directly. The analogue output represents the current level as an analogue output variable.
Assembly and connection
All components are contained in an encapsulated housing. The ultrasonic converter is in a slightly recessed position in the housing. The integrated circumferential seal allows
the sensor to be used directly as a closure with integrated filling level measurement. The tank opening must have a diameter of 26 mm. It can be mounted on the tank using
2 M5 screws. The electrical connection is based on a 5-pin device connector, M12 x 1. The connections are protected against reverse polarity, short circuits and overloads.
Shielded cables are recommended if there is electrical interference.
Setting
As delivered, the switch-on and switch-off point, the measuring range limits and the averaging are fixed (see Technical data). They can subsequently be adapted to the appli-
cation via SONPROG using the interface (see Accessories).
SONPROG
The following parameters can be changed via SONPROG:
Measuring range limits S
min
and S
max
Switch-on and switch-off points (A, E)
Blind zone
Averaging
Special programming options are available on request.
Operation
The filling level of a container is detected within the detection range. When the filling level reaches the switch-on or switch-off point (E or A), the switch output reacts according
to its setting. The switching statuses of the switch output are signalled by the yellow LEDs. If the level is between the switching points A and E, the output is active.
Filling levels between the measuring range limits (S
min
, S
max
) are displayed in the form of an analogue output signal at the analogue output. The analogue output delivers its
minimum value at filling level S
min
and its maximum value at filling level S
max
. The characteristic between the two measuring range limits is linear.
Objects in the blind zone cause cause false signals. Install in such a way that the filling level cannot enter the blind zone.
Function input XI
The sensor is placed in standby mode by connecting a low level at the function input XI (blocked release). The sensors then performs no measurements. The outputs retain
the most recent status. As soon as function input XI is disconnected from the low level or a high level is connected (release), the sensor resumes its normal function.
The function input XI can be used during operation for the synchronisation of multiple sensors. This can be done by connecting external signals, e.g. from a controller (external
synchronisation) or by simply connecting the function inputs of all sensors to be synchronised (internal synchronisation).
Accessories
V15-G-2M-PUR
Female cordset, M12, 5-pin, PUR cable
V15-G-2M-PVC
Female cordset, M12, 5-pin, PVC cable
V15-W-2M-PVC
Female cordset, M12, 5-pin, PVC cable
3RX4000-PF